Factory settings
Burner gas output setting
The values shown in the tables below are given for information purposes for a nominal gas distribution pressure, to allow any
adjustments to the boiler heating output according to the requirements of the appliance.
They cannot be used to calculate the precise regulated output of the water heater.
8. Operating (continued)
Pompe Grande Vitesse
Pompe Petite Vitesse
Anticycle 3 min
Fonctionnement Modulant
Tempo Débistat Sanitaire 1,5 sec
Tempo Débistat Sanitaire 0 sec
Célectic
OFF
ON
Anticycle 30 s
Fonctionnement TOUT OU RIEN
Consigne chauffage à 40 C
Consigne chauffage variable de 35 à 85 C
Post circulation 30 s
Post circulation 3 mn
Fig.13
Adaptive speed pump
High speed pump
ON
OFF
ON/OFF operation
Heating setting to 40 °C
Modulating Operation
Adjustable heating setting 35 to 85 °C
30 s anticycle
3 min anticycle
Post-circulation 30 s
Post-circulation 3 min.
24 FF
Gas
G20
PROPANE
BUTANE
Working P.
(kW)
Pressure
plate
(mm CE)
10
25
74
55
12,7
38
117
89
16
57
182
137
20
86
276
204
24
120
390
282
30 FF
Gas
G20
PROPANE
BUTANE
Working P.
(kW)
Pressure
plate
(mm CE)
12
27
69
48
16
43
112
85
20
63
167
131
25
98
254
202
30
140
359
287
TIC 3 min.
TIC 30 sec.