Chaffoteaux & Maury Mira System CF Скачать руководство пользователя страница 12

12

If the equipment has an operating fault, one or more LEDs (

23

) flash according to the type of fault listed in the table below.

10. Fault codes - Information

    

=  LED off

    

=  LED blinking

LED Coding

FAULT DESCRIPTION

INFORMATION

30 40 50 60 70 80

 

 

 

 

 

1

Locked - overheating.

 

 

 

 

 

3

Locked by ignition fault.

 

 

 

 

 

6

Frost protection.

 

 

 

 

 

7

Input water circulation absent.

 

 

 

 

 

8

Input water circulation fault.

 

 

 

 

 

11

Main exchanger outlet sensor open.

 

 

 

 

 

12

Main exchanger outlet sensor short-circuited.

 

 

 

 

 

13

Main exchanger inlet sensor open.

 

 

 

 

 

14

Main exchanger inlet sensor short-circuited.

 

 

 

 

 

15

External sensor open.

 

 

 

 

 

16

External sensor short-circuited.

 

 

 

 

 

17

Gas overflow fault (TTB).

 

 

 

 

 

18

Disappearance of current flame.

 

 

 

 

 

28

Clima Manager "Module Counter" memory card faulty.

 

 

 

 

 

29

Clima Manager room sensor open.

 

 

 

 

 

30

Clima Manager room sensor short-circuited.

 

 

 

 

 

31

Fault on display board.

 

 

 

 

 

32

Communication problem between main boards and display.

Содержание Mira System CF

Страница 1: ...C COMBINATION BOILER Heating only system Heating sanitary hot water together system plus Open flue System Installation and Operating Manual GB TEMP MODE MAN AUTO THERMOREGULATION C O M PAT I B L E ...

Страница 2: ...18 technical specification 18 19 operating faults 19 Page 1 description 3 2 dimensions 4 3 water specifications 4 4 installation requirements 5 5 fitting the boiler 6 6 electrical connections 7 7 starting up 8 8 fitting the casing 10 9 gas conversion 11 10 fault codes 12 11 points to note 13 Installer s instruction User s instruction Contents ...

Страница 3: ...c vent 9 overheat sensor 10 main heat exchanger inlet thermistor 11 main heat exchanger outlet thermistor 12 electronic control unit 15 ignitor 16 central heating pressure relief valve 19 heating circuit pressure gauge 20 ON OFF push button and ON indicator light 21 sanitary accumulation start button and tank temperature setting button 22 heating function ON and heating temperature adjustment knob...

Страница 4: ...ic height which is the difference in metres between the highest point of the installation and the expansion vessel axis The minimum cold filling pressure of the installation is 0 7 bar recommended pressure between 1 2 and 1 7 bar The pressure of the expansion vessel should always be greater than the static height in metres divided by 10 0 4 3 2 1 5 6 100 200 800 700 600 500 400 300 900 1000 1100 1...

Страница 5: ...ch type of building with public access hospitals shops etc Recommendation if the area is exposed to the risk of lightning isolated ins tallation at the end of an electricity line etc install a light ning conductor Our warranty is subject to this requirement 4 2 BOILER LOCATION install the boiler near a duct for removing the products of combustion never install the boiler above hot plates or ovens ...

Страница 6: ...ish by connecting the chimney use a connecting pipe or elbow specially approved for gas 99 5 pure aluminium or stainless steel connection is provided to fit the pipe or elbow inside the outlet neck of the boiler s draught diverter Cleaning the appliance Once the water has been connected it is essential to clean the installation with an appropriate product dispersing agent to remove filings solder ...

Страница 7: ...ly cable is damaged it should be replaced by the manufacturer the after sales service or a person with a similar status in order to avoid potential danger Room thermostat connection When it leaves the factory the boiler is set to operate without a room thermostat a shunt S is fitted on connector D A room thermostat can be connected to this connector lower the electronic control unit by releasing t...

Страница 8: ...ctronic circuit board behind blanking cover E fig 11 A1 is used to set the Heating Anti cycle Time HAT period to 30 seconds or 3 minutes HAT period during which restarting the burner is prohibited during a heating regulation phase A2 allows the speed of the pump in heating mode to be selected high speed or adaptive speed A3 is used to adjust the heating temperature setting to 40 C irrespective of ...

Страница 9: ...e given for information purposes for a nominal gas distribution pressure to allow any adjustments to the boiler heating output according to the requirements of the appliance They cannot be used to calculate the precise regulated output of the water heater Adaptive speed pump ON OFF ON OFF operation Heating setting to 40 C Modulating Operation Adjustable heating setting 35 to 85 C 30 s anticycle 3 ...

Страница 10: ...the casing offer up the casing fig 14 engage hooks N in notches R operation 1 fit the top of the panel in place screw in the 2 front panel securing screws A Note it is essential to refit both locking bolts A Fig 15 A 8 Fitting the casing 1 N R R N Fig 14 ...

Страница 11: ...ure setting turn nut 3 using an 8 mm open ended spanner fig 17 while holding screw 4 still and adjust the pressure to the value shown in the table nominal output table Adjusting the minimum output disconnect a variable solenoid valve power supply cable fig 18 turn screw 4 using a 5 mm open ended spanner while holding nut 3 fig 18 and adjust the pressure to the value shown in the table minimum outp...

Страница 12: ...t 8 Input water circulation fault 11 Main exchanger outlet sensor open 12 Main exchanger outlet sensor short circuited 13 Main exchanger inlet sensor open 14 Main exchanger inlet sensor short circuited 15 External sensor open 16 External sensor short circuited 17 Gas overflow fault TTB 18 Disappearance of current flame 28 Clima Manager Module Counter memory card faulty 29 Clima Manager room sensor...

Страница 13: ...13 By pass valve assembly direction 11 Particular characteristics ...

Страница 14: ...nt knob 23 heating temperature and operating fault indicator 24 orange burner operating indicator light 25 reset push button reset and red locking indicator light Taps and valves fig 21 31 Central heating flow isolating valve and tank 32 Tank backflow system plus 33 Gas tap 34 Cold water supply tap 35 Central heating return isolating valve 36 Filling tap 16 Heating safety valve Fig 20 Fig 21 12 Co...

Страница 15: ...n the heating circuit according to seasonal requirements Indicator 23 displays the temperature Turn knob 22 towards Max in cold weather towards Min in mild weather Furthermore if your home is fitted with a room thermostat set it to the desired indoor temperature N B Orange indicator light 24 lights up every time the burner ignites Stopping the heating Set knob 22 to the OFF position The boiler the...

Страница 16: ...th the evacuation of combustion products This device puts the boiler in safety shutdown status with indicator lights 22 40 and 80 flashing Automatic restart occurs after an interval of approximately 15 minutes Important if the boiler shuts down repeatedly the exhaust fault must be corrected by getting a specialist to check that the chimney is empty because there is probably a total or partial bloc...

Страница 17: ... the boiler s operating mode to prevent the pump from sticking Precautions to take in freezing conditions We recommend that you contact your gas fitter or After Sales service who will advise you of the measures to take according to your circumstances Domestic hot water circuit system plus The hot water circuit is drained after closing the appliance s water counter and cold water tap open a hot wat...

Страница 18: ...ity 120 150 Specific domestic hot water flow rate ΔT 30 K D 22 2 l mn 24 6 l mn Minimum central heating circuit flow rate 300 I h Maximum heating circuit pressure Pw max 3 bar Adjustable heating flow temperature 35 to 85 C Adjustable domestic hot water temperature system plus 40 to 60 C Electric voltage 230 volt single phase 50 Hz Electrical power consumption 90 W Electrical protection IP X4D Nomi...

Страница 19: ...chapter 8 Room thermostat switched off Set up the room thermostat Red indicator alight Wait for a few minutes Press on reset button 25 fig 20 the red led turn off and the boiler attempts to re light If red indicator alight too frequently please call your localfaîtes service centre Noises in CH system Air presence in CH system or Insufficient pressure Purge of air the system and rise up the system ...

Страница 20: ...420010057900 09 2006 MTS sa Le Carré Pleyel 5 rue Pleyel 93521 SAINT DENIS Cedex Tél 01 55 84 94 94 Fax 01 55 84 96 10 www chaffoteaux maury fr C ...

Отзывы: