3
INSTALLATION INSTRUCTIONS
FOR QUALIFIED GAS INSTALLER
A masonry shelf may be fitted 800mm above the fireplace
but under no
circumstances should any electrical equipment such as a TV be positioned
above. Any ornaments positioned above the fireplace must be able to
withstand the elevated temperatures and moisture. No combustible
materials whatsoever must be used or placed
above the fireplace.
Unpacking
Carefully undo strapping to separate loose parts and remove all plastic
protective sheeting.
Positioning and Sizing
Confirm that the size of Fireplace chosen is the right size for the room. build
up a masonry platform to the customers design, with a suitable hole to drop
the fireplace into, so that it rests on the surrounding rim.
Provide a vent for the primary air to the burner by means of 2x brick-size
holes, leading into the cavity below the unit.
Connect up according to SANS 10087-1
Connect a copper pipe from the gas bottle via a regulator, complying with
SANS 1237, to the Ø8 compression fitting on the control valve, taking into
account the distance from the gas tank, to calculate the size of the copper
pipe.
Setting up
1. Insert the burner with the venturi facing the gas jet, and ensure the burner is
seated correctly.
2. Fill the burner with the special glass pebbles.
Use only the number of glass
pebbles supplied.
Testing and Commissioning
Turn on the gas supply and test for leaks with soapy water.
Ensure that the
WORKING PRESSURE is 2,8 kPa at the control valve
.
See checklist.
Briefing the customer
All instructions must be handed over to the user for safekeeping. Instruct the
customer how to turn the gas on and off and how to light and control the fire.
After commissioning the unit the customer should be instructed on the safe
use of it and the need for regular servicing. Frequency of service depends on
usage, but must be carried out at the first sign of malfunction and at least
once in 2 years.