CH GWH30LB-D3DNA5E Скачать руководство пользователя страница 9

 

1.
2.

          (N·m)

Ф

6

Ф

9.52

Ф

12

15~20

31~35

50~55

Ф

16

60~65

Ф

19

70~75

2.

3.

 

1.

Install indoor unit

NOTE:

When connecting the electric wire if the wire length is not enough, please contact with

the authorized service shop to buy a exclusive electric wire that is long enough and the

joint on the wire are not allowed.

The electric wiring must be correctly connected, wrong connection may cause spare

 parts

malfunction.

Tighten the terminal screw in order to prevent loose.

After tighten the screw, slightly pull the wire and confirm whether is it firm or not.

If the earth wire is wrong connection, that may cause electric shock.

The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that

the dust, moisture may enter in or the connection terminal will be affected by outside force,

and will cause fire or elelctric shock.

Install the indoor unit

The piping can be lead out from right, right rear,

left, left rear.

When routing the piping and wiring from the left

or right side of indoor unit, cut off the tailings

from the chassis in necessary

.

 (show in Fig.2)

(1)Cut off the tailings 1 when routing the wiring only

.

(2)Cut off the tailings 1 and tailings 2 when routing

both the wiring and piping.

(or 1,2,3)

Take out the piping from body case, wrap the piping

electric wire, water pipe with tape and put them th-

rough the piping hole

.

(As show in Fig. 3)

Hang the mounting slots of the indoor unit on the

upper tabs of the rear panel and check if it is firm

enough. (As show in Fig.4)

Install the connection pipe

Align the center of the piping flare with the relevant valve.

Screw in the flare nut by hand and then tighten

 the nut

with spanner and torque wrench refer

 to the following.

Tightening torque table

:

Hex nut diameter

Tightening torque

NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention

to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too

much, otherwise it may cause leakage.

Spanner

Torque wrench

Indoor unit piping

Taper nut     Piping

Fig.4

Fixing hook

Mounting

board

Mounting

board

Right

Left rear

Left

Right rear

Fig.3

Fig.2

Tailing 3

Tailing 2

Tailing1

Gas side piping

External connection

 electric wire

Liquid side

piping

Liquid side 

piping

insulation

Finally wrap it

Water drainage pipe

with tape

Gas side piping 

insulation

Leakage circuit-breaker and air switch of correct capacity must be installed.

5

Содержание GWH30LB-D3DNA5E

Страница 1: ...VICTORIA HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM INSTALLATION MANUAL Models GWH30LB D3DNA5E 230V GWH36LB D3DNA5E 230V...

Страница 2: ...GWH30LB D3DNA5E 230V System Includes GWH30LB D3DNA5E I GWH30LB D3DNA3E O GWH36LB D3DNA5E 230V System Includes GWH36LB D3DNA5E I GWH36LB D3DNA3E O...

Страница 3: ...that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related infor...

Страница 4: ...ct as the standard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been g...

Страница 5: ...the installed location should be 8ft 230cm or more from the floor 6 Select a place about 3 28ft 1m or more away from TVset or any other electric appliances 7 Select a place where the filter can be eas...

Страница 6: ...ly power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire The min distance from the unit and combustive surface is 59in 1...

Страница 7: ...6in 15cm 9 8ft 3m 2 6in 15cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e 7 f t 2 m 12in 30cm Above 8 2ft 2 5m Installation dimension diagram Th...

Страница 8: ...the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should wrap the insulation ma...

Страница 9: ...outing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape an...

Страница 10: ...cuum gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum p...

Страница 11: ...on Install the outdoor drain elbow in 25 hole on the base plate and joint the drain hose to the elbow so that the wastewater formed in the outdoor unit can be drained out to a proper place Chasis Outd...

Страница 12: ...earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient coolin...

Страница 13: ...er it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Ins...

Страница 14: ...tion along with the installation data and dealer contact information will be helpful should your system require maintenance or service www cooperandhunter us PRODUCT INSTALLATION RECORD UNIT INFORMATI...

Страница 15: ...66160000086 Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 MANUFACTURER GREE ELECTRIC APPLIANCES INC OF ZHUHAI www cooperandhunter us...

Отзывы: