Check after installation and test operation

Items to be checked

Possible malfunction

Has it been fixed firmly?

The unit may drop, shake or emit noise.

Have you done the refrigerant leakage test?  It may cause insufficient cooling(heating)

capacity.

Is heat insulation sufficient?

It may cause condensation and dripping.

Is water drainage well?

It may cause condensation and dripping.

Is the voltage in accordance with the rated

voltage marked on the nameplate?

It may cause electric malfunction

or damage the part...

Is the electric wiring and piping

connection installed correctly and securely?

It may cause electric malfunction

or damage the part.

Has the unit been connected to a secure

earth connection?

It may cause electrical leakage.

Is the power cord specified?

It may cause electric malfunction

or damage the part

Is the inlet and outlet been covered?

It may cause insufficient cooling(heating)

capacity.

Has the length of connection pipes

and refrigerant capacity been recorded?

The refrigerant capacity is not accurate.

Test Operation

1. Before test operation

(1) Do not switch on power before installation isfinished completely.

(2) Electric wiring must be connected correctly and securely.

(3) Cut-off valves of the connection pipes should be opened.

(4) All the impurities such as scraps and thrums must be cleared from the unit.

2. Test operation method

(1) Switch on power, press "ON/OFF" button on the wireless remote control to start the 

     operation. 

(2) Press MODE button, to select the COOL, HEAT, FAN to check whether the operation 

is normal or not.

Check after installation

8

Содержание GWH30LB-D3DNA5E

Страница 1: ...VICTORIA HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM INSTALLATION MANUAL Models GWH30LB D3DNA5E 230V GWH36LB D3DNA5E 230V...

Страница 2: ...GWH30LB D3DNA5E 230V System Includes GWH30LB D3DNA5E I GWH30LB D3DNA3E O GWH36LB D3DNA5E 230V System Includes GWH36LB D3DNA5E I GWH36LB D3DNA3E O...

Страница 3: ...that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related infor...

Страница 4: ...ct as the standard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been g...

Страница 5: ...the installed location should be 8ft 230cm or more from the floor 6 Select a place about 3 28ft 1m or more away from TVset or any other electric appliances 7 Select a place where the filter can be eas...

Страница 6: ...ly power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire The min distance from the unit and combustive surface is 59in 1...

Страница 7: ...6in 15cm 9 8ft 3m 2 6in 15cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e 7 f t 2 m 12in 30cm Above 8 2ft 2 5m Installation dimension diagram Th...

Страница 8: ...the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should wrap the insulation ma...

Страница 9: ...outing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape an...

Страница 10: ...cuum gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum p...

Страница 11: ...on Install the outdoor drain elbow in 25 hole on the base plate and joint the drain hose to the elbow so that the wastewater formed in the outdoor unit can be drained out to a proper place Chasis Outd...

Страница 12: ...earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient coolin...

Страница 13: ...er it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Ins...

Страница 14: ...tion along with the installation data and dealer contact information will be helpful should your system require maintenance or service www cooperandhunter us PRODUCT INSTALLATION RECORD UNIT INFORMATI...

Страница 15: ...66160000086 Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 MANUFACTURER GREE ELECTRIC APPLIANCES INC OF ZHUHAI www cooperandhunter us...

Отзывы: