drain is automatically turned on after the controller is turned off for about
15 minutes, but it must be ensured that the main power supply is not
turned off.
1. Plumbing to be performed by a qualified plumber and shall be in
accordance with applicable national and local codes. Steam generator
drains by gravity. A drain line should be lower than the Auto Drain
System assembly . The Auto Drain System valve outlet is 1/2
”
NPT.
Check plumbing code for receptor, trap and vent requirements.
2. Use copper or brass nipple 1/2
”
NPT x 3 , 1
⁄
2
”
or longer (not
supplied) to connect Auto Drain valve. An arrow on the bottom of the
Auto Drain indicates the direction of flow