![CGEO INTERNATIONAL LIMITED CGEO-TEM2 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/cgeo-international-limited/cgeo-tem2/cgeo-tem2_installation-manual_2585430006.webp)
BSIL-T2-1.1 Instruction Manual
CGEO INTERNATIONAL LIMITED
Installation Manual
4
Red
Red
红
Whit
e
白
Gree
n
绿
Blac
Readout
Box
读数仪
Gree
n
绿
Whit
e
白
CGEO-TEM2 thermometer wiring schematic diagram
When measuring, connect the green and white nips of CGEO-PR-VW to the black, red wires
of the transducers to read out directly, or connect green, white nips to black, red wire of
thermometer, and then the thermistor readings can be displayed directly in
C.
Note
,
please do not connect 4 colors nips of readout box to 4 core wires of thermometer
simultaneously, that is, it is just allowed to connect two wires every time to measure
temperature, otherwise it will result in readings error.
There are no polarity difference in signal lines of CGEO-TEM2 thermometer, green,
white wire are changeable.
6.
Temperature Calculation Formula
T
A
B LnR
C LnR
1
273 2
3
(
)
(
)
.
where:
T
Temperature in
C.
R
Resistance of the temperature transducers in
Ω.
LnR
Natural Log of Thermistor Resistance
A
1.4051
10-3 (coefficient is effective in
range
-5
0℃~+150℃)
B
2.369
10-4
C
1.019
10-7
If there is no special readout, the thermistor can be read by using a digital ohmmeter in
conjunction with the above equation, or get the temperature by Appendix A.