BSIL-T2-1.1 Instruction Manual                                                                                                                                         

CGEO INTERNATIONAL LIMITED 

                                                                          Installation Manual 

3.

 

Cable Welding Lengthening

 

A standard CGEO-TEM2 model temperature gauge equips with 1m cable in ex-factory, 

cable model is CGEO-4-SCT. For cable lengthening adopted is CGEO-4-SCT dedicated cable, 

and BSIL-4-SC cable as well as. Proceed lengthening basing on the field circumstance before 

installation. Avoid connection as possible as in the cable buried in soil. If cable connection is 

inevitable,  should  adopt  waterproof  connection,  recommend  using  ES-3  model  dedicated 

heat-shrinkable connector, and also epoxy connector, like 3M ScotchcastTM 82-A1 dedicated 

cable connector, those connector devices can be ordered from Beijing SOIL. 

As following details introduction of connection method of using ES-3 model dedicated 

heat-shrinkable connector.   

Measure the resistance  between cores  of transducer with  millimeter  and note it before 

welding.  Thereinto,  the  resistance  between  green  and  white  core  should  be  3k

  at  room 

temperature 25

. As to CGEO-TEM2 model temperature gauge, the resistance between red 

and black core leads is the same as green and white. 

Before welding divest the outer leather of cable end part, length about 8cm, and expose 

the  core  leads,  roughen  rest  cable  outer  leather  part  with  emery  cloth  or  sandpaper,  length 

about  3  cm.  Sleeve 

φ

12mm  heat-shrinkable  tube  onto  outside  cable  (length  about  14cm). 

Strip outer skin of cores 0.5~0.8 cm with stripping pliers, jacket 

φ

2mm heat-shrinkable tube 

onto  core  leads.  After  twisting  core  leads  together  corresponding  to  colors,  solder  tin  with 

electric  soldering  iron.  Should  avoid  poor  soldering  and  remove  burrs  during  soldering 

process.  5  pieces  of  cores  all  are  needed  to  solder,  please  note:  1).  Stagger  each  core 

connector;  2).  Ensure  every  core  lead  length  same  and  ensure  each  core  uniformly  forced 

when cable is pulled. After soldering, naked core line length about 7 cm, push 

φ

2mm outer 

heat-shrinkable tube onto core leads connector part, and make it shrunk in connector part with 

heat wind gun.    At last    push 

φ

12mm heat-shrinkable tube unto cable connector and heat- 

shrunk  in  connector  part    with  heat  wind  gun. 

φ

12mm  heat-shrinkable  tube  should  be 

pressed 3 cm over each  end of  cable outer skin.  Should  control the temperature when using 

heat-wind gun so that heat-shrinkable tube internal in transparent, fluid status, and fully filled 

with  connector  internal.  But  too  high  temperature  will  melt  core  lead  outer  skin  and  cause 

Содержание CGEO-TEM2

Страница 1: ...CGEO INTERNATIONAL LIMITED CGEO TEM2 Resistance Temperature Sensor Installation Manual REV A ...

Страница 2: ...nts 1 Brief Introduction 1 2 Main Specifications 1 3 Cable Welding Lengthening 2 4 Using Surroundings Installation Notice 3 5 Operation Data Process 3 6 Temperature Calculation Formula 4 7 Trouble Shooting 5 ...

Страница 3: ...transducer Structure of CGEO TEM2 Temperature Gauge The features of CGEO TEM2 Temperature Gauge as follows Good long time stability Stainless steel structure which is adaptable to all kinds of atrocious environment Good water proof capability Long working life High sensitivity Applicable to the measuring of the temperature of liquid solid or gas in the non strong acid non strong alkali or non stro...

Страница 4: ...e Before welding divest the outer leather of cable end part length about 8cm and expose the core leads roughen rest cable outer leather part with emery cloth or sandpaper length about 3 cm Sleeve φ12mm heat shrinkable tube onto outside cable length about 14cm Strip outer skin of cores 0 5 0 8 cm with stripping pliers jacket φ2mm heat shrinkable tube onto core leads After twisting core leads togeth...

Страница 5: ...in strong acid and alkaline areas The CGEO TEM2 Temperature Transducer can be installed directly inside concrete soil or borehole But what is needed to do is to protect the cable and meet all the standard requirements 5 Operation Data Process The signal cable of CGEO TEM2 Temperature Gauge adopts 4 core shielded cable the colors of cable core wires are Black Red Green and White respectively and an...

Страница 6: ...box to 4 core wires of thermometer simultaneously that is it is just allowed to connect two wires every time to measure temperature otherwise it will result in readings error There are no polarity difference in signal lines of CGEO TEM2 thermometer green white wire are changeable 6 Temperature Calculation Formula T A B LnR C LnR 1 273 2 3 where T Temperature in C R Resistance of the temperature tr...

Страница 7: ...s from the norms it is caused normally by cable open or short should focus on inspecting the cable for damage If the cable is damaged or affected with damp the reading will be fuzzy a bit bigger than the correct reading What should be noticed is that if the cable is too long and under the high temperature environment the resistance of cable core should be taken into consideration during calculatin...

Страница 8: ...6 1260 46 311 3 86 99 9 126 64 09K 33 6905 7 1212 47 301 7 87 97 3 127 60 17K 32 6576 8 1167 48 292 4 88 94 9 128 56 51K 31 6265 9 1123 49 283 5 89 92 5 129 53 10K 30 5971 10 1081 50 274 9 90 90 2 130 49 91K 29 5692 11 1040 51 266 6 91 87 9 131 46 94K 28 5427 12 1002 52 258 6 92 85 7 132 44 16K 27 5177 13 965 0 53 250 9 93 83 6 133 41 56K 26 4939 14 929 6 54 243 4 94 81 6 134 39 13K 25 4714 15 895...

Страница 9: ...BSIL T2 1 1 Instruction Manual CGEO INTERNATIONAL LIMITED Installation Manual 7 CGEO TEM2 Semiconductor Thermometer Control Table of Resistance Temperature ...

Отзывы: