SAFETY INSTRUCTIONS

These guidelines are provided for your protection and convenience. Please read them carefully. If you have any ques-

tions regarding the use of your equipment call CFR Technical Service at 800.533.2557. Failure to adhere to instructions 

provided can potentially void any warranties. Precautions and safety warnings are provided for your protection. Failure 

to observe these warnings could result in personal injury and damage to the equipment. When using an electrical appli-

ance, basic safety precautions should always be followed. 

   

WARNING!

Do not attach any device that would engage the trigger in the on position.

   

WARNING!

  To reduce the risk of electric shock, fire, or injury:

1.  This machine should only be used by trained and authorized personnel. Operators must read and understand  

this manual completely and view the training video before operating the equipment.

2.  Do not leave unit unattended when plugged in when not in use. Always unplug the 

equipment from outlet when not in use and before servicing.

3.  Connect to a properly grounded outlet only. (See Grounding Instructions)

4.  Do not use with damaged cord or plug.

5.  Do not handle plug or unit with wet hands.

6.  Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or 

corners. Do not run machine over cord. Keep cord away from heated surfaces.

7.  Turn off all controls before unplugging.

8.  Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.

9.  Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and 

anything that may reduce air flow.

10. Do not use without filters in place.

11. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.

12. Do not expose to rain. Store indoors.

13. If unit is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a local  

CFR service center.

Grounding Instructions 

This unit must be grounded. Grounding provides the 

path of least resistance for electric current, in the event 

of malfunction or breakdown, to reduce the risk of elec-

tric shock. This unit is equipped with a cord having an 

equipment-grounding conductor and grounding plug. 

The plug must be inserted into an appropriate outlet 

that is properly installed and grounded in accordance 

with all local codes and ordinances.

   

WARNING!

  Improper connection of the equipment-grounding conductor can result in a risk of electric 

shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is   properly 

grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet; have a grounded outlet installed 

by a qualified electrician.

Содержание 10416A

Страница 1: ...machine IMPORTANT SAFETY INSTRUCTIONS This manual is to ensure that the CFR Cascade is operated correctly All operators must read understand and practice the following safety instructions Models 1041...

Страница 2: ...and chemicals All operators of the equipment must watch the video and read the manual before using the equipment Please complete and return the enclosed warranty card Parts and Service The Cascade is...

Страница 3: ...ide plates with the two holes in the bracket The side of the plate with the foam should be placed on the inside of the bracket 2 Secure the side plates to the tool head bracket using two black hex scr...

Страница 4: ...ter only runs when the pump is on Trigger Activates solution dispensing WARNING Do not turn power off on the machine by disconnecting the cord The electronic drive control will sense a power failure a...

Страница 5: ...sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces 7 Turn off all controls before unplugging 8 Do not unplug by pulling on cord To unplug grasp the plug not the c...

Страница 6: ...length of the room overlap ping each pass by a minimum of 2 inches If you have an irregularly shaped room Establish a path down the length of the room at the longest point overlapping each pass by a...

Страница 7: ...damage 4 Close the machine fastening the latches 5 Reconnect the vacuum hose and replace the clear tank lid The Cascade utilizes multiple filters in the recycling of cleaning solution It is imperative...

Страница 8: ...hould never be higher than the inlet filter Doing so will activate the automatic vac uum shut off and the machine will not operate CAUTION Water temperature above 140 F 60 C will cause the tank to buc...

Страница 9: ...e the trigger for 30 seconds Adjust p s i from 0 to 400 if necessary Note For P20 OZ models turn on vacuum pump and ozone switches on and let machine run for 15 minutes before use P20 The easy to use...

Страница 10: ...um motor flooding and machine damage 5 When cleaning monitor foam in the solution tank Residue left in the carpeting or upholstery from other cleaning methods may cause excessive foam to collect in th...

Страница 11: ...ll power is off 2 Empty the tank Remove the drain hose from the clamp on the rear of the machine Remove the plug and hold hose over the drain area until tank is empty 3 Remove clear plastic lid 4 Remo...

Страница 12: ...ockage 6 Open and clean the in line strainer filter and replace Disconnect the in line strainer filter by using the quick disconnect coupler Remove any debris from the strainer Keep o ring and threads...

Страница 13: ...a tighter seal 3 Wipe tool with damp cloth and store with head up to prevent clogging of nozzle OPTIONAL ACCESSORIES Wand and Tool Usage Attaching Wand Hand Tool The Cascade self contained cleaning sy...

Страница 14: ...the surface being cleaned to produce maximum cleaning effectiveness and minimum dry times Upholstery 1 Place tool on surface to be cleaned 2 Move pull and push tool at a rate of about one foot per se...

Страница 15: ...s lower check for air leaks in the tank cover gasket and drain hose 4 Check pump performance occasionally against built in pressure gauge Pump running pressure should be 380 400 p s i When pumping flu...

Страница 16: ...aking fittings inline strainer Re prime pump Rebuild pump or pressure regulator if necessary Water dripping from bottom Check machine for excess foaming Add CFR Defoam to tool hose of machine exhaust...

Страница 17: ...PD8 Strain Relief NPT 21 72574A Switch Panel P 20 22 X8282 Bolt 20 x 1 Hex SS 23 X8008N Nut Lock Steel Conduit 24 72434A Jumper Tab 6 25 72432A Terminal Block 7 Positions 26 72361A Panel Motor Control...

Страница 18: ...lon 1 8 x 1 8 43 7AG002 Bushing 1 8 NPT 44 71492A Solenoid 1 8 Orifice 71545A Solenoid 1 8 Orifice 230V 45 7CX002 Nipple Hex MPT 46 7AR013 Nipple NPT x 3 L SS 47 PX6 Female Quick Disonnect 48 72539A B...

Страница 19: ...sher 5 8 SAE Flat Zinc 33 7DT001 Bolt 5 16 18 x 5 8 Hex Tap 34 7CR004 Washer 5 16 USS Flat 35 72551A Caster 4 x 2 Wheel 36 72590A Screw 8 x 5 8 Oval Head 37 72568A Wand Holder 38 7AR013 Nipple NPT x 3...

Страница 20: ...CFR CASCADE 20 Tank Assembly...

Страница 21: ...15 70079C Hose Wire Reinforced 16 7DL008 Hose Clamp 17 71897A Gasket Filter Mount 18 72582A Decal Level Gauge 19 72588A Heat Shrink Tubing 20 SW139 Elbow 1 8 Street 21 7CX001 Nipple Hex 1 8 22 71576A...

Страница 22: ...distributor or autho rized service repair center per the warranty flat rate schedule Service labor will be paid for two years on all warranted polyethylene housings aluminum frames and chassis and one...

Страница 23: ...CFR CASCADE 23...

Страница 24: ...Cascade SERIES P20 INSTRUCTION MANUAl 3101 Wichita Court n Fort Worth TX 76140 n 800 533 2557 n www cfrcorp com Models 10416A P20 SP 10419A P20 10425A P20 OZ SP 10426A P20 OZ 10427A P20 OZ SP 230V 104...

Отзывы: