Guidelines

After your installer does the test burn, the log set
should be operated either with the chimney open or, in
the absence of a chimney, with a window open approxi-
mately 1-2 inches. This operation should last for about
2-3 hours to cure the logs and dissipate any residual
fumes from the new unit.

This unvented gas log heater must not be used with
glass doors closed. If used with glass doors, the
mesh curtain or panels must be closed. The glass
doors must be open to allow combustion air to the
appliance.

When used without glass doors, a fireplace screen or
free standing screen
 must be in place. The screen
must have openings for the introduction of combustion
air.

Always maintain a clear area of at least 3 feet in front of
the fireplace.

Periodically, check the pilot. The flame should be
present if the main supply or safety control valve knob
are not in the “OFF” position.

This unvented gas log set operates as a room heater
when the flue damper is closed. It is equipped with an
Oxygen Depletion Sensor pilot light system that will
automatically shut off the entire unit if the oxygen level
falls below a safe level. Open a window slightly to allow
fresh air into the room when operating the gas log set
as a heater.

NOTE: Unvented gas log owners usually prefer to
operate their sets with the chimney damper closed. This
will put all the heat into the room. However, there may
be times you will desire the full flames of the Hi heat
setting but will find the heat output excessive. You can
open the chimney damper (if you have one) fully or
partially to release some of the heat.

WARNING: Damper handle will be hot if heater has
been operating.

NOTE: Pilot assembly is mounted to the burner
tube support channel.

1. STOP! Read the safety information on Page 8. If a

fabricated firebox with a blower fan is used with this
appliance, turn off electrical power to the fan before
lighting. Turn the manual gas control knob clockwise

 to the full “OFF” position. DO NOT FORCE.

2. Wait 5 minutes to clear out any gas. Then smell for

gas including near the floor. If you smell gas, STOP!
Follow instruction “B” in the safety information on
Page 8. If you do not smell gas, go to the next step.

3. From the “OFF” position, turn the control knob

counterclockwise 

 to “PILOT”.

4. Push in the control knob all the way and hold in.

Immediately light the pilot by depressing the piezo
ignitor button at least once every second until a
flame appears at the pilot assembly. Continue to
hold the control knob in for about 1 minute after the
pilot is lit. Release the knob, and it will pop back up.
The pilot should remain lit. If it goes out, repeat
Steps 1 and 3.

5. Turn the control knob counterclockwise 

 to the

desired setting.

Appliance Lighting Instructions

Match Lighting

1. If the pilot cannot be lighted with the piezo ignitor, it

can be manually lit with a match.

2. Light the match and with the right hand, depress and

turn the control knob to the PILOT” position.

3. With the lighted match, ignite the pilot.

4. Continue to hold the control knob in for an additional

30 seconds to ensure the pilot remains lighted.

Control
Knob

Piezo Ignitor

FP1500

Fig. 7  Control knob.

Содержание UC181L

Страница 1: ...ference Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch an...

Страница 2: ...re in the same room with the heater Do not allow children to touch or operate this gas log heater WARNING Do not use this appliance or any part that has been under water Immediately call a qualified s...

Страница 3: ...imperative that control compartments burners and circulating air passageways of the appliance be kept clean E Your fireplace must include a chain mesh or similar screen The screen must remain fully c...

Страница 4: ...e by 50 cubic feet The result is the maximum BTU Hr the unconfined space can support Example 3 600 cubic feet divided by 50 72 or 72 000 BTU Hr maximum Btu Hr the space can support 3 Add the BTU Hr ra...

Страница 5: ...nput Width Width Depth Height BTU Hr BTU Hr 18 UC181N 29 19 14 17 25 000 39 000 18 UE181N 29 19 14 17 25 000 39 000 24 UC241N Natural 29 23 14 17 25 000 39 000 24 UE241N 29 23 14 17 25 000 39 000 18 U...

Страница 6: ...maximum inlet supply pressure shall be 14 w c The regulator pressure should be 10 w c Pressure Testing The appliance and its individual shut off valve must be disconnected from the gas supply piping...

Страница 7: ...oles in the surround sides of the fireplace and attach the filler panels with 8 x 1 2 self tapping screws supplied with hood assembly Drill 3 32 Dia Hole Left Filler Panel 8 x 1 2 Self tapping Screws...

Страница 8: ...mbly Putting lava rock onto the burner can create carbon monoxide and a hazardous situation Lighting Sequence FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACT...

Страница 9: ...find the heat output excessive You can open the chimney damper if you have one fully or partially to release some of the heat WARNING Damper handle will be hot if heater has been operating NOTE Pilot...

Страница 10: ...ing you may want to use some sort of mounting clip or bracket not provided to reposition the thermostat sensing bulb in the locations listed below FP1501 Fig 8 Thermostat sensing bulb Determining Sens...

Страница 11: ...by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be necessary as you detect dust or carpet...

Страница 12: ...04036 7 Grate 4303064 4303065 8 Aluminum Pilot Connector 3304103 3304103 9 Pilot ODS 7549370 7549370 10 8 32 KEPS Nut 3009016 3009016 11 Orifice 3304010 3304098 12 3 8 MIP x 3 8 Flare Elbow 3304006 33...

Страница 13: ...inal fireplace only One Year Limited Warranty on all other components in original fireplace only Proof of Purchase required If during their lifetime the cement logs fail due to a defect in material or...

Страница 14: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 CFM Home Products...

Отзывы: