Ceyear 87230 Series Скачать руководство пользователя страница 25

Getting Help 

4.1  Fault Diagnosis and Troubleshooting 

 

18

 

 

 

Fig. 3.6 Measurement Window Connected with Multiple USB CW power sensors 

The  87230  series  USB  CW  power  sensor  can  be  connected  with  a  computer  for  microwave  power 
measurement  with  a  virtual  panel  or  user  programming  or  be  connected  with  some  electronic 
measurement instruments of our company for microwave power measurement with its power options. 
For the specific operation, please refer to the User

s Manual of the instrument. 

Measurement instruments supporting the 87230 series USB CW power sensor are as shown in Table 
3.2. 

Table 3.2    Some Instruments which can be Connected with the USB CW power sensor of Our 

Company 

No. 

Instrument Model 

Instrument name 

2442 

Handheld peak power analyzer 

2443A 

Peak power analyzer 

4942B 

Integrated microwave tester 

4957/4958 

Handheld integrated RF tester 

4023/4024 

Handheld microwave spectrum analyzer 

3680A 

Handheld antenna feeder tester 

Note: Please consult technical support personnel for details of conditions whether other instruments are 
supported. 

4  Getting Help 

 

Fault diagnosis and troubleshooting

…………………………………………………………………… .. 18 

 

Error information

…………………………………………………………………………… ..................... 19 

 

Repair methods

…………………………………………………………………………… ....................... 19 

4.1 Fault Diagnosis and Troubleshooting 

 

 

 

Fault Diagnosis and Guides 

This part provides general guidance on how to carry out simple judgment and handling when the 87230 
series  USB  CW  power  sensor  has  any  fault.  If  necessary,  please  feed  back  the  problem  to  the 
manufacturer as accurately as possible, so that we can solve it as soon as possible. 

If the error information is displayed in the indication area of the USB CW power sensor, please check the 
menu 

“[Tool]->[Error]” to know the specific error information description. 

 

Under  normal  conditions,  problems  may  arise  due  to  inappropriate  use  and  setting  or  hardware  or 
software errors. When a problem is encountered, first observe and save the error information, analyze 
the possible causes of the problem and do troubleshooting in advance by referring to the troubleshooting 
steps in this chapter. Alternatively, you can contact our customer service center and provide the collected 
error  information,  and  we  will  help  you  solve  the  problems  as  quickly  as  possible.  For  more  details, 
please refer to the contact information provided in this manual or visit our web site: 

www.ceyear.com

 to 

find the contact information of the technical support center nearest to you. 

This chapter is mainly intended to help users to judge faults of the 87230 series USB CW power sensor, 
and determine whether the after-sales service is needed. It also includes the explanation on the internal 
error information of the instrument. 

NOTE

 

Содержание 87230 Series

Страница 1: ...87230 Series USB CW Power Sensor Quick Start Guide...

Страница 2: ......

Страница 3: ...50MHz 26 5GHz 87233 50MHz 40GHz Options English options English menu and English interface for Export models Version A 1 March 2018 China Electronics Technology Instruments Co Ltd Address No 98 Xiang...

Страница 4: ...ctual situation in the warranty period The specific maintenance matters should be subject to the contract Product Quality Certification This product is certified to fulfill the standards indicated in...

Страница 5: ......

Страница 6: ...fore use 3 2 1 Preparation before Operation 3 2 2 Routine Maintenance 10 3 Typical Applications 12 3 1 Selection of Power Sensor 12 3 2 Virtual Power Measurement Panel 12 3 3 Zeroing and Calibration B...

Страница 7: ......

Страница 8: ...of all functions of the instrument including sensor selection virtual panel introduction zero and calibration before measurement and continuous wave power measurement which is intended to make users u...

Страница 9: ...al describes the basics of remote control programming basics of SCPI SCPIs examples of programming and I O driver library for the purpose of guiding the user to master the SCPIs and methods of the ins...

Страница 10: ...der warranty we will no longer provide the unpaid repairs Please carefully read relevant content of 2 2 Safe Use Guideline of the User s Manual and the following precautions for safe operation In addi...

Страница 11: ...the following steps Step 2 Unpack the instrument and check for any damage to the main unit and attached items Step 3 Verify the items in the packaging box carefully by cross checking with Table 2 1 S...

Страница 12: ...equipment Generally we will use two anti static measures including combination of conductive table mat and wrist combination as well as combination of conductive floor mat and ankle strap If these tw...

Страница 13: ...rogramming software including Microsoft Visual Basics C and LabVIEW 2 USB cable selection The 87230 series USB CW power sensor is equipped with special USB cable which can be screwed and fixed on the...

Страница 14: ...measurement instrument USB host interface and the power sensor green indicator lamp will light up later Step 2 The Equipment Manager of the host can find the new USB Test and Measurement Devices Fig 2...

Страница 15: ...fore measurement and connection to ensure that they are clean and undamaged It is necessary to wear an anti static wrist strap during connection The correct connection methods and procedures are as fo...

Страница 16: ...efore applying a force Gently grasp the end of the torque wrench handle and apply a force in the direction perpendicular to the handle until the breakout torque of the wrench is reached Fig 2 6 Use of...

Страница 17: ...or used an adapter must be adopted for measurement connection In addition even if the measurement port of the analyzer is the same as the type of connector for the port of tested part it is also a goo...

Страница 18: ...and a microwave power signal input port If the connector is damaged or there is dust inside the RF wave band test results will be affected therefore please observe the following methods for maintenan...

Страница 19: ...s wave power measurement As the performance specifications are different by model the user can select the suitable sensor according to the characteristics and measurement requirements of signals to be...

Страница 20: ...evice to be connected in the pop up Instrument Connection window in the system and click Connection button As shown in Fig 3 3 the measurement process is normal Step 2 The user can check the type seri...

Страница 21: ...nd thus calibration is not recommended to the users 3 3 1 Zeroing Zeroing refers to measurement and storage of noise of the whole measurement channel In the process of measurement the zeroed value sha...

Страница 22: ...During measurement of low level signal automatic zero shall be carried out before measurement so as to ensure the measurement accuracy Set the step detection to Off status when the measurement of low...

Страница 23: ...er sensors into the computer or build a multi channel power test system with USB HUB as shown in Fig 3 4 Fig 3 4 Multi channel Power Test with USB HUB The specific operation steps are as follows Step...

Страница 24: ...the currently selected measurement window with yellow border and then select the Equipment drop down menu under the System label to assign the window to other equipment Step 4 Click one measurement w...

Страница 25: ...iagnosis and Guides This part provides general guidance on how to carry out simple judgment and handling when the 87230 series USB CW power sensor has any fault If necessary please feed back the probl...

Страница 26: ...udged clearly Check whether the mechanical connection of the USB cable is correct and whether the electric characteristics are compatible When the problems appears after some settings are made check t...

Страница 27: ...the USB power sensor along with the apparatus in the packaging box 2 Pack the USB CW power sensor with the original packaging material to reduce possible damage 3 Put the linings at four corners of t...

Отзывы: