3.2 Programming Table Summary

Code

Function

Range

Default value

00 #

Exit program mode

n/a

n/a

1 #

COR Source

0 or 1

0  (discriminator)

2 #

External COR polarity

0 or 1

0  (active low)

3 #

Roger beep

0 ~ 2

1  (enabled)

4 #

CTCSS TX (tone 1)

0 ~ 50

0  (disabled)

5 #

CTCSS RX (tone 1)

0 ~ 50

0  (disabled)

6 #

CTCSS TX (tone 2)

0 ~ 50

0  (disabled)

7 #

CTCSS RX (tone 2)

0 ~ 50

0  (disabled)

8 #

CTCSS TX (tone 3)

0 ~ 50

0  (disabled)

9 #

CTCSS RX (tone 3)

0 ~ 50

0  (disabled)

10 #

CTCSS TX (tone 4)

0 ~ 50

0  (disabled)

11 #

CTCSS RX (tone 4)

0 ~ 50

0  (disabled)

12 #

CTCSS tone during hangtime

0 or 1

0  (disabled)

13 #

CTCSS tone 1

0 or 1

0  (disabled)

14 #

Repeater hangtime 

0 ~ 9

2  (2 seconds)

15 #

Interconnect PTT  input

0 or 1

0  (disabled)

16 #

Interconnect PTT input polarity

0 or 1

0  (active low)

17 #

Interconnect mode input

0 or 1

0  (active low)

18 #

Interconnect output polarity

0 or 1

0  (active low)

19 #

Interconnect active period

0 ~ 60

3

(3 seconds)

20 # 

Interconnect repeat

0 ~ 2

1  (enabled)

21 #

Morse code ID send

0 ~ 3

0  (disabled)

22 #

Morse code ID interval timer

0 ~ 90

3  (3 minutes)

23 #

TX time out timer

0 ~ 90

2  (2 minutes)

24 #

TX time out penalty

0 ~ 30

0     (disabled)

25 #

TX disable input

0 or 1

(disabled)

26 #

TX disable input polarity

0 or 1

0  (active low)

27 #

COR Only produces CTCSS

0 ~ 4

(disabled)

28 #

Auxiliary relay code

8 digits max.

(null)

29 #

Morse code ID (call letters)

9 digits max.

(null)

30 #

Over the air programming code

9 digits max.

(null)

99 #

Program factory default

n/a

n/a

Table 4 Programming Summary

Programming Parameters Explained

The following is a list of available programmable features. 

Parameters in bold letters denotes factory defaults

(00# will exit the program mode).

COR Source (1#)     

(Means in which the RM-20 determines receiver activity)

The model RM-20 can be programmed for internal or external COR. Internal COR which is the factory default 
requires that the RX Audio input be connected to the discriminator of the receiver. (See RX Audio description)

Otherwise, the External COR input must be used and this item programmed to “External COR” To program this 
item enter the command code followed by a 1 or 0, (don’t forget to enter a # (pound ) key between commands and at 
the end of the entry sequence).

1#0# = internal

1#1# = external

Содержание M-20 Repeater Maker plus

Страница 1: ...20 Repeater Maker plus CES Wireless Technologies Corp 925 122 South Semoran Blvd Winter Park FL 32792 407 679 9440 support ceswireless com www ceswireless com MAN79 Version 1 2 Updated 31 Jan 10 Print...

Страница 2: ...INSTALLATION 7 2 5 COMPONENT LAYOUT 8 2 6 RADIO INTERFACE CONNECTION 8 2 7 INTERCONNECT INTERFACE PINOUT 9 2 8 PROGRAMMING INTERFACE CONNECTOR PINOUT 9 2 9 JUMPERS 9 2 10 RADIO AND AUXILIARY RELAY IN...

Страница 3: ...Installation and programming of this CES product must be completed by a qualified two way radio technician or engineer Equipment for repair may be returned to the factory freight prepaid only with pri...

Страница 4: ...e are engaged in a program of continual product development the specifications and descriptions outlined in this manual are subject to change Please consult the amendment section for changes When you...

Страница 5: ...t 0 5 lb Cabinet Aluminum Extrusion Voltage 12 V DC Current Idle 30 7mA Transmit 90 00mA Interface Cable 6 ft shielded 9 conductor cable and RM 20 connectors provided Potentiometers for level adjustme...

Страница 6: ...er plus includes Programmable Roger Beep Programmable disconnect time out timer with disconnect warning beeps Programmable hang time Auxiliary relay controlled with programmable DTMF string PTT relay...

Страница 7: ...or or deviation meter optional for transmitter deviation 1 8 flat blade adjustment tool or jeweler s screwdriver Oscilloscope or RMS meter voltmeter A DTMF telephone Handset Digital Multimeter Portabl...

Страница 8: ...ally closed 3 AUX COMMON Auxiliary relay common 4 TX DISABLE Input 35 to 35 volts switch 2 5v 47k pull up to 12v 5 TX CTCSS Output CTCSS Output to Transmitter 6 TX AUDIO Output Transmit Repeat audio t...

Страница 9: ...nect 12 volts not reverse protected Table 2 Interconnect interface DB 9 female connector 2 8 Programming Interface Connector Pinout Pin Function Signal Description 1 N A 2 Tip 3 Ring 4 N A Table 3 Pro...

Страница 10: ...n 2 PTT NC This connection is generally not used In applications where two RM 20 s are used for cross band applications this contact may be used See Figure 3 0 Pin 3 Aux Common optional Pin 4 TX Disab...

Страница 11: ...olt or lower to 3 volts or higher The active state of this input is programmable Pin 14 Ground same as pin 8 Pin 15 12V DC Connect to a source of regulated filtered 12VDC supply If separate power supp...

Страница 12: ...the transmitter frequency If this level is difficult to obtain install or remove JP5 as follows If deviation is above 4 KHz and R69 is at minimum remove JP2 factory default If deviation is below 4 KHz...

Страница 13: ...ase it as soon as the tone is heard Over the Air programming The model RM 20 can also be programmed over the air using a DTMF microphone or a portable radio equipped with DTMF keypad However an over t...

Страница 14: ...code ID interval timer 0 90 3 3 minutes 23 TX time out timer 0 90 2 2 minutes 24 TX time out penalty 0 30 0 disabled 25 TX disable input 0 or 1 0 disabled 26 TX disable input polarity 0 or 1 0 active...

Страница 15: ...nly Refer to tone chart in this manual for tone number and frequency CTCSS during hangtime 12 When this code is enabled the RM 20 will generate a CTCSS tone for the duration of the hangtime A CTCSS TX...

Страница 16: ...econds don t forget to enter a pound key between commands and the end of the entry sequence 19 3 3 seconds 19 0 through 90 0 through 90 seconds Interconnect repeat 20 This parameter determines what au...

Страница 17: ...s code is programmable for no penalty or up to 30 seconds at 1 second interval 24 0 no penalty 24 1 through 30 1 through 30 seconds TX disable in 25 This code is normally used when two RM 20 s are use...

Страница 18: ...S RX tone1 code 5 Morse code ID letters 29 A Morse code ID can be sent based on a timer when COR CTCSS are deactivated or both When programming the ID call letters each character is entered by pressin...

Страница 19: ...103 5 14 199 5 40 107 2 15 203 5 41 110 9 16 206 5 42 114 8 17 210 7 43 118 8 18 218 1 44 123 0 19 225 7 45 127 3 20 229 1 46 131 8 21 233 6 47 136 5 22 241 8 48 141 3 23 250 3 49 146 2 24 254 1 50 15...

Страница 20: ...during Hang time 13 CTCSS tone 1 14 Repeater Hang time 15 Interconnect PTT input 16 Interconnect PTT input polarity 17 Interconnect mode input 18 Interconnect output polarity 19 Interconnect active pe...

Страница 21: ...CES SUPPORT 407 679 9440 Page 21 MAN79 CES 2009 5 0 Circuit Diagram...

Страница 22: ...CES SUPPORT 407 679 9440 Page 22 MAN79 CES 2009 6 0 Amendments Manual revised 01 31 10 5 26 PM...

Отзывы: