2019 Cervis, Inc.
13
7. When you have found the receiver you want to control, press the green
HORN/START
pushbutton again to pull in the MLC relays.
Note:
Once you have selected a receiver and energized the MLC relays, the CB-xW
transmitter and receiver are linked (associated), and you can run the attached
machinery.
Notes:
If you purchase a spare transmitter after the original system ships, you will need to
associate it yourself before it will work with that system.
Each transmitter must to be associated one time. Once associated with a receiver, that
transmitter will work with that receiver until the receiver ID is cleared (see Section 2.8).
The transmitter will work in a first-come/first-serve fashion, where only one transmitter
can ever be linked to a receiver unit at a time.
2.7.1 Virtual Receiver Unlock
When the receiver
’s Association functionality is disabled (DIP Switch 8 is
DOWN/OFF
), you
cannot link any transmitters to that receiver. To completely enable association again, you must
access the receiver mounted to the machinery and physically flip DIP Switch 8 to the
UP/ON
position (see receiver manual).
However, if you cannot immediately reset the receiver
’s Association DIP Switch physically—but
still need remote machinery control enabled
—the transmitter can create a temporary
virtual
association.
To Virtually Unlock Your Receiver:
Note: First, make sure that at least one transmitter was previously associated with the target
receiver.
1. With the transmitter
OFF
, turn the keyswitch to the ON position.