3.0 Dissociate Handheld from Base Unit
In some circumstances it may become necessary to break the communication link, or dissociate
a handheld and a base unit. The Dissociate procedure is almost identical to the Associate
procedure, except the Dissociate button is used and held throughout the process instead of the
Associate button.
Using the following steps will break all previously established handheld remote
links. It will be necessary to perform the Associate Procedure (2.0 above) using
each handheld to re-establish communication links with a base unit.
1. Remove power from the base unit and turn off (PTO – time out) the hand-held
device.
2. Stand near the base unit in unobstructed, clear line-of-sight with the handheld in
hand.
3. Simultaneously press and hold the Associate (B1) and Dissociate (B2) buttons.
RX and ER light.
4. Continue to hold both buttons until TX and RX light steady.
5. When TX and RX light, release B1 and B2. ER and BA light.
Note: If the next button press is not immediately performed (approximately 1sec.), all LEDs
flash and the Associate procedure is aborted. The process must be started anew to establish
the communication link.
6. Immediately press and hold the Dissociate button (B2).
7. TX begins to slowly blink. Continue to hold B2.
8. Apply power to the base unit.
All established links with the base unit are removed. The SmaRT base unit will not communicate
with any handheld remote units. A handheld remote must use the Associate Procedure (2.0) to