SmaRT x18 Handheld Battery Installation 

The handheld remote operates between 1.6 to 3.2 VDC powered by four factory installed 1.5 V 
“AA” cell batteries. Cervis, Inc. recommends having fresh spare batteries on hand at all times 
that the system is in use. 

Note: The battery cover is designed so that the four screws holding the battery cover in 

place are 

“captive” to the cover. Although not easily removed from the cover itself, be aware 

that if the screws are over-loosened while opening the battery compartment, they can be 
completely removed, increasing the risk of loss. All four screws must be installed to maintain 
a tight seal. 

1.  Place the remote face down, and remove the four screws holding the battery 

cover in place. Remove the battery cover. 

2.  Remove the discharged batteries and properly dispose according to local 

regulations. 

3.  Plug each fresh battery into a terminal cradle observing proper polarity. The 

interior of the cradle shows polarity markings for each terminal (Figure 3). Make 
sure the batteries are firmly seated in the cradle. 

4.  Replace the battery cover. Secure the cover with the four screws. Make sure 

they are tightened enough to compress the seal, but be careful not to over-
tighten. 

 

Figure 3. OO-218 Handheld Battery Compartment 

 

 

Observe proper polarity when placing batteries into the cradle. 
Improper battery placement can cause excessive heat, battery 
explosion, injury to the operator, and damage to the remote. 

Note: Cervis, Inc. recommends removing the batteries from the handheld remote when it is 

going to be stored for any extended length of time. 

Содержание SmaRT 218

Страница 1: ...2020 Cervis Inc SmaRT 918 218 Remote Control System User Manual U053 5 1 SmaRT_OO x18_Sys...

Страница 2: ...rit 6 disponible sur le site Web de Sant Canada https www canada ca en health canada services environmental workplace health reports publications radiation safety code 6 health canada radiofrequency e...

Страница 3: ...urve 14 8 0 Base Unit Troubleshooting 15 List of Figures Figure 1 Standard SmaRT x18 System 3 Figure 2 SmaRT x18 18 Button Handheld Remote Control Unit 4 Figure 3 OO 218 Handheld Battery Compartment 5...

Страница 4: ...itioned or when the button is released Or in some cases when the button is pressed again SmaRT Base Unit Input output I O unit that the controlled machine is connected to SmaRT base units communicate...

Страница 5: ...e and remove power from the base unit before attempting any maintenance This will prevent accidental operation of the controlled machinery Remove power from the base unit by detaching the 12 pin cable...

Страница 6: ...uct should be recycled according to local regulations Contact local authorities for detailed information This product may be returnable to the distributor for recycling Contact your distributor for de...

Страница 7: ...unit A SmaRT system can communicate in congested radio environments using Direct Sequence Spread Spectrum DSSS wireless technology at a system dependent 900 MHz or 2 4 GHz range The system communicati...

Страница 8: ...base unit in congested radio environments The handheld remote allows seamless association to a SmaRT base unit without the need to open either unit s case The rugged weatherproof handheld enclosure al...

Страница 9: ...emove the four screws holding the battery cover in place Remove the battery cover 2 Remove the discharged batteries and properly dispose according to local regulations 3 Plug each fresh battery into a...

Страница 10: ...e typically mapped to specific base unit outputs inputs M1 through M16 as shown below Figure 4 Handheld Buttons Table 1 Handheld Button to BU I O Mapping Button BU Map M I O Channel BU Connector P and...

Страница 11: ...Red light solid 4 Continue to hold both buttons until LED 2 Amber goes out Immediately release both buttons and press Button 1 the button between the ON and OFF buttons 5 Continue holding Button 1 Ap...

Страница 12: ...Two connecting cable models are available for base unit P1 and P2 SmaRT base units feature seamless association to a SmaRT handheld unit without the need to open the case Using Direct Sequence Spread...

Страница 13: ...ses use the configuration diagrams Cervis Inc supplied as a guide Figure 7 illustrates dimensions for drilling mounting holes Figure 8 illustrates the wiring harness connections Figure 7 Internal and...

Страница 14: ...tton 3 10 M2 button 2 9 M1 button 1 3 M7 button 7 7 VDC 2 M6 button 6 7 M13 button 13 6 M12 button 12 5 M11 button 11 4 M10 button 10 3 M9 button 9 2 UNUSED 1 VDC NOTE VDC Battery Power Supply Positiv...

Страница 15: ...em 2020 Cervis Inc 11 Figure 9 Field Wiring Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Fi...

Страница 16: ...GHz RF Power 2 mW License License free Modulation DSSS Antenna Internal Enclosure Dimensions 9 x 3 x 1 231 8 mm x 79 4 mm x 31 8mm Total Weight 15 2 oz 430 9 gr Durability High impact polymer case Pol...

Страница 17: ...cceleration 10 0 g peak shock acceleration INDICATORS 5 In Green Input On Out Green Output On Health Green Pulse sec OK TX RX Green Receive Red Transmit Power Amber OK Red Green Fault ENCLOSURE Dimens...

Страница 18: ...SmaRT 218 918 U053 5 1 SmaRT_OO x18_Sys 14 7 0 BU x16F Output Current Derating Curve Figure 10 Base Unit Output Current Derating Curve...

Страница 19: ...mal condition Out LED pulsing Amber Indicates an over current condition Out LED slowly pulsing Amber Over temperature indication In LED not active Check to make sure that voltage to channel is less th...

Страница 20: ...t www cervisinc com The Cervis Inc and SmaRT Wireless logos are trademarks of Cervis Inc Contact via Phone 724 741 9000 2020 Cervis Inc All rights reserved Content is subject to change without notice...

Отзывы: