background image

 

 

SmaRT 206 

 

 

U024.2-SmaRT_206_SYS-R 

10 

5.0  System Operation 

The PTO-206 Handheld Remote buttons are 

push-to-operate

 only. Each button is 

dedicated to its assigned, hardwired BU-206F output driven by the base unit. The 
output is only controlled when the appropriate button is pressed and held. Once the 
button is released, the BU-206F output under control stops, and the BU-206F waits for 
the next command sent by the PTO-206. The following instructions outline what is 
needed for use of and how to use the SmaRT 206 Remote Control System. 

5.1  Initial Use Instructions 

Note: You must be line of sight and within 300 ft. (100m) of the base unit while 

holding the handheld. 

Note: Each BU-206F can establish communication links with as many as eight (8) 

different PTO remote units. Association for each PTO remote used must be 
individually established. 

CAUTION 

 

Be aware that using the Disassociation Procedure (Heading 1.4.2) will 
break all previously established handheld remote links. Once PTO remote 

↔base unit links are broken, it will b

e necessary to perform the 

Association Procedure (Heading 1.4.1) using each handheld to re-
establish communication links with the base unit before the 206 Remote 
Control System can be used. 

 

1.  Verify the HN-1001 harness connections with the controlled devices are 

correct and that the wiring harness is firmly plugged into the BU-206F 
base unit. 

2.  Communication between the remote handheld and base unit must be 

established (Heading 1.4.1). Remove power from the BU-206F. 

3.  Stand near the base unit with the remote in hand. 

4.  Press and hold both Button 1 and Button 2, the top two buttons (the 

Association and Disassociation buttons). The TX LED glows steady 
green. Continue to hold both buttons until the LINK LED begins to flash 
amber. 

5.  Release the two buttons. The RX LED flashes red for about two seconds. 

You must perform the next step within this two second period or the 
Association process is aborted. 

6.  Press and hold the Association button—Button 1. The RX LED goes out, 

the TX LED glows steady green, and the LINK LED glows steady amber. 

7.  Apply power to the base unit while continuing to hold Button 1 

(Association). The BU-206F and PTO-206 exchange information 
establishing the communication link. Upon process completion, the amber 
LINK LED goes out, the red RX LED begins flashing, and the TX LED 
glows steady green.  

Содержание SmaRT 206

Страница 1: ...2008 Cervis Inc 206 Remote Control System User Manual DN U024 2 SmaRT_206_SYS R...

Страница 2: ...ce pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi...

Страница 3: ...stallation 7 4 0 Using the SmaRT PTO 206 Handheld Remote 9 5 0 System Operation 10 5 1 Initial Use Instructions 10 6 0 Specifications 12 6 1 PTO 206 Handheld Remote 12 6 2 BU 206F Base Unit 13 List of...

Страница 4: ...ority to operate the equipment Make sure that the machinery and surrounding area is clear before operating Do not activate the remote control system until certain that it is safe to do so Turn off the...

Страница 5: ...t tight 5 water jetted from any direction on the enclosure shall have no harmful effects PTO Push to Operate Command broadcast only while a button is depressed The command ends when the button is rele...

Страница 6: ...SmaRT 206 U024 2 SmaRT_206_SYS R iv This page is intentionally left blank...

Страница 7: ...that require remote operation Figure 1 PTO 206 Handheld Remote and BU 206F Base Unit 1 1 Features Rugged compact weatherproof high impact polymer IP65 enclosures Operating Temp 20 C to 55 C Storage Te...

Страница 8: ...handheld enclosure is constructed of rugged high impact polymer and a polycarbonate face plate securely sealed and attached by eight screws that is then overlaid with a durable attractively printed p...

Страница 9: ...to a SmaRT handheld unit without the need to open either the remote or base unit case All controlled apparatus connections to the base unit are made using a single cable The base unit compact enclosur...

Страница 10: ...held in your hand 3 Simultaneously press and hold the Association and Disassociation buttons see Figure 5 The TX LED glows steady green Figure 5 Handheld PTO Front Panel 4 Continue to hold both button...

Страница 11: ...all previously established handheld remote links It will be necessary to perform the Association Procedure 1 4 1 above using each handheld to re establish communication links with the base unit 1 Rem...

Страница 12: ...partment cover and lift the cover from the handheld 2 If installing batteries in an empty battery compartment install three fresh size AAA batteries Be sure to position the batteries as shown in Figur...

Страница 13: ...t is left much to your discretion with the following guidelines Make sure that the configuration diagrams supplied with the system are available Keep them where they can be easily accessed when needed...

Страница 14: ...y marked on the insulator of each wire Figure 8 Wiring Harness Cable Figure 9 Field Wiring Layout CAUTION Be sure the ends of all unused wires are insulated when making your connections to protect aga...

Страница 15: ...e SmaRT PTO 206 Handheld Remote has six 6 push to operate buttons and three 3 diagnostic LEDs PTO buttons 1 and 2 have dual functions as described in Figure 11 Figure 11 PTO 206 Front Panel Output 2 A...

Страница 16: ...ure Heading 1 4 1 using each handheld to re establish communication links with the base unit before the 206 Remote Control System can be used 1 Verify the HN 1001 harness connections with the controll...

Страница 17: ...ates the output to which it is assigned When a PTO button is pressed its assigned base unit output is active and the base unit Out LED should glow green for as long as the output is active When the PT...

Страница 18: ...55 C 40 F to 131 F Humidity 0 to 100 Radio Frequency 2405 2480MHz RF Signal 2mW License License free Modulation DSSS Antenna Internal Enclosure Dimensions mm 136 38 x 67 96 x 28 42 inches 5 37 x 2 68...

Страница 19: ...Shock IEC60068 2 6 10Hz to 150Hz 1 0g peak acceleration 10 0g peak shock acceleration Radio Frequency 2405 2480MHz RF Signal 2mW License No license required Modulation DSSS Antenna Internal Enclosure...

Страница 20: ...SmaRT 206 U024 2 SmaRT_206_SYS R 14 Cervis Inc Visit our Web site at www cervisinc com and are trademarks of CERVIS Inc 2008 Cervis Inc All rights reserved Content is subject to change without notice...

Страница 21: ...Remote Control System 2008 Cervis Inc 15...