TECHNICAL MANUAL. START-UP AND OPERATION
How to set the temperature?
Press the key “set” for at least 2 seconds, then enter the state of temperature setting, here the LED displays the setting tempera-
ture, then using “
5
” key or “
6
” key can change the parameter (the key “
5
” adds 0.1°C, the key “
6
” minuses 0.1°C,
press and
hold it over 0.5 seconds can add or minus rapidly). After setting, press “set” again, then exit the state of parameter
setting. (The
setting temp range is limited by the parameters F13 and F14; please refer to the senior operation). Pressing the key
“M” in the setting process means cancel and exit, but the setting value will not be saved.
How to read the temperature of the evaporator sensor?
When displaying current temperature, press “
6
” key, Controller will display defrosting temperature. Loose “
6
” key, then return to
current temperature.
Advanced Operation
Press the key “M” and hold it for
5
seconds, and if you have set the password, the LED display the “PAS” to hint you to enter the
password, you can use the key “
5
” and “
6
” to enter the password, if the password is correct, the LED will display the
parameter
code, use “
5
” or “
6
” to select the parameter code. Pressing the “set” key can make it to show the value of the
parameter after
select the parameter, here you use “
5
” or “
6
” to set the parameter (pressing the key and not release can add
or minus rapidly),
then press the “set” key to return to the state of showing parameter code after finishing setting. Pressing the key
“M” can exit the
parameter setting state when display the parameter code, pressing the key “M” means cancel when in the process of
setting parameter, and the parameter will not be changed.
Internal parameter code is showing bellow:
Sort
Code
Parameter Name
Range
Factory setting
Unit
Remark
F11 Setting temperature
F14 – F13
28
℃
/
℉
The setting range is limited
by F13 and F14
F12 Temperature difference
0.1 – 20
1.0
℃
/
℉
Control the temperature
difference, please refer to the
temperature controlling
F13 Max setting temperature
-58 - 302
35
℃
/
℉
F14 Min setting temperature
-58 – 302
10
℃
/
℉
Notice: the controller will
follow the rule of
F14<F11<F13 forcibly, if
you find out that one
parameter can not be
adjusted, it is because the
parameter is limited by other
parameters, you must first
adjust other parameters
F17
Auto mode temperature
difference
3 - 20
3
℃
/
℉
If F17<F12,F17=F12
admited
F18
Evaporator sensor
adjustment
-20 – 20
0.0
℃
/
℉
Adjust the outdoor machine
sensor bias
Temperature
F19 Temp sensor adjustment
-20 – 20
0.0
℃
/
℉
Adjust the temperature
sensor bias
F21 Compressor delay time
0 -- 10
3
min
Compressor
F29
Compressor controlling
COOL / HEAT
HEAT
-
COOL: refrigeration mode
Содержание HPP040
Страница 2: ......
Страница 11: ...BLP BLY HEAT PUMP english ATTENTION ...
Страница 30: ...BOMBA DE CALOR BLP BLY español ATENCIÓN 29 ...
Страница 49: ...47 POMPE Á CHALEUR BLP BLY français ATTENTION ...
Страница 68: ...deutsch ACHTUNG 65 ...
Страница 87: ...POMPA DI CALORE BLP BLY italiano ATTENZIONE 83 ...
Страница 106: ...BLP BLY WARMTEPOMP nederlands OPGELET 101 ...
Страница 125: ...BOMBA DE CALOR BLP BLY portugués ATENÇÁO 119 ...