Important Safety Warnings 

 
 
This manual contains instructions and warnings that should be followed during the 
installation, operating and storage of the UPS system. Please keep this manual for 
further reference. 
 

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity 
controlled indoor area free of conductive contaminants. (See the specifications for the 
acceptable temperature and humidity range) 
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and 
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances 
such as radiators. 
CAUTION! Do not plug the UPS input into its own output. 
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages 
or any other liquid-containing vessels on or near the unit.   
CAUTION! In the event of an emergency, press the OFF button and disconnect the power 
cord from the AC power supply to completely disable the UPS. 
CAUTION! The UPS installation must be correctly ground in order to reduce leakage current 
below 3.5mA. 
Attention The UPS output is supplied by two sources. When the UPS is disconnected from 
mains power, hazardous voltage may still be present from the internal battery. The battery 
should be disconnected when maintenance or service work inside the UPS is necessary. 
CAUTION! Servicing of batteries should be performed or supervised by 

qualified 

personnel 

only.   
CAUTION! When replacing the batteries, use the same number and type of batteries. 
CAUTION! Dispose of batteries in the correct manner and in line with local laws and 
regulations. Never dispose of batteries in a fire. Do not attempt open the battery. Released 
electrolyte is harmful to the skin and eyes. 
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 
CAUTION! A battery can present a risk of electric shock and short circuit.   

CAUTION! This is a category C2 UPS product. In a residential environment, this product may 
cause radio interference, in which case the user many be required to take additional measures. 

 
 

Designed and Engineered by: 
 
Power Control Ltd 

www.certaups.com

   

 

 

 

 

 

 

Specifications 

MODEL 

C60-800 

C60-1000 

C60-1500 

C60-2000 

CAPACITY 

800VA/480W 

1000VA/600W 

1500VA/900W 

2000VA/1200W 

INPUT 
Input Voltage 

220/230/240VAC 

Voltage Range 

162-290VAC 

OUTPUT 
Voltage Regulation 

+/-10% 

Transfer Time 

Typical 2-6ms, 10ms max. 

Waveform 

Simulated Sinewave 

BATTERY 
Type & Number 

12V/9Ah x 1 

12V/7Ah x 2 

12V/9Ah x 2 

12V/9Ah x 2 

Charging Time 

4-6 hours recover to 90% capacity 

PHYSICAL 
Dimension 
(WxDxH) mm 

100 x 287 x 142 

146 x 350 x 160 

146 x

 397 x 205 

Net Weight (KG) 

4.9 

8.0 

11.1 

11.5 

 

 