Table 2.  iModem Family Pin Description. 

PIN NAME  I/O 

FUNCTION 

 

 

RING 

 

I/O 

Directly connects to the telephone line’s Ring lead through a user supplied RJ-11C jack. 

 

 

TIP 

 

I/O 

Directly connects to the telephone line’s TIP lead through a user supplied RJ-11C jack. 

 

 

NC 

 

--- 

NO CONECTION 

 

 

NC 

 

--- 

NO CONECTION 

 

 

SPK 

 

SPEAKER.  Audio output for speaker.  See speaker control diagram. 

 

 

SEND 

 

SEND EMAIL.  Not Currently Supported.  No Connect. 

 

 

IN 1 

 

Input.  Not Currently Supported.  No Connect. 

 

 

SENT 

 

EMAIL SENT.  Not Currently Supported.  No Connect. 

 

 

IN 2 

 

Input.  Not Currently Supported.  No Connect. 

 

10 

 

TXD 

 

TRANSMIT DATA.  Serial transmit data input.  Marking, or a binary 1 condition is indicated 
by a HIGH. 

 

11 

 

RXD 

 

RECEIVE DATA.  Serial Receive data output.  Received marking or a binary 1 condition is 
indicated by a HIGH. 

 

12 

 

NC 

 

--- 

NO CONECTION 

 

13 

 

DTR 

 

DATA TERMINAL READY INPUT.  Active LOW.  Switching off DTR can either return 
modem to command state, disconnect phone call, or reset modem.  DTR should be set 
LOW when not in use. 

 

14 

 

DSR 

 

DATA SET READY.  LOW indicates handshaking with a remote modem in progress, 
and/or the data carrier of a remote modem has been detected. 

 

15 

 

RI 

 

RING INDICATION.  This signal follows the frequency of the ringing signal and is normally 
about 20 to 40 Hz for 2 seconds on with 4 second off. 

 

16 

 

CTS 

 

CLEAR-TO-SEND.  Output always LOW.  Reserved for flow controls with FAX option.  Not 
active, let float. 

 

17 

 

DCD 

 

DATA CARRIER DETECT.  LOW indicates a data carrier from a remote modem has been 
detected.  Must enable with 

AT&C1

 Hayes command. 

 

18 

 

NC 

 

--- 

NO CONECTION 

 

19 

 

VCC 

 

--- 

DC SUPPLY.  5V ± 5% required. 

 

20 

 

GND 

 

--- 

GROUND.  Note: Noise should be less than 25mV peak to peak. 

 

21 

 

RST 

 

RESET.  Active HIGH.  This input must be asserted HIGH for at least 10ms to reset the 
modem.  RESET is then returned to LOW for normal operation.  If no system reset is 
available, let this pin float to enable internal reset. 

 

22 

 

RTS 

 

REQUEST TO SEND.  Active Low.  Used for flow control.  Should be tied Low when using 
SEND pin and when using 

@T

 commands for CH2160 only.  DO NOT CONNECT for 

CH2124. 

 

Содержание CH2165

Страница 1: ...products are designed to exploit the internet to facilitate the utilization of machine to machine interactions Using email information can easily be transferred between systems and can be transmitted...

Страница 2: ...e data stream with a CR CR Alternatively messages of finite length can pre stored locally on the CH2165 in RAM memory and then sent when needed The data stream termination sequence for pre stored mess...

Страница 3: ...the issuance by the host processor to the iModem the appropriate T command to send retrieve delete email PSTN dial up logon authentication and email transmission retrieval and or deletion are perform...

Страница 4: ...evels of internet and email status information Using the TCS PPP command the user can monitor all the internet PPP communication Additionally the user can determine internet connectivity status by iss...

Страница 5: ...THE FACTORY all T command communication between the CH2165 iModem and the host processor is conducted over the serial interface at 19 2kbps CH21XX DTE Speed AS DELIVERED FROM THE FACTORY the CH2165 i...

Страница 6: ...ed Password T PI n T PI Set ISP Login password n T PM n T PM Set POP3 email retrieve password n Username T UI n T UI Set ISP Login username n T UM n T UM Set POP3 email retrieve username n POP3 Retrie...

Страница 7: ...ver This address becomes the DESTINATION address of the Error Email and appears in the TCP IP header T AF n T A Set email FROM address n This is the address that follows the FROM located in the body o...

Страница 8: ...ED V Display verbose command syntax Z Display factory default parameter restore command syntax Server Addresses T SS n T S Set SMTP server symbolic name n This symbolic name is used by the CH2165 to d...

Страница 9: ...ircuit PCB 5 No additional circuitry other than that shown in Figure 3 may be connected between the iModem module and the RJ 11C jack Doing so will invalidate the conveyed FCC approval 6 The iModem th...

Страница 10: ...tions will be provided by the FCC within 30 days of their request for the same Telephone Company Procedure The goal of the telephone company is to provide the best service it can In order to do this i...

Страница 11: ...INPUT Active LOW Switching off DTR can either return modem to command state disconnect phone call or reset modem DTR should be set LOW when not in use 14 DSR O DATA SET READY LOW indicates handshakin...

Страница 12: ...lab to verify compliance For Canada use either 10 resistors carbon film or SMD parts 1 8 watt minimum as described in paragraph B above 2 Over Voltage and Lightning Protection A Surge Protection is p...

Страница 13: ...iModem Electrical Specifications Symbol Characteristic Min Typ Max Units VCC Positive Supply Voltage 4 5 5 0 5 5 V ICC Off Hook Nominal Operating Current VCC 5 5V when modem is Off Hook 300 0 mA VIH...

Страница 14: ...0 mA Return Loss 1000 Hz 15 dB 600 Ohm Ring Frequencies 18 20 30 Hz Receiver Insertion Gain 0 5 0 0 0 5 dB Transmit Power 9 5 dBm 600 Ohm Data Mode First Character After Reset See Note 1 25 0 sec Dela...

Страница 15: ...ts or other rights of third parties resulting from its use No license is granted under any patents or patent rights of Cermetek Cermetek provides the user with a FCC USA and IC Canada Approved or Appr...

Отзывы: