TND531-E0

 

 

Page 6 of 9

 

www.cermate.com

 

Sample:

 

the object ID is ”9999” and this ID is the node address of the    PM software 

setting. 

 

 
 
 
 
 
 
 
 
 
 
 
 

Note: The node address of the PM Designer software (Before Ver1.2.57) is 

0~32767. Please setting the object ID to 0~32767. 

Device AV1=456.000 (Floating Point) 

 

 

Содержание TN531D

Страница 1: ...Technical Document Version 0 0 January 2010 www cermate com PLC Connection Guide TN531D BACNet IP Driver Setting Revision Record Revision Date Content Owner ...

Страница 2: ...ce This tech note introduces how to connect BACNet IP device with the PanelMaster HMI When you wish to link with the BACNet IP device please follow below steps to use the CAS BACNet Explorer to search on line device 1 CAS BACNet Explorer setting ...

Страница 3: ...e several times you can use same e mail account to apply it Step 3 Press the Request a key it will enter its website and key in the e mail account to execute the Apply button and then get their product key from your e mail Step 4 Please copy the Product Key into this space Step 5 Press the Activate to enable this tool Step 1 Step 3 3 2 Step 1 Step 5 5 5 4 5 4 3 Step 1 Step 2 Step 4 4 4 4 4 4 4 4 4...

Страница 4: ... Step 2 Select the BACnet IP and BACnet Ethernet Step 3 Key in the BACNet IP Port Step 4 To make sure the the PC and BACNet IP device is linking to press the Refresh button toget the on line device Step 5 To select the BACNet IP device to press the OK button Step 2 Step 4 Step 1 Step 5 Step 3 ...

Страница 5: ...TND531 E0 Page 5 of 9 www cermate com 4 Press the Discover button and select all device to press Send 指令功能碼 讀取命令碼 0x01 0x02 0x03 0x04 寫入命令碼 0x05 0x06 0x15 0x16 ...

Страница 6: ...Sample the object ID is 9999 and this ID is the node address of the PM software setting Note The node address of the PM Designer software Before Ver1 2 57 is 0 32767 Please setting the object ID to 0 32767 Device AV1 456 000 Floating Point ...

Страница 7: ...TND531 E0 Page 7 of 9 www cermate com HMI Settings Select Device Server Honeywell BACnet IP Protocol Setting HMI IP address to 192 168 1 34 and the Node Address 9999 Object I D ...

Страница 8: ...TND531 E0 Page 8 of 9 www cermate com Bit Device Word Device Thank You ...

Страница 9: ...vin cermate com Worldwide 886 910011914 Linda cermate com Cermate Technologies Shanghai Inc 屏通科技 上海 有限公司 Phone 86 21 51758590 2 FAX 86 21 51758589 E mail service01 sh cermate com Shenzhen Cermate Technologies Inc 屏通科技 深圳 有限公司 Phone 86 755 83562179 FAX 86 755 83562294 E mail sa cermate cermate com Cermate Technologies Inc 台湾 屏通科技股份有限公司 7F 1 No 168 Lien Cheng Road Chung Ho City Taipei Taiwan 235 R O...

Отзывы: