FibeAir® RFU-C
Installation Guide
Ceragon Proprietary and Confidential
Page 77 of 93
9.6
Installing an RFU-C
– NEC Adapter (PASOLINK NEO)
Note:
These instructions are
relevant for antennas up to 4 feet.
List of Items
Item
Description
Quantity
1
RFU-C - NEC ADAPTOR PLATE
1
2
SCREW AND WASHER ASSEMBLY, SOCKET HEXAGON HEAD CAP,
WITH HELICAL WASHER,
SS, ~DIN 912-M6x16-A2-70 and ~DIN 127-B6-A2-70
4
Required Tools
5 mm offset hexagon key wrench
Procedure
1 Make sure there are two O-Rings, one on the NEC antenna and one on the
RFU-C - NEC adapter plate.
2 Use the Location Pin (shown in the figures below) to guide the circular
part of the RFU-C - NEC adapter plate onto the circular part of the NEC
antenna.
3 Fasten the RFU-C - NEC adapter to the NEC Shenglu or Mobi antenna using
four screws and four washers.
Note:
Fasten the screws diagonally. First fasten the upper right
screw and lower left screw, and then fasten the upper left
screw and lower right screw.