Note:
Connect the smaller cable shoe to the earthing terminal.
The earthing cable must be at least 4mm2 (AWG11).
If installing multiple IDUs in the rack, connect their earthing
terminals in series using the IDU earthing jumper, part
number UWML 6761.
Tighten the earth terminal screw (with washer) to torque
2.9 Nm.
Ensure the earthing cable/jumper does not prevent
extracting the fan unit from the IDU chassis.
7 Connect the XCVR-IDU cable between the XCVR plug on the RMC and the
XCVR.
Connecting the XCVR-IDU Cable
8 If you have mounted two XCVR devices, connect the second XCVR-IDU
cable.
9 Connect the IDU power cable, part number CBL-PWR-OE-OE-16A-5M.
Connect the bared ends to the outputs of fuse number 1 and the power
cable connector to the power input socket of the PDC in the IDU chassis.
IDU Power Cable