Ceragon Evolution IP-20LH Скачать руководство пользователя страница 1

 

 

Copyright © 2014 by Ceragon Networks Ltd. All rights reserved. 

 

 

Evolution® IP-20LH 

Installation Guide 

Part ID: BM-0299-0 
Doc-00043449 Rev A.01 
August 2014 

Содержание Evolution IP-20LH

Страница 1: ...Copyright 2014 by Ceragon Networks Ltd All rights reserved Evolution IP 20LH Installation Guide Part ID BM 0299 0 Doc 00043449 Rev A 01 August 2014...

Страница 2: ...ive holders Statement of Conditions The information contained in this document is subject to change without notice Ceragon Networks Ltd shall not be liable for errors contained herein or for incidenta...

Страница 3: ...Interface Card 24 2 7 Power Distribution Card PDC 25 2 8 Fans Module 27 2 9 Filter Tray Overview 28 2 10 XCVR 29 2 10 1XCVR Power Options 29 2 10 2XCVR Identification Label 29 3 Preparing for Installa...

Страница 4: ...g the Fans Drawer 54 5 4 1 Installing the Fans Drawer 54 5 4 2 Replacing the Fans Drawer 55 5 5 Installing and Replacing a Filter Unit 56 5 5 1 Installing the Filter Unit 56 5 5 2 Removing the Filter...

Страница 5: ...n Outs 92 10 1 TCC Interfaces and Pin Outs 92 10 2 Ethernet Line Card Interfaces and Pin Outs 94 10 3 TDM LIC T16 16 x E1 95 10 4 TDM LIC T155 1 x ch STM 1 98 11 Specifications 99 11 1 Environmental S...

Страница 6: ...e to strong high frequency electromagnetic fields may cause thermal damage to personnel The eye cornea and lens is easily exposed Any unnecessary exposure is undesirable and should be avoided In radio...

Страница 7: ...sconnected from the transmitter before it is disconnected from the receiver When the cable is reconnected it must be connected to the receiver before it is connected to the transmitter Special Require...

Страница 8: ...nt connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing and to a cable distribution system...

Страница 9: ...toutes les alimentations lectriques Bruit de machine d ordre 3 GPSGV le plus haut niveau de pression sonore s l ve 70 dB A au maximum dans le respect de la norme ISO EN 7779 Allgemeine Vorsichtsma nah...

Страница 10: ...tion of Hazardous Toxic Substances Component Hazardous Substance Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated Biphenyls PBB Polybrominated Diphenyl Ethers PBDE PCB Circuit Mo...

Страница 11: ...This manual provides instructions for the installation of the complete Evolution IP 20LH system Some features described in this manual may not be available in the current release Consult the Release...

Страница 12: ...tem s ultra high power transmitter transmits the highest power in the industry and can reach longer distances using smaller antennas For maximum power efficiency the Evolution IP 20LH incorporates a d...

Страница 13: ...er De Duplication RMC E also supports XPIC with up to 4201 QAM modulation The RMC E has two variants It can be ordered either as an RMC only or as an RMC integrated with an STM1 OC3 RST interface Line...

Страница 14: ...rface Cards LICs can be added to provide additional traffic interfaces Ethernet and TDM LICs can be used A 2RU chassis can contain up to ten LICs up to two of which can be Ethernet LICs A 1RU chassis...

Страница 15: ...the numbered slots to the different cards is described in the tables that follow 1RU Chassis Slot Numbering 2RU Chassis Slot Numbering Chassis Slot Population Guidelines Slot Card Illustration Usage 1...

Страница 16: ...RU In a redundant TCC configuration the backup TCC is placed in slot 11 12 2RU Slot 12 is used to hold Ethernet LICs PDC1 1RU and 2RU PDC2 2RU A single feed or dual feed input PDC is placed in this sl...

Страница 17: ...assis Slot Population Recommendations per Card Type Card Type 1RU Chassis 2RU Chassis TCC B MC 1 1 11 a second TCC can only be used when TCC protection is enabled PDC PDC 1 PDC 1 PDC 2 LIC X E4 Elec O...

Страница 18: ...ernet traffic and two FE interfaces for management traffic The TCC is responsible for the following functions CPU Chassis management Switch aggregation Synchronization TCC Detailed View TCC LEDs Synch...

Страница 19: ...also supports XPIC with up to 4201 QAM RMC E also includes an STM 1 interface for both radio and native TDM support RMCs can be placed in any slot except the TCC slot slot 1 and in a 2RU chassis slot...

Страница 20: ...RFU Red XCVR failure Blinking Red An RF loopback has been activated and the result is Failed RFU Orange Loss of communication between the IDU and the XCVR RFU Green The XCVR is functioning normally Bl...

Страница 21: ...rfaces LIC X E4 Opt 4x GE with 1 GbE combo interface and 3 GbE optical SFP interfaces 2 4 1 LIC X E4 Elec The LIC X E4 Elec has the following interfaces 1 x GbE combo interface SFP1 GbE1 3 x GbE elect...

Страница 22: ...e following interfaces 1 x GbE combo interface SFP1 GbE1 3 x GbE optical SFP interfaces LIC X E4 Opt Detailed View The LIC X E4 Opt provides the following LED ACT Indicates the card status LIC X E4 Op...

Страница 23: ...5 1 LIC T16 16 x E1 Line Interface Card LIC T16 Detailed View The LIC T16 provides the following LEDs ACT Activity indicator E1 DS1 Interface indicator LIC T16 LEDs LIC T16 LEDs LED Color Explanation...

Страница 24: ...the following LEDs ACT Activity indicator STM1 OC3 Interface indicator LIC T155 LEDs LIC T155 LEDs LED Color Explanation ACT Red The LIC is not functioning normally ACT Green The LIC is functioning no...

Страница 25: ...tion If the voltage goes below 38V the LED displays Red When the voltage returns to 40V or higher the Red indication goes off and the Green indication reappears The PDC includes reverse polarity prote...

Страница 26: ...l Feed PDC LEDs LED Color Explanation ACT Red The input power to the PDC has gone below 38V and not yet returned to at least 40V or higher ACT Green The input power to the PDC has not gone below 38V o...

Страница 27: ...draw air into one side of the chassis and push the air through the chassis and out the other side Fans Module Detailed View The fan speed increases and decreases in response to the temperature inside...

Страница 28: ...de Ceragon Proprietary and Confidential Page 28 of 101 2 9 Filter Tray Overview A filter is offered as optional equipment If a filter tray is not ordered the chassis is equipped with a blank filter sl...

Страница 29: ...o deliver high transmit power with low power consumption The Evolution XCVR supports Space Diversity by means of IF Combining The Evolution XCVR provides a range of modulations from QPSK to 4201 QAM f...

Страница 30: ...have arrived Inspect for any damage on the cases and equipment Report any damage or discrepancy to a Ceragon representative by e mail or fax 3 3 Unpacking Equipment at the Site The equipment is packed...

Страница 31: ...bed in this manual these items must be used to comply with the relevant regulations 3 4 Verifying Initial Hardware Configuration Before installing the IDU in the rack verify placement of the following...

Страница 32: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 32 of 101 1RU IDU Chassis Rear View 2RU IDU Chassis Front View 2RU IDU Chassis Rear View...

Страница 33: ...and out the right side IP 20LH Air Flow To ensure that the IP 20LH maintains a proper operating temperature you must ensure that the air flow is unimpeded Make sure to install the chassis level in the...

Страница 34: ...at does not contain a card 4 2 Mounting the IDU Chassis in the Rack This procedure is for both 1RU and 2RU chassis Note that there are two possible ways to install an Evolution IP 20LH chassis Standar...

Страница 35: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 35 of 101 2RU IDU Chassis in Rack Front Mount 1RU IDU Chassis in Rack Standard Mount...

Страница 36: ...dard Mount 4 2 1 Standard Mount to Front Mount Conversion Loosen the four screws that hold the bracket to the chassis and retighten them in the new position as shown below The same procedure is perfor...

Страница 37: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 37 of 101 2 Remove the bracket 3 Align the bracket with the holes in the center of the chassis 4 Replace all four screws...

Страница 38: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 38 of 101 5 Retighten the screws in the new position...

Страница 39: ...of 101 4 3 Grounding the Chassis Connect a grounding wire to the single point stud shown in the figures below and then to the rack using a single screw and two washers The size of the grounding wire m...

Страница 40: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 40 of 101 2RU Chassis Grounding p...

Страница 41: ...t the chassis grounding cable 4 Since the chassis fully populated is heavy it may be convenient to remove cards prior to removing chassis from the rack 5 Unscrew the chassis from the rack four screws...

Страница 42: ...an IP 20N chassis is delivered with an IVM already installed However if you are required to install or replace an IVM follow these instructions On the rear side of the chassis place the IVM in front o...

Страница 43: ...01 4 6 Replacing an IVM In the event that an IVM must be replaced follow these instructions 1 Loosen the two screws that secure the IVM in its place and gently pull out the IVM Replacing an IVM 1RU Re...

Страница 44: ...d configuration The SD card is packaged in a compartment in the front portion of the TCC package It is placed in such a way that you can view the label and serial number of the SD card before opening...

Страница 45: ...Proprietary and Confidential Page 45 of 101 Inserting an SD Card into a TCC When the SD card is inserted properly it should click into place The figure below shows an SD card properly inserted in its...

Страница 46: ...arefully insert the new TCC into slot 1 Ensure that the TCC enters the guides inside the chassis and gently press the TCC to enter the internal connectors without the use of excessive force 2 Make sur...

Страница 47: ...s current software and configuration To remove the SD card press down gently on the card and slide the card out of its socket on the upper left side of the TCC 2 Disconnect all cables not shown on th...

Страница 48: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 48 of 101 9 Re insert the SD card that you removed from the old TCC...

Страница 49: ...es and guidelines about slot placement refer to Slot Population Guidelines on page 15 5 2 1 Inserting an RMC or LIC into the Chassis 1 Carefully insert the new card Ensure that the card enters the gui...

Страница 50: ...r LIC 1 Disconnect all cables not shown on the card to be replaced 2 Unscrew the two captive screws that secure the card to the chassis A screwdriver may be used if necessary to unscrew the screws 3 R...

Страница 51: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 51 of 101...

Страница 52: ...RU chassis the first PDC must be installed in PDC Slot 1 Optionally you can install a second PDC in PDC Slot 2 For slot numbering refer to Slot Population Guidelines on page 15 5 3 2 Installing a PDC...

Страница 53: ...nnect the power cable not shown on the PDC to be replaced 2 Unscrew the two captive screws that secure the PDC to the chassis A screwdriver may be used if necessary to unscrew the screws 3 Carefully s...

Страница 54: ...chassis If you need to install or replace the fans drawer use the following instructions 5 4 1 Installing the Fans Drawer 1 Carefully insert the fans drawer in the right vertical slot Ensure that the...

Страница 55: ...the Fans Drawer 1 Unscrew the two captive screws that secure the fans drawer to the chassis A screwdriver may be used if necessary to unscrew the screws 2 Carefully remove the drawer from the chassis...

Страница 56: ...can be installed in the IP 20N The filter unit consists of a filter tray and a filter foam The filter foam needs to be changed or cleaned from time to time depending on the environmental conditions Fo...

Страница 57: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 57 of 101 2 Slide the filter tray into the filter slot in the chassis 3 Fasten the captive screw manually...

Страница 58: ...on Proprietary and Confidential Page 58 of 101 5 5 2 Removing the Filter Foam The filter tray is secured to the chassis by means of a captive screw no ejectors 1 Unscrew the captive screw 2 Remove the...

Страница 59: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 59 of 101 3 Remove the filter foam from the filter tray...

Страница 60: ...Connection The IDU chassis is mounted in an equipment rack see Mounting the IDU Chassis in the Rack on page 34 and XCVR s are mounted on the XCVR mounting plate in the same equipment rack This procedu...

Страница 61: ...dential Page 61 of 101 Mating the connectors of the XCVR with the sockets on the mounting plate XCVR Mounted 2 Secure the XCVR to the mounting plate by tightening the four screws evenly until the unth...

Страница 62: ...2 AWG7 i Remove the cable lug from one end of the cable and strip that end ii Connect the cable to the earth terminal block XCVR Earthing Cable 5 Connect an earth jumper between the earth terminal blo...

Страница 63: ...earth terminal screw with washer to torque 2 9 Nm Ensure the earthing cable jumper does not prevent extracting the fan unit from the IDU chassis 7 Connect the XCVR IDU cable between the XCVR plug on...

Страница 64: ...and Confidential Page 64 of 101 The fuses are numbered as follows Fuse Numbering Single IDU Single Power Feed 10 If the PDC has a dual power feed connect another IDU power cable between fuse number 1...

Страница 65: ...the second chassis Two IDUs Single Power Feed 12 If the PDCs have dual power feed connect IDU power cables between fuse number 11 and the power input socket of one PDC and between fuse number 12 and t...

Страница 66: ...e part number AWZP36 to the inputs of fuse number 11 and to a second 48 VDC power source 16 If there is a second IDU chassis in the equipment rack and both have dual power feed such that both fuses 11...

Страница 67: ...IDU cables are marked with two digits on each end The first is the system number 1 for the first system in the rack etc The second digit is the channel number Cable Marking Note There are three diffe...

Страница 68: ...e use of up to eight XCVRs on a single polarization Two Branching Boxes with Dual Polarized Antennas It is possible to connect two boxes with dual polarized antennas enabling up to four XCVRs per pola...

Страница 69: ...s Place the sling rope between the XCVRs and the branching box as close to the center of the branching box as possible Hoisting 2 XCVRs 6 2 2 Mounting XCVRs on a Pole Use the pole mount kit part numbe...

Страница 70: ...sired Position 3 Push the branching box close to the pole and thread the U shaped clamps around the pole and through the mounting handles on the branching box Installing U Shaped Clamps Note For a pol...

Страница 71: ...Mount the flexible waveguide as follows i Remove the waveguide flange cover plate on the bottom of the branching box Removing Waveguide Flange Cover one removed one in place Note The second waveguide...

Страница 72: ...ach other v Mount the flexible waveguide on the antenna waveguide flange using 8 screws washers and nuts vi Mount the flexible waveguide on the branching box waveguide flange using 8 screws washers an...

Страница 73: ...Cables ii Connect an earthing cable part number UWML6505 to the earthing terminal on the bottom of the branching box Branching Box Earthing Cable Note Earthing cables must be at least 10mm2 AWG7 The...

Страница 74: ...in the right corner of the XCVRs Bushing Installed Note Make sure the bushing completely covers the connector base and the rounded part of the XCVR housing ii Thread a neoprene sleeve over the cable c...

Страница 75: ...etration of water Do not stretch the XCVR IDU cable when sliding the neoprene sleeve XPIC systems To avoid extra configuration for XPIC the cables should not differ in length by more than 3 meters on...

Страница 76: ...arthing Kit on XCVR IDU Cable Note Mount the earthing kit on the cable near the cable inlet at the station house shelter It is recommended to mount an additional earthing kit within 1m of the XCVR For...

Страница 77: ...m expandable to 1 1 The same procedure applies to larger systems 1 Power down the system by turning off the fuses Note The traffic on this terminal will be interrupted 2 Remove the currently mounted X...

Страница 78: ...ulator flange cover plates by unscrewing the four screws on each cover plate RCVR flange XMTR flange and space diversity flange on space diversity systems Removing Circulator Flange Cover Plates Note...

Страница 79: ...ounted as shown in the figure above 6 Secure the filters using the screws you removed from the cover plates 7 Mount the XCVR interface plate by securing it to the support bar with two screws mounted f...

Страница 80: ...w XCVR IDU and power cables for the new channel 10 Remount the front plates and secure all the screws you removed previously 11 Pull the XCVR IDU cables through the holes XCVR IDU Cables 12 Mount two...

Страница 81: ...es not contain a card must contain a blank panel There are three types of blank panels corresponding to the three slot sizes in an IP 20N chassis Blank Panel TCC Blank Panel PDC Blank Panel RMC LIC To...

Страница 82: ...d or dual feed PDC The power cable connector is included with the PDC The following power cables are available for use with a 1RU IP 20LH unit Ceragon Part Number Marketing Model Marketing Description...

Страница 83: ...101 8 1 For a 2RU Chassis 1 Verify that the wiring is according to the correct polarity 2RU Chassis PDC Polarity 2 Plug the power connector into the PDC and tighten the two captive screws on the sides...

Страница 84: ...on the connector 3 Verify that the wiring is according to the correct polarity Correct Wiring on a 1RU Chassis 4 Insert the wires into the connector 5 Secure the wires in the connector with the screw...

Страница 85: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 85 of 101 Connecting the Power Cable in a 2RU Chassis Dual Feed PDC...

Страница 86: ...on Remove all power form the unit for servicing Important Make sure to use a circuit breaker to protect the circuit from damage by short or overload In a building installation the circuit breaker shal...

Страница 87: ...Evolution IP 20LH Installation Guide Ceragon Proprietary and Confidential Page 87 of 101 Power Supply Grounding 2RU Chassis...

Страница 88: ...s refer to the Evolution IP 20LH User Guide DOC 00043450 9 1 Establishing a Connection You can connect to the IP 20LH unit via a Serial or a LAN connection 9 1 1 Connecting to the Unit with a Serial C...

Страница 89: ...e IP 20LH unit The default chassis IP address is 192 168 1 1 For example you can set the PC or laptop address to 192 168 1 10 and the subnet mask to 255 255 255 0 Note the initial settings before chan...

Страница 90: ...d Confidential Page 90 of 101 9 2 Logging On 1 Open an Internet browser Internet Explorer or Mozilla Firefox 2 Type in the default IP address 192 168 1 1 in the Address Bar Login Window 3 Enter the fo...

Страница 91: ...e of the hop may be lost By default all elements have the same IP settings IP address 192 168 1 1 Subnet mask 255 255 255 0 Note After the new IP address is set the contact with the element will be lo...

Страница 92: ...aces The FE management interfaces are labeled MGMT1 and MGMT2 These interfaces are 100BaseT with auto negotiation and auto crossover A TCC also contains the following interfaces One RJ 45 terminal int...

Страница 93: ...8 NC External Alarms DB 9 Pin no Description 1 External input alarm 1 2 External input alarm 2 3 External input alarm 3 4 External input alarm 4 5 External input alarm 5 6 Relay 1 normally closed pin...

Страница 94: ...ard Interfaces and Pin Outs An LIC X E4 Elec 4x GE contains 1 GbE combo interface and 3 GbE electrical RJ 45 interfaces An LIC X E4 Opt 4x GE contains 1 GbE combo interface and 3 GbE optical SFP inter...

Страница 95: ...r Type 1 OUT TIP1 Ch1 Tx TWISTED PAIR 35 OUT RING1 2 OUT TIP2 Ch2 Tx TWISTED PAIR 36 OUT RING2 3 OUT TIP3 Ch3 Tx TWISTED PAIR 37 OUT RING3 4 OUT TIP4 Ch4 Tx TWISTED PAIR 38 OUT RING4 5 OUT TIP5 Ch5 Tx...

Страница 96: ...0 OUT RING16 19 IN TIP1 Ch1 Rx TWISTED PAIR 53 IN RING1 20 IN TIP2 Ch2 Rx TWISTED PAIR 54 IN RING2 21 IN TIP3 Ch3 Rx TWISTED PAIR 55 IN RING3 22 IN TIP4 Ch4 Rx TWISTED PAIR 56 IN RING4 23 IN TIP5 Ch5...

Страница 97: ...PAIR 65 IN RING13 32 IN TIP14 Ch14 Rx TWISTED PAIR 66 IN RING14 33 IN TIP15 Ch15 Rx TWISTED PAIR 67 IN RING15 34 IN TIP16 Ch16 Rx TWISTED PAIR 68 IN RING16 17 SHELL SHIELD 18 SHELL SHIELD 51 SHELL SH...

Страница 98: ...contains 1 x ch STM 1 connector and an RJ 45 synchronization interface for clock input and output The 1 x ch STM 1 interface uses an optical SFP connector 1 x ch STM 1 Connector Synchronization Inter...

Страница 99: ...ted successfully with limited margins Note Cold startup requires at least 5 C 23 F Humidity 5 RH to 95 RH 11 2 Environmental Specifications for XCVR Temperature 33 C 27 F to 55 C 131 F Temperature ran...

Страница 100: ...male to IDU and XCVR IDU Card and Tray Weights PDC 0 3 kg RMC 0 34 kg LIC 0 5 kg TCC 1 5 Fans Drawer 1RU 0 3 kg Fans Drawer 2RU 0 6 kg Evolution XCVR Mechanical Specifications XCVR Dimensions Height 2...

Страница 101: ...Card Type Configuration Power W Comments TCC 25 W RMC 9 W Includes STM 1 OC 3 SFP module LIC X E4 Elec 4x GE 9 W LIC X E4 Opt 4x GE 9W LIC T16 16 x E1 17 W LIC T155 1 x ch STM 1 25 W LIC STM1 OC3 RST...

Отзывы: