Century CC1212-XLi Скачать руководство пользователя страница 3

2 • Owner’s manual - Model. CC1212-XLi 

• 

If using a generator, you must ensure you use a surge protector to protect the charger from 

voltage spikes.

• 

The charger must not be used or played with by infirm persons or children. Also keep away from 

pets.

• 

Turn engine and or charger off before disconnecting a battery*

 

* In some vehicles, ignition may be required to be placed in accessory mode where electronic 

memory minder is present.

MAIN FEATURES 

•  The battery charger is easy to use and requires no technical experience.

•  It is a selectable automatic smart battery charger & maintainer with reconditioning 

mode that is fully microprocessor controlled with safety timers at every stage.

•  9 Stage process for Lead-acid type batteries (GEL, AGM/FLOODED/EFB, CALCIUM SMF)

 

1 - Qualification - Battery condition check

 

2 - Battery rejuvenation (recondition mode)

 

3 - Soft start charging

 

4 - Bulk charging

 

5 - Absorption charging

 

6 - Equalisation charging

 

7 - Battery analysis

 

8 - Float mode 

 

9 - Long term maintenance pulse charge. Recharge Cycle every 21 Days.

•  7 Stage process for Lithium-ion (LiFePO4) type batteries

 

1 - Lithium Activation

 

2 - Soft start charging

 

3 - Bulk charging

 

4 - Absorption stage 1

 

5 - Absorption stage 2

 

6 - Full

 

7 - Analysis

•  Battery condition analysis.

•  Battery voltage retention analysis.

•  Automatic diagnosis and charge: 

On power up, the charger will automatically diagnose 

the battery condition and determine if the rejuvenation mode (reconditioning) or charge 

cycle is required.

•  Selectable battery type.

•  Selectable charge rate / mode.

 

12A - Rapid Charge Mode:

 Uses maximum charging current (12 Amps) to ensure the  

fastest charge time.  You may hear the fan turn on during this mode. 

 

8A - Silent Charge Mode: 

Charges at a reduced charge rate (8 Amps) and the cooling 

fan is not required. 

 

1A - Maintenance Mode:

 Ideal and recommended for long term maintenance 

charging or for charging smaller batteries.  NOTE: When used in maintenance mode, 

please check that the application’s current draw does not exceed the charging 

current.

• 

LFP Wake Up - Power Supply: 

13.8V 12A Max Power Supply Mode which is time limited 

for 24 Hours before automatically switching back to LITHIUM (LFP) Charging Mode.

Содержание CC1212-XLi

Страница 1: ...OWNER S MANUAL Model CC1212 XLi AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...yes hold eyelids apart and flush the eye continuously with running water Continue flushing for at least 15 minutes or until advised to stop by poisons information centre national poisons centre or doc...

Страница 3: ...tenance pulse charge Recharge Cycle every 21 Days 7 Stage process for Lithium ion LiFePO4 type batteries 1 Lithium Activation 2 Soft start charging 3 Bulk charging 4 Absorption stage 1 5 Absorption st...

Страница 4: ...s to a safe level the charger will resume normal charging SAFETY TIMER PROTECTION The charger has safety timers for every stage If the battery voltage doesn t reach a certain voltage within a specific...

Страница 5: ...r charging requirements Model No CC1212 XLi Charge Rate 1A 8A 12A Charging 3 20Ah 24 160Ah 36 240Ah Maintaining 100Ah 240Ah 360Ah These figures are based on 5 to 30 of battery Ah rating For optimum ch...

Страница 6: ...12V DC Input Voltage 220 240V AC 1 8A 175W Input Frequency 50Hz Charge Voltage Gel 14 1V AGM Flooded EFB 14 4V SMF Calcium 14 7V LITHIUM LFP 14 4V Equalising Voltage Gel 14 3V AGM Flooded EFB 14 6V S...

Страница 7: ...atteries co nz battery charging for advice on which Battery Type and Charge Rate settings to select Check the Battery Electrolyte levels For maintainable batteries remove the vent caps and if necessar...

Страница 8: ...ualification detected that the battery was in poor condition the patented rejuvenation process will begin automatically During the rejuvenation process a high voltage equalising and peak pulse recondi...

Страница 9: ...ltage drops too quickly during the analysis mode this means the battery is probably faulty If the battery analysis failed this is indicated by the Green Full LED flashing 8 Float Mode Thisstageallowsy...

Страница 10: ...13 8V 12A Max 1A 8A 12A selectable If the Lithium Activation signal isn t waking up your battery BMS you may use this feature to wake it up With the LITHIUM LFP Battery Type selected press and hold th...

Страница 11: ...harge Time Out 13 0V ON ON Flash OFF OFF ON ON Flash Reverse Polarity Short Circuit OFF OFF OFF OFF OFF ON ON ON Sulphation Shorted cell fail Flash Flash Flash Flash OFF ON ON ON Over Temperature prot...

Страница 12: ...se charge for long term maintenance to ensure the battery is in optimal condition EQUALISATION Restores full capacity to batteries by removing acid stratification SMART 9 STAGE LEAD ACID BATTERY CHARG...

Страница 13: ...ent AC Power Point which you know is working Charger has no DC output Fault Red LED is ON Output is short circuited Reverse polarity protection Loose bad connection to the battery Check DC connection...

Страница 14: ...e rate selected might be too low for the battery Switch charger off and on and try again or try a higher charge rate setting providing it doesn t exceed the maximum charge limit for your battery Note...

Страница 15: ...proof of purchase and warranty It is recommended that products are returned to point of purchase or be sent by registered mail as Century Yuasa Batteries accepts no responsibility liability for goods...

Страница 16: ...pproval No GMA 511817 EA Century Yuasa Batteries Pty Ltd 37 65 Cobalt Street Carole Park QLD 4300 Australia T 1300 362 287 www centurybatteries com au Century Yuasa Batteries NZ Ltd 259 Church Street...

Отзывы: