4
Cast iron flue collar installation:
1.
Peel off the tape from the back
of the gasket and attach the
gasket to the rope groove at
the back of the flue collar;
2.
Mount flue collar on top of the
stove. Make sure that the
damper holes on each side of
the flue collar are parallel to the
back of the stove;
3.
Fix the flue collar with the
hardware supplied;
4.
Install the flue damper inside
the flue collar as illustrated.
Firebricks installation:
1. Install the back and side
firebricks.
2. Install the bottom firebricks
17 bricks
4½’’ x 9’’ x 1¼’’
2 bricks
4½’’ x 4½’’ x 1¼’’