Centurion WM 2.5 Скачать руководство пользователя страница 8

for the hot taps to be adjusted. Turning it clockwise increases
the temperaJure.

Pressure gauge

This indicates the central heating system

pressure. The red pointer will have been set by your Installer
and must not be moved. The white pointer indicates the actual
pressure, which will increase as the system warms up. Do not

operate the boiler if the pressure falls below 0.5 bar. If this
happens, contact your Service Engineer to have the system
re-pressurised.

Overheat Lockout reset button

If there is a burner control

malfunction,

or an interruption

in the power supply, the

overheat thermostat will switch the boiler off and the red

lockout neon will light. If the boiler continually goes to 'lockout'

a fault exists and you will need to call your Service Engineer.

Safety valve

The boiler is fitted with a safety valve to release

excess pressure from the system if it overheats. If water or
steam is discharged from the end of the pipe, switch off the
boiler and contact your Service Engineer.

Flue terminal

The flue terminal on the outside wall must not

be obstructed or damaged. In cold weather steam might
appear from the terminal this is quite normal for a high
efficiency boiler. In severe conditions check that the terminal

does not become blocked by snow.

Central heating system

The boiler is fitted with an automatic air vent which removes
air from the system as it leaves the boiler. Any air trapped in
the radiators needs removing by venting the radiators using
the vent screw at the top of the radiators. Only vent a radiator

if the top is cool and the bottom is hot. Excessive venting will
reduce the system pressure, so only vent when necessary and

check the system pressure as mentioned above.

Note: Your sealed system may incorporate a 'Top Up' vessel,

advice on how to use it should be obtained from your Installer.

Domestic hot water system.

The flow of water from the taps (hot or cold) depends upon the

mains water pressure, and in some homes it may not be
possible to use a number of taps at the same time.

The temperature of water leaving a hot tap depends on a lot of
variables, such as mains pressure, distance of the tap from

the boiler and the flow rate of the water leaving the tap. It may
take some time and experimenting

with the temperature

control (see below) and how far you open a tap to achieve the

results you require. Remember, if you open a hot tap fully it
may not supply water at such a high temperature as when you

only open it half way.
The temperature of the hot water leaving the boiler for the hot

taps can be increased by turning the hot water temperature
control knob (see Fig. 1) clockwise.

ROUTINE SERVICING

To ensure the continued efficient and safe operation of the
GlIPpliance,it is recommended that servicing is canrJed·out at

regular intervalS, the frequency of which will vary, depending

on the installation conditions and usage. Service inspection
once a year is recommended.
Servicing

must be completed

by a competent

(CORGI

registered) person.

CLEANING

To clean the appliance casing use a damp cloth and a little
detergent. Do not use an abrasive cleaner.

5"7030

Содержание WM 2.5

Страница 1: ...TURION 2 5 3 5 Wall Mounted Fan Assisted Gas Fired Instantaneous Combination Boiler s InstructIons Centurion WM 2 5 WM 3 5 G C No 47 13003 FOR NATURAL GAS ONLY Part No PL35984 ISSUE 2 DATE March 1997 57030 ...

Страница 2: ... 1 Method of operation 1 Gas Consumer Council 2 Boiler Clearances 2 Ventilation 2 Lighting the Boiler 2 To turn off the Boiler 3 Operation of Controls 3 Central Heating Timer Operation 3 General Notes and Care of your system 5 Servicing and Maintenance 6 Cleaning 6 Spare Parts and Service 6 57030 ...

Страница 3: ...flue The appliance has been designed for use on a sealed water central heating system and is suitable for use with natural gas only The appliance provides central heating at outputs between 8 8 kW 30 100 Btu h and 22 0 kW 75 000 Btu h Hot water is produced at outputs between 6 3 kW 21 600 Btu h and 27 7 kW 94 500 Btu h Incorporated within the appliance are a User adjustable controls for domestic h...

Страница 4: ...become obstructed TO LIGHT THE BOilER Refer to Figure 1 IF OPTIONAL TIMER IS FITTED a Ensure that the gas and water supplies are turned on the electricity supply to the boiler is off the Mains ON OFF switch is set to OFF the timer is correctly set refer to figure 2 and the room thermostat if fitted is set at the desired setting Set the central heating OFF ON TEMPERATURE CONTROL to the desired temp...

Страница 5: ... off the power and gas supply e g for a long absence it is necessary to drain the system OPERATING THE OPTIONAL HEATING TIMER IF FinED The electronic timer display 24 hr clock provides a permanent display of the time of day and day of the week If the boiler is switched off or its power supply interrupted a built in battery will operate the display and protect the programme of operating times etc D...

Страница 6: ...isappears press it again and it will reappear under Sunday If the button is kept pressed in it will quickly advance through the above sequence HR button Use this button to set the hours for the time of day and the on off times Keep the button pressed in to advance the time rapidly then press release it for individual hrs MIN button Use this button to set the minutes in the same manner as the HR bu...

Страница 7: ...e HR and MIN buttons to set the actual time for the end of the first heating period g Q Operations d to f can be repeated to give you up to eight heating periods in the selected group of days You do not need to use all of the switching modes Cl IMPORTANT You must use the DAY button to select the Q required day or groups of days for each on off period before setting the time for each on off period ...

Страница 8: ...ng the radiators using the vent screw at the top of the radiators Only vent a radiator if the top is cool and the bottom is hot Excessive venting will reduce the system pressure so only vent when necessary and check the system pressure as mentioned above Note Your sealed system may incorporate a Top Up vessel advice on how to use it should be obtained from your Installer Domestic hot water system ...

Страница 9: ...gineers In the unlikely event of a breakdown please contact Centurion on 01473 747472 or alternatively your installation or servicing company To help us provide you with a fast and efficient service please quote the boiler number and G C number This can be found on the label on the inside of the control panel door 57030 ...

Страница 10: ...previous issue CENTURION GAS PRODUCTS LTD PO Box 323 Ipswich IP1 5JB Tel 01473747472 Fax 01473747479 Centurion Gas Products policy is one of continuous research and development This may necessitate alterations to this specification ...