Centurion WM 2.5 Скачать руководство пользователя страница 6

®

button

Use this button to select the switching modes when

setting your central heating periods. A .:~ symbol will appear

at the right hand side of the display when a 'switch on' mode is
selected, this will disappear when a 'switch off' mode is
selected. A number (1 to 16) also appears in the display next

to the symbol, this indicates the number of the switching

mode.
Up to 8 'on' and 8 'off' switching modes can be selected.

Note

"

These must be selected in pairs with the same day or group of
days for each pair, ie 1st pair

=

1-on/2-off, 2nd pair

=

3-on/4-off

etc.

If the pairs are to be set for the whole week then all days must

be selected for each 'on'

&

'off' pair as they are set.

DAY button

Use this button to select the day of the week

when setting the timer. You also use this button to select

'groups' of days when setting your central heating periods. An

arrow is continuously visible on the display to indicate the day
of the week. When setting the operating times and choosing

the 'groups' of days, the arrows appear under each day in the

'group', these revert back to the single arrow under the day of

the week after setting the timer.
When using the day button, keep press/releasing it and the
arrow under the day of the week will advance through the
days, after the single days of the week the 'groups' of days will
appear. Five days (Monday to Friday), then weekends
(Saturday and Sunday), then six days (Monday to Saturday),

then all seven days. If the button is pressed again the arrow
disappears, press it again and it will reappear under Sunday.

If the button is kept pressed in, it will quickly advance through

the above sequence.

HR button

Use this button to set the hours for the time of day

and the 'on', 'off' times. Keep the button pressed in to advance
the time rapidly, then press/release it for individual hrs.

MIN button

Use this button to set the minutes, in the same

manner as the HR button previously described.

*+

button

Use this botton to select the Advance function

which will cause the timer to advance to the next 'on' or 'off'

period. The display will show either the

*+

symbol when you

switch to 'off' during a programmed 'on' period or both the

*+

and .:~symbols will show when you switch to 'on' during a

programmed 'off' period. The timer will return to the next
programmed 'on' or 'off' mode on completion.

R button

Use this button to clear any previous programmes,

using the tip of a pencil. The display will reset to 0.00 and
Monday will be selected. The dispiay will flash until the timer

setting switch is set toe:> and the correct date/time entered
(see next section).

TO SET THE ELECTRONIC

TIMER (SEE FIG. 2)

The timer is supplied with the following factory set default
times (available 7 days)

Program 1 On 06.30
Program 2 Off 08.30
Program 3 On 12.00
Program 4 Off 12.00
Program 5 On 16.30
Program 6 Off 22.30

These may be used or the timer can be re-programmedas:follows:

1) Press the R button to clear any previous programmes from

the memory. The display will reset and start to flash.
Set the time of day and day of the week as follows:
2(a) Set the timer setting switch to e:>and the display will stop
flashing. (b) Press the HR and MIN buttons to set the actual

57030

Содержание WM 2.5

Страница 1: ...TURION 2 5 3 5 Wall Mounted Fan Assisted Gas Fired Instantaneous Combination Boiler s InstructIons Centurion WM 2 5 WM 3 5 G C No 47 13003 FOR NATURAL GAS ONLY Part No PL35984 ISSUE 2 DATE March 1997 57030 ...

Страница 2: ... 1 Method of operation 1 Gas Consumer Council 2 Boiler Clearances 2 Ventilation 2 Lighting the Boiler 2 To turn off the Boiler 3 Operation of Controls 3 Central Heating Timer Operation 3 General Notes and Care of your system 5 Servicing and Maintenance 6 Cleaning 6 Spare Parts and Service 6 57030 ...

Страница 3: ...flue The appliance has been designed for use on a sealed water central heating system and is suitable for use with natural gas only The appliance provides central heating at outputs between 8 8 kW 30 100 Btu h and 22 0 kW 75 000 Btu h Hot water is produced at outputs between 6 3 kW 21 600 Btu h and 27 7 kW 94 500 Btu h Incorporated within the appliance are a User adjustable controls for domestic h...

Страница 4: ...become obstructed TO LIGHT THE BOilER Refer to Figure 1 IF OPTIONAL TIMER IS FITTED a Ensure that the gas and water supplies are turned on the electricity supply to the boiler is off the Mains ON OFF switch is set to OFF the timer is correctly set refer to figure 2 and the room thermostat if fitted is set at the desired setting Set the central heating OFF ON TEMPERATURE CONTROL to the desired temp...

Страница 5: ... off the power and gas supply e g for a long absence it is necessary to drain the system OPERATING THE OPTIONAL HEATING TIMER IF FinED The electronic timer display 24 hr clock provides a permanent display of the time of day and day of the week If the boiler is switched off or its power supply interrupted a built in battery will operate the display and protect the programme of operating times etc D...

Страница 6: ...isappears press it again and it will reappear under Sunday If the button is kept pressed in it will quickly advance through the above sequence HR button Use this button to set the hours for the time of day and the on off times Keep the button pressed in to advance the time rapidly then press release it for individual hrs MIN button Use this button to set the minutes in the same manner as the HR bu...

Страница 7: ...e HR and MIN buttons to set the actual time for the end of the first heating period g Q Operations d to f can be repeated to give you up to eight heating periods in the selected group of days You do not need to use all of the switching modes Cl IMPORTANT You must use the DAY button to select the Q required day or groups of days for each on off period before setting the time for each on off period ...

Страница 8: ...ng the radiators using the vent screw at the top of the radiators Only vent a radiator if the top is cool and the bottom is hot Excessive venting will reduce the system pressure so only vent when necessary and check the system pressure as mentioned above Note Your sealed system may incorporate a Top Up vessel advice on how to use it should be obtained from your Installer Domestic hot water system ...

Страница 9: ...gineers In the unlikely event of a breakdown please contact Centurion on 01473 747472 or alternatively your installation or servicing company To help us provide you with a fast and efficient service please quote the boiler number and G C number This can be found on the label on the inside of the control panel door 57030 ...

Страница 10: ...previous issue CENTURION GAS PRODUCTS LTD PO Box 323 Ipswich IP1 5JB Tel 01473747472 Fax 01473747479 Centurion Gas Products policy is one of continuous research and development This may necessitate alterations to this specification ...