Group & volume settings

Figure 7 Entry Panel Selector Switch

A

B

A

B

C

D

   The volume setting depends on the number of handsets connected to the system. 

1-or 2-BUTTON Entry panel configuration:
With the entry panel powered up, hold the top and bottom buttons down simultaneously for 5 seconds 
(5  beeps).  After  the  fifth  beep,  release  the  buttons.  A  confirmation  tone  will  then  be  heard  for  2 

Figure 6 Entry Panel Selector Switch

2

1

A

B

seconds. The entry panel is now in Configuration Mode, and will be for 10 seconds before it times out. 
While in this mode, there are two options available to the user:
· Press the top button (one beep will be heard) to set the entry panel as a one-button unit, where each 
button rings both groups of handsets
Or 
· Press the bottom button (two beeps will be heard) to set the entry panel as a two-button unit, where 
the top button rings group “A” handsets and the bottom button rings group “B” handsets.
On power up, the entry panel will beep either once or twice to indicate the configuration selected (one 
beep for a one-button and two beeps for a two-button entry panel)
Handset call group selector switch and volume control

Each handset is fitted with a selector switch(C) to allow the group number for the specific handset to 
be set. Set the switch depending on which group, (A) or (B) the respective handset is required to be 
linked.

Adjust the speech volume at the handset to approximately 75% by adjusting the control knob (D). 
Clockwise rotation increases the volume.

Check Functions

Press the gate/door release pushbutton on each handset and check that the gate/door adjacent to 
each entry panel operates.

Содержание POLOphone

Страница 1: ...AUDIO INTERCOM SYSTEMS TM POLOphone installation manual ...

Страница 2: ... to any component in the system Other features Using the same two wire bus each handset can independently operate the door lock or gate motor linked to each entry panel The entry panel is provided with a potential free normally open contact to operate either a gate motor or in series with a separate power supply to activate a door lock An auxiliary potential free normally open pushbutton is also p...

Страница 3: ...m the ringing at the handset s When lifting the handset voice communication can take place between the entry panel and the handset If any of the other handsets in the system are picked up while this communication is taking place there will be common communication with these handsets A dedicated call button is provided on the handset to call the other group of handsets Any handset in one group will...

Страница 4: ...ion Humidity Yes LED terminals on PCB 470Ohm in line resistor Requires separate wiring to 2 wire bus Potential free normally open contact Requires separate wiring to two wire bus Contact rating 2A 12V DC AC Max 150m Refer to cable thickness on page 7 2A 12V AC DC Potential free normally open contact at entry panel Door lock requires separate power supply wired in series with contact 20 C to 50 C C...

Страница 5: ...of the entry panel Conduit box mounting plate Simplifies the installation where a conduit wall box has been provided for mounting the handset The 4 x 2 backing box conduit box mounting plate replaces the existing box plate and provides the necessary fixing points and cable entry hole allowing direct mounting of the handset cradle bracket to it POLOswitch This dual function relay card connects to t...

Страница 6: ... adapter that plugs conveniently into the cradle of any one of the handsets in the system Terminals are provided on the cradle electronic module to terminate a 14V DC supply should the supply being used not have a jack compatible with the socket on the cradle If the bus voltage between terminals 1 and 2 is lower than 8V DC power needs to be applied at another unit in the system The two wire bus of...

Страница 7: ... COM Lock Power supply Entry panel NO 2 1 COM How to prevent a would be intruder from tampering with the wires between the entry panel and gate motor in order to trigger the gate Option 1 Recommended solution Option 2 Cheaper solution CLOSE RELAY 2 B Trig Ring 1 3C V3 0 A 1 1 2 2 NO NO Com Com POLOswitch Benefit Two Wire bus with secure signal to operate gate Benefit Connect power to the POLOphone...

Страница 8: ... provided in the mounting holes adjust the base to be perfectly vertical B Ensure that sealing washer is fitted and closes off the mounting hole to prevent water ingress Page 8 POLOphone Intercom Entry panel installation Position entry panel on wall adjacent to entrance gate or door Mount at a height that allows for comfortably speaking into the microphone A recommended height is shown Lift off th...

Страница 9: ...route the cable into the unit from underneath as shown and terminate onto the electronics Refer to the wiring diagram See page 12 Write call button labels insert into lens es and clip lens es back onto chassis Clip outer cover back into position NB It will be necessary when commissioning the unit to have Secure the cover using the fixing screw provided in kit POLOphone Intercom Page 9 Entry panel ...

Страница 10: ...ndset Installation Handset Installation 1550mm 1 2 3 Position handset on wall where required and at a height that will allow for comfortable use of the handset A height of 1550mm from the floor to the base of the cradle is recom mended To remove the cradle base squeeze the sides of the cradle Extract the cradle base In the case of an uneven wall the tabs may be cut as shown to allow the cradle bas...

Страница 11: ... Clip the A long tail end of the telephone cord into the jack provided at the bottom of the cradle and similarly into the handpiece Replace the handpiece onto the cradle POLOphone Intercom Page 11 Handset installation 80mm 9 Tighten cable tie ensuring that there is sufficient slack to terminate the cable onto the electronics 80mm A B Terminate onto the electronics Refer to the wiring diagram See p...

Страница 12: ...m 2 Power can be connected to any component in the system 3 The diagram shows the 12V Battery Supply of gate motor connected to the entry panel to power the system 4 If power is being connected to the handset use either a mains adapter with a DC jack compatible with the socket provided A or connect 12 14V DC to the terminals B 5 If the bus voltage between terminals 1 and 2 is lower than 8V DC powe...

Страница 13: ...le level occurs just before the entry panel howls POLOphone Intercom Page 13 Wiring group volume settings Group Volume Settings Group Volume Settings Group Volume Settings Wiring diagram for poloswitch Two wire bus with secure signal to operate gate Connect power to the POLOphone via the POLOswitch There is no need to take battery power to the entry panel An alternative solution is to wire TRG and...

Страница 14: ...button rings both groups of handsets Or Press the bottom button two beeps will be heard to set the entry panel as a two button unit where the top button rings group A handsets and the bottom button rings group B handsets On power up the entry panel will beep either once or twice to indicate the configuration selected one beep for a one button and two beeps for a two button entry panel Handset call...

Страница 15: ...voltage at Entry Panel Check polarity of two wire bus Check two wire bus voltage at Handset Check coil cord connection Check that correct group A or B is selected on Handset Increase volume on Handset Check coil cord connection to cradle Check hook switch is free to move Fault finding guide At each handset press the pushbutton to call the handsets in the other group Make sure that these handsets r...

Страница 16: ...22072013 Sharecall 0860 CENTURION 0860 236 887 Head Office 27 11 699 2400 Sharecall Technical Support 0861 003 123 or 27 11 699 2481 from 07h00 to 18h00 GMT 2 Sharecall numbers applicable when dialed from within South Africa only ...

Отзывы: