background image

1. Programming the G-SWITCH-22

Special Functionality

The 

G-SWITCH-22

 offers various advanced and useful features which can 

be easily set up via SMS or using the 

G-WEB

 online user interface. 

These features are intended to enhance the Module’s capabilities and offer 
the user more flexibility in applying the Module as a full monitoring and 
control solution.

Below appears a list of the 

G-SWITCH’s

 advanced features as well as a 

definition of each.

&

Sticky Latches: 

The Module’s Outputs can be configured to 
‘remember’ their state between power cycles. 
For instance, if Output 2 was active, i.e. the relay 
in an energised state, and the power is removed, 
when power is reapplied Output 2 will return to the 
activated state. This functionality is referred to as a 
‘sticky latch’ and can be enabled or disabled. 
Sticky latches don’t apply to pulsed Outputs and 
are enabled by default

&

Filter Time: 

Filter Time determines how long an Input event 
(rising or falling edge) must be present before it is 
recognised, i.e. an SMS is sent. The time is set in 
increments of one second and the default is 0 

&

Blanking Time: 

Blanking Time determines how long the unit will 
wait between events before it will recognise the 
next event

&

Event Count: 

This refers to how many Input events must occur 
before it is recognised and an SMS notification is 
sent to users

&

All Pass Mode: 

  When enabled, this useful mode allows any number 

that gives the Module a Missed Call to activate the 
Outputs, irrespective of whether they are learned 
into memory. A typical application would be an 
event such as a wedding where many guests need 
to be given temporary access. Instead of manually 
learning in a 100 guests and then having to delete 
them again after the occasion, the administrator 
can simply enable All Pass Mode and disable it 
again afterwards

&

Permitted    

The G-SWITCH-22 allows for time-periods to be

 

Access Mode 

specified during which a specific user's phone 

 

(Recurring

 

number will be valid and will be allowed to activate 

 

Weekly)

  

the unit's outputs via

 

Missed Call or SMS. 

  

 

Any activation from the user initiated outside of the 

  

 

specified time-period will be ignored.

  

 

For instance, a user can be granted access between 

  

 

8:00 and 17:00, Monday to Friday and his access 

  

 

barred from activating the outputs after hours and 

  

 

during weekends

&

Permitted  

In this mode, an administrator can specify two

 

Access Mode  

time-based parameters between which a number

 

(Once off)

  

will be valid. This is ideal for guesthouse and Bed

 

 

 

and Breakfast owners, as it enables them to set 
specific arrival and departure dates and times and 
allow access to guests based on these 
time-dependent limits. This feature and only be 
activated via G-Web

Multi-user Capability (1200 phone numbers)

It is important to note that the memory of the 

G-SWITCH-22

 2G GSM 

Module is limited to 1200 authorised phone numbers. In other words, a 
maximum of 1200 phone numbers can be registered on the system at any 
one time. Each phone number can be configured uniquely with respect to 
Inputs and Outputs, as well as activation and notification messages. Each 
phone number can also be assigned a limited number of uses for each 
Output.

When the memory limit is reached, trying to add new phone numbers will 
not overwrite or affect the existing numbers stored into the system, it will 
just not be possible to add the additional numbers.

3. Command Structure

Programming commands are sent to the Module using a standard text 
message (SMS).

The command structure must always take the following form: 

p.xxxx.command1.parameter1.parameter2 command2.
parameter1.parameter2

, etc.

2. In a Hurry?

To simply add a phone number to the Module to trigger Output 1, with 
the default pulse time activated through a Missed Call, send the following 
SMS to the Module: 

p.xxxx.ap.yyyyyyyyyy

,

 

where 

xxxx

 is the system 

password (default is 1234

¹

), and 

yyyyyyyyyy

 is the phone number you 

wish to add.

1. For your own security, it is recommended that the default password 

be changed and that the SIM PIN code protection is enabled once 
the unit has been configured.
(see 

CO

. ‘Configuring the Module’)

Record system password here

Record new SIM PIN here

Ensure that a record of your system password is kept in a safe place.

Ensure that a record of the new SIM PIN number is kept in a safe place. 

Содержание G-SWITCH-22

Страница 1: ...Centurion Systems Pty Ltd www CentSys com G SWITCH 22 2G GSM Module Programming Guide TM...

Страница 2: ...or SMS Any activation from the user initiated outside of the specified time period will be ignored For instance a user can be granted access between 8 00 and 17 00 Monday to Friday and his access barr...

Страница 3: ...eletes Output 2 IN1 Activates Input 1 DIN1 Deletes Input 1 IN2 Activates Input 2 DIN2 Deletes Input 2 DIN1S Deletes Input 1 string DIN2S Deletes Input 2 string DOU1S Deletes Output 1 string DOU2S Dele...

Страница 4: ...means of the following command structure p xxxx AP phone number OUz y INz y In this instance xxxx again represents the password z is the number of the Input Output to which one wishes to assign a tex...

Страница 5: ...the following command p xxxx co lm where xxxx represents the system password p xxxx AP 0823359981 OU2 10 IN1R 3 IN1F 4 Adds phone number 0823359981 to the system and configures Output 2 to be activate...

Страница 6: ...Deletes phone numbers 0841234567 0837654321 and 0827766554 from the system Description Parameters Phone number s up to 19 digits Delete Phone from the system DP DP Deleting a Phone This command allows...

Страница 7: ...system Command Description p xxxx CO CS yyyy Change the SIM card PIN code yyyy is the NEW PIN code p xxxx CO EP Enable checking of the SIM PIN number on startup p xxxx CO DP Disable checking of the SI...

Страница 8: ...e of the commands below OU OU1on Output command Output 1 on OU OU2on Output command Output 2 on OU OU1off Output command Output 1 off OU OU2off Output command Output 2 off OU OU1on2off Output command...

Страница 9: ...phone number will activate Output 1 The incoming please call me SMS must contain the Please call text in order to trigger output 1 p xxxx CO PCMS call 0811234678 Configures the Module so that a Please...

Страница 10: ...ems Pty Ltd reserves the right to change any product without prior notice All product and brand names in this document that are accompanied by the symbol are registered trademarks in South Africa and...

Отзывы: