2-3-3
U29P2HSMA
1-A. Preliminary/Final Checking and
Alignment of Tape Path
Purpose:
To make sure that the tape path is well stabilized.
Symptom of Misalignment:
If the tape path is unstable, the tape will be damaged.
Note:
Do not use an Alignment Tape for this proce-
dure. If the unit is not correctly aligned, the tape may
be damaged.
1. Playback a blank cassette tape and check to see
that the tape runs without creasing at Guide Rollers
[2] and [3], and at points A and B on the lead sur-
face. (Refer to Fig. M3 and M4.)
2. If creasing is apparent, align the height of the guide
rollers by turning the top of Guide Rollers [2] and
[3] with a Guide Roller Adj. Screwdriver. (Refer to
Fig. M3 and M5.)
3. Check to see that the tape runs without creasing at
Take-up Guide Post [4] or without snaking between
Guide Roller [3] and ACE Head. (Fig. M3 and M5)
4. If creasing or snaking is apparent, adjust the Tilt
Adj. Screw of the ACE Head. (Fig. M6)
1-B. X Value Alignment
Purpose:
To obtain maximum PB FM envelope signal at the pre-
set position of the Tracking Control Circuit, align the
Horizontal Position of the ACE Head.
Symptom of Misalignment:
If the Horizontal Position of the ACE Head is not prop-
erly aligned, maximum PB FM envelope cannot be
obtained at the preset position of the Tracking Control
Circuit.
1. Connect the oscilloscope to TP301 (C-PB) and
TP501 (CTL) on the Main CBA. Use TP502 (RF-
SW) as a trigger.
2. Playback the Gray Scale of the Alignment Tape
(FL6N8) and confirm that the PB FM signal is
present.
3. Set the Tracking Control Circuit to the preset posi-
tion by pressing CH UP button on the remote con-
trol unit then “PLAY” button on the unit. (Refer to
note on bottom of page 2-3-4.)
4. Use the Flat Screwdriver so that the PB FM signal
at TP301 (C-PB) is maximum. (Fig. M6)
Guide Roller [2]
Guide Roller [3]
A
B
Take-up Guide Post [4]
ACE Head
Fig. M3
Lead Surface of Cylinder
Tape
Fig. M4
Take-up Guide
Post
Tape
Guide Roller
Tape
Correct
Incorrect
Fig. M5
Azimuth Adj. Screw
Flat
Screwdriver
Tilt Adj. Screw
ACE Head
Fig. M6
Содержание GEB100
Страница 22: ...1 8 3 1 8 4 HG221SCM1 Main 1 5 Schematic Diagram...
Страница 23: ...Main 2 5 Sensor Schematic Diagrams 1 8 5 1 8 6 HG221SCM2...
Страница 24: ...Main 3 5 Schematic Diagram 1 8 7 1 8 8 HG221SCM3...
Страница 25: ...Main 4 5 Jack Schematic Diagrams 1 8 9 1 8 10 HG221SCM4...
Страница 29: ...1 8 17 1 8 18 Jack CBA Top View Jack CBA Bottom View BHG470F01014C...
Страница 35: ...1 13 1 HG221FEX EXPLODED VIEWS Front Panel A1X...
Страница 37: ...1 13 3 HG221PEX Packing Some Ref Numbers are not in sequence X2 X3 X20C X20B X20A X1 X4 S1 Unit S3 A14 S2 S2...
Страница 69: ...GEB100 HG221ED 2004 04 15...