Central Pneumatic 98635 Скачать руководство пользователя страница 8

SKU 98635 

For technical questions, please call 1-800-444-3353. 

Page 8

Observe the level of oil through the 

3. 

Oil Sight Glass (23).  The oil level 

should appear between the “MINI-

MUM” and “MAXIMUM” marks on the 

Sight Glass. 

(See Figure A.)

Add compressor oil into the Breather 

4. 

(26), while checking the Oil Sight 

Glass (23), until the oil level reaches 

the “MAXIMUM” mark on the Sight 

Glass.  Do not exceed the “MAXI-

MUM” mark on the Sight Glass. 

(See Figure A.)

When finished topping off the oil, re-

5. 

install the Breather (26). 

(See Figure A.)

BREAtHER

(26)

OIL SIGHt GLASS

(23)

FIGuRE A

Incorporate an in-line oiler, shut-off 

6. 

valve, regulator with pressure gauge, 

and filter for best service, as shown in 

the diagram on the next page. 

 An in-

line shutoff valve is an important 

safety device because it controls 

the air supply even if the air hose 

is ruptured.  (See Figure B.)

tool

Air 

Compressor

Quick 

Coupler

Air Hose 

on Reel

Filter

Regulator with 

Pressure Gauge

Male 

Connector

Male 

Connector

Valve

Quick 

Coupler

Attach an air hose to the Compres-

7. 

sor’s Quick Coupling (63).  Then con-

nect the other end of the air hose to 

the air inlet of the pneumatic tool.  
Close the in-line safety valve be-

8. 

tween the Compressor and the tool.
Turn on the Compressor according 

9. 

to the directions in this manual and 

allow it to build up pressure until it 

cycles off at 115 PSI.
Adjust the Compressor’s Tool Pres-

10. 

sure Gauge (64) so that the air output 

is enough to properly power the tool, 

but the output will not exceed the 

tool’s maximum air pressure at any 

time.  Adjust the pressure gradually, 

not to exceed the maximum working 

pressure.
Inspect the air connections for leaks.  

11. 

Repair any leaks found.
If the tool will not be used at this 

12. 

time, turn off and detach the air sup-

ply, safely discharge any residual 

air pressure, and release the tool’s 

throttle and/or turn the switch to its off 

FIGuRE B

Содержание 98635

Страница 1: ...served No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not...

Страница 2: ...us situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address...

Страница 3: ...off po sition before connecting to power source picking up or carrying the tool Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents...

Страница 4: ...to an electrical outlet Turn off the Com pressor and unplug it from its electri cal outlet before leaving This product is not a toy Keep it out 4 of reach of children People with pacemakers should 5 c...

Страница 5: ...d result Any tube pipe or hose used must have a pressure rating higher than 150 PSI Minimum recommended pipe size Up to 50 feet long use 1 2 diameter Greater than 50 feet use 3 4 diam eter Larger diam...

Страница 6: ...d have a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resi...

Страница 7: ...PSI Crankcase Oil Type SAE30 or L DAB 100 over 50 F SAE10 or L DAB 68 under 50 F Oil Capacity 8 5 ounces Unpacking When unpacking check to make sure that the item is intact and undamaged If any parts...

Страница 8: ...ee Figure B Tool Air Compressor Quick Coupler Air Hose on Reel Filter Regulator with Pressure Gauge Male Connector Male Connector Valve Quick Coupler Attach an air hose to the Compres 7 sor s Quick Co...

Страница 9: ...procedures Work Piece and Work Area Set Up Designate a work area that is clean 1 and well lit The work area must not allow access by children or pets to prevent injury and distraction Route the Power...

Страница 10: ...aches the pneu 7 matic tool observe the Tool Pressure Gauge 64 Adjust the Regulator 62 to feed the proper PSI to the tool To do so turn the Regulator clockwise to increase PSI to the tool Turn the Reg...

Страница 11: ...n two turns Then retighten the Drain Valve See Figure C Squeeze the trigger on the pneumatic 13 tool to release any remaining air pres sure from the tool Then disconnect the air hose from the tool and...

Страница 12: ...Carefully unscrew no more than two turns the Drain Valve 53 until the compressed air and moisture begins to be discharged from the Tank Allow sufficient time for all of the air and moisture to escape...

Страница 13: ...SKU 98635 For technical questions please call 1 800 444 3353 Page 13 Power switch will not turn off Compressor 1 Defective power switch power switch...

Страница 14: ...sher 5 47 Connecting Rod 14 Motor Stator 48 Capacitor 15 Motor Rotor 49 Wheel Assembly 16 Bearing 6203 50 Wheel Shaft Screw 17 Oil Seal 51 Wheel Shaft Sleeve 18 Crankcase 52 Hex Nut M8 19 Crank 53 Dra...

Страница 15: ...SKU 98635 For technical questions please call 1 800 444 3353 Page 15 ASSEMBLY DIAGRAM...

Страница 16: ...of incidental or consequential damages so the above limita tion of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties...

Отзывы: