Central Pneumatic 95658 Скачать руководство пользователя страница 8

OPERATING THE FLOOR NAILER

2.  Attach the Floor Nailer to the air supply at the Quick Connector.  Start your    

 

 

compressor and check the pressure, making sure it is set at the recommended

 

70-90 PSI

.  

Do not exceed the maximum 90 PSI.

3. 

      WARNING!  

Keep your feet clear of the Floor Nailer.

NOTE:  

Before using on a floor, test the tool on a scrap piece of wood.  Adjust  

 

 

the driving depth by providing more or less air pressure.  Never exceed 90 PSI.

5.  Hold the Arm (56) securely and press the Spacer (32) to the work surface,    

 

 

making sure the Spacer is over the nail/staple target position.

6.  Press down hard so that the Spacer (32) is firmly contacting the work surface.   

 

 

Then, using the Hammer (57), strike the Hammer Face (10) firmly to drive the  

 

 

fastener into the work surface.  Lift the Floor Nailer off the work surface.  Repeat    

 

this process until the job is completed.

7.  When finished, disconnect the Floor Nailer from the air supply source.

8. 

 

WARNING!  

After disconnecting the Floor Nailer from the air compressor,   

 

 

there could still be enough air pressure to fire the Floor Nailer.  After the    

 

 

air hose is disconnected, always fire the Floor Nailer into scrap wood  

 

 

 

repeatedly to make sure all of the compressed air is expended.

9.  When finished, make sure to store the Floor Nailer in a clean, dry, safe location  

 

 

out of reach of children and other unauthorized people.

1. 

WARNING!  This tool DOES NOT use a SAFETY MECHANISM.  

  

 

 

Extreme caution must be used whenever this tool is connected to an air    

 

supply.  If the tool is dropped, or if the Hammer Face (10) is accidentally    

 

struck, then the tool will fire a nail or staple, potentially causing 

SEVERE    

 

PERSONAL INJURY.

HAMMER

(57)

SPACER

(32)

HAMMER FACE

(10)

WORK SURFACE

ARM

(56)

SKU   97586

 

95658  

      

For technical questions, please call 1-800-444-3353  

        PAGE 8

Содержание 95658

Страница 1: ...Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyright 2007 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools...

Страница 2: ...ions for which this tool was designed It will do the job better and more safely at the rate for which it was intended Do not modify this tool and do not use this tool for a purpose for which it was not intended SAVE THIS MANUAL WARNING When using tool basic safety precautions should always be followed to reduce the risk of personal injury and damage to equipment Read all instructions before using ...

Страница 3: ...nected altered or not working properly 10 Disconnect air hose and release any built up air pressure Never service the Floor Nailer clear jams or disassemble with the air hose attached Always release any built up air even after disconnecting hose Disconnect the Floor Nailer when not in use 11 Remove adjusting wrenches Check that adjusting wrenches are removed from the tool or machine work surface b...

Страница 4: ...his happens either use the compressor without an extension cord or find a larger amperage circuit to use 19 Maintenance The maintenance outlined in the Maintenance section should be performed regularly For your safety this product should be serviced or repaired regularly only by a qualified technician 20 Compressed air only Use clean dry regulated compressed air at between 70 and 90 PSI Never use ...

Страница 5: ... when moving the tool in the workplace Carry the tool by the handle to avoid contact with the trigger 29 Avoid working alone If an accident happens an assistant can bring help 30 Note Performance of the compressor if powered by line voltage may vary depending on variations in local line voltage Extension cord usage may also affect the tool performance 31 WARNING The warnings cautions and instructi...

Страница 6: ... ANSI approved impact safety goggles when reloading or performing any other maintenance on this tool Other people in the work area must also wear ANSI approved impact safety goggles SKU 97586 95658 For technical questions please call 1 800 444 3353 PAGE 6 To Attach A Quick Coupler 1 This tool comes with a 1 4 Quick Connector attached to the Air Plug 55 prior to operation You should also wrap the t...

Страница 7: ...agazine 50 from the side The head of the cleat nails should be inserted into the notch on the Fixed Magazine 50 Up to 100 cleat nails may be loaded in the Fixed Magazine 3 Push the Movable Magazine 35 forward and secure the Movable Magazine in place with the Lock 44 Loading Staples 1 Press the Lock 44 and pull the Movable Magazine 35 back 2 Place a full clip of the desired size staples 1 to 2 long...

Страница 8: ...ff the work surface Repeat this process until the job is completed 7 When finished disconnect the Floor Nailer from the air supply source 8 WARNING After disconnecting the Floor Nailer from the air compressor there could still be enough air pressure to fire the Floor Nailer After the air hose is disconnected always fire the Floor Nailer into scrap wood repeatedly to make sure all of the compressed...

Страница 9: ...e or repairs are done including clearing jams FIRST 1 Disconnect the Floor Nailer from its air supply 2 Empty the Moveable Magazine 35 completely and leave it open 3 Attempt to fire the Floor Nailer into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any nails staples Use eye and ear protection when clearing jams Always wear ANSI approved impact safety goggles a...

Страница 10: ...tion out of reach of children Anytime inspection maintenance and cleaning are done FIRST 1 Disconnect the Floor Nailer from its air supply 2 Empty the Moveable Magazine 35 completely 3 Attempt to fire the Floor Nailer into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any nails staples INSPECTION MAINTENANCE AND CLEANING 4 Inspect the air supply Screen that is ...

Страница 11: ...in Cylinder Cap 1 Loose nose Screw 13 2 Seal 17 is cracked or worn 1 Tighten and recheck 2 Replace Seal Lack of power Slow to cycle Low power when shooting and returning 1 Tool is too dry 2 Air pressure too low 3 Exhaust flocked 1 Add about 3 drops of pneumatic tool oil into the Air Plug 55 2 Check to make sure regulator on air compressor is set between 70 PSI and 90 PSI 3 Clean exhaust channel Sh...

Страница 12: ... 3 5 28 Shoe 48 Leaf Spring 9 Piston Assy 29 Joint Guide 49 Screw M3 x 8 10 Hammer Face 30 Bushing 50 Fixed Magazine 11 Screw M5 x 20 31 Screw M6 x 16 51 Spring Pin 2 5 x 10 12 Cylinder Cap 32 25 32 Spacer 52 Nut 13 Screw M4 x 20 33 Screw M6 x 12 53 Washer 14 Spring Washer 4 34 Spring Pin 2 x 14 54 Clamp Screw 15 Poppet Actuator 35 Movable Magazine 55 Air Plug 16 O Ring 54 2 x 3 5 36 Spring Washer...

Страница 13: ...d fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide y...