![Central Pneumatic 95658 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/central-pneumatic/95658/95658_assembly-and-operating-instructions-manual_2582310008.webp)
OPERATING THE FLOOR NAILER
2. Attach the Floor Nailer to the air supply at the Quick Connector. Start your
compressor and check the pressure, making sure it is set at the recommended
70-90 PSI
.
Do not exceed the maximum 90 PSI.
3.
WARNING!
Keep your feet clear of the Floor Nailer.
4
NOTE:
Before using on a floor, test the tool on a scrap piece of wood. Adjust
the driving depth by providing more or less air pressure. Never exceed 90 PSI.
5. Hold the Arm (56) securely and press the Spacer (32) to the work surface,
making sure the Spacer is over the nail/staple target position.
6. Press down hard so that the Spacer (32) is firmly contacting the work surface.
Then, using the Hammer (57), strike the Hammer Face (10) firmly to drive the
fastener into the work surface. Lift the Floor Nailer off the work surface. Repeat
this process until the job is completed.
7. When finished, disconnect the Floor Nailer from the air supply source.
8.
WARNING!
After disconnecting the Floor Nailer from the air compressor,
there could still be enough air pressure to fire the Floor Nailer. After the
air hose is disconnected, always fire the Floor Nailer into scrap wood
repeatedly to make sure all of the compressed air is expended.
9. When finished, make sure to store the Floor Nailer in a clean, dry, safe location
out of reach of children and other unauthorized people.
1.
WARNING! This tool DOES NOT use a SAFETY MECHANISM.
Extreme caution must be used whenever this tool is connected to an air
supply. If the tool is dropped, or if the Hammer Face (10) is accidentally
struck, then the tool will fire a nail or staple, potentially causing
SEVERE
PERSONAL INJURY.
HAMMER
(57)
SPACER
(32)
HAMMER FACE
(10)
WORK SURFACE
ARM
(56)
SKU 97586
95658
For technical questions, please call 1-800-444-3353
PAGE 8