recOmmended minimum wire
gauge FOr extenSiOn cOrdS*
(120/240 vOlt)
nameplate
ampereS
(at full load)
extenSiOn cOrd
lengtH
25’
50’
75’
100’
150’
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
table a
* based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
v~
Volts Alternating Current
a
Amperes
n0 xxxx/min.
No Load Revolutions per Minute
(RPM)
SpeciFicatiOnS
Electrical Requirements
110 V; 60 Hz
Motor
Single phase, 1/2
HP, with overload
protection.
Motor RPM’s
3450
Throat Depth
6-1/2”
Cutting Capacity:
Round Stock
Rectangular Stock
Round Stock
Rectangular Stock
5-5/16” @ 90°
5-7/8”x 5-1/2” @ 90°
3-1/2” @ 45°
3-15/16” x 3-1/2” @
45°
Table Pivot
0-60 Left tilt only
Blade Length
67-1/2”
Blade Tooth Per Inch
10 TPI
Blade Feet Per Minute
213 FPM
unpacking
When unpacking, check to make sure
that the item is intact and undamaged. If
any parts are missing or broken, please
call Harbor Freight Tools at the number
shown on the cover of this manual as soon
as possible.
inStructiOnS FOr
putting intO uSe
read the entire impOrtant
SaFetY inFOrmatiOn
section at the beginning of this
manual including all text under
subheadings therein before set
up or use of this product.
tO prevent
SeriOuS injurY
FrOm accidental
OperatiOn:
turn the power Switch of the
tool to its “OFF” position and
unplug the tool from its
electrical outlet before
assembling or making any
adjustments to the tool.
note:
For additional information regarding