10
10
MOOD 1818WP User Manual
Eng
Cable (EU)
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth must to be connected! Pay attention to the safety! Before taking into
operation for the first time, the installation has to be approved by an expert.
6.4. Dmx Connection
When use a DMX controller, please make sure that there is no interference
sources (e.g. intercom, high frequency radio waves and radiation source).
DMX machines are designed to receive data through a serial Daisy Chain. A Daisy
Chain connection is where the DATA OUT of one fixture connects to the DATA IN of
the next fixture. The order in which the machines are connected is not important
and has no effect on how a controller communicates to each of them. Use an order
that provides for the easiest and most direct cabling.
3-Pin XLR
Pin 1: GND
Pin 2: DMX -
Pin 3: DMX +
OUTPUT
INPUT
DMX use of 3-Pin XLR Connectors
DMX Termonator
Unit 1
Unit 2
Last Unit
DMX 512
Connect machines using shielded 2-conductor twisted pair cable with 3-pin XLR
male to female connectors. The shield connection is pin 1, while pin 2 is Data Nega-
tive (S-), and pin 3 is Data positive (S+).
CAUTION: Wires must not come into contact with each other; otherwise the fix
-
tures will not work at all, or will not work properly.
6.5. DMX Terminator
DMX is a resilient communication protocol, however errors still occasionally occur.
In order to prevent electrical noise from disturbing and corrupting the DMX control
signals, a good habit is to connect DMX output of last fixture in the chain to a DMX
terminator, especially over long signal cable runs.