Gateway Instruction Manual 

Page 9 

 

 

Warning

:  The cover must be closed, clasped, and screwed/fastened shut with the 

supplied screws/fastener to prevent access to live circuits. 
 

Avertissement

: La couverture doit être fermée, fermée et serrée et a vissé/attaché 

fermé avec les vis/attachefournies pour prévenir l'accès pour vivre des circuits. 

3.5 Setup 

Prior to applying power, the Gateway must be added to the Data Center (including 
adding the Gateway and Monitor serial numbers into the database). 

3.5.1 

Cellular Gateway Setup 

There are no extra cables for the Cell Gateway. 
 
If your cellular modem was not factory provisioned or activated on a network then 
follow the special instructions located in the appendix under Advanced Setup. 

3.5.2 

Ethernet Gateway Setup 

Using an Ethernet cable, connect the Controller to a port on a network switch or 
hub or any standard RJ-45 network jack where a computer could gain access to the 
Internet. Longer Ethernet cables may be used, if necessary, but the total cable 
length includingpermanent wiring inside the building should not exceed 300 feet. 
The Gateway will connect only to the Data Center and no inbound port forwarding 
rules should be required on the customer’s network firewall.

 

 

If the local network requires a static IP address,then follow the special instructions 
located in the appendix under Advanced Setup

.

 

3.6 Activation 

Following wiring and setting up the Gateway, the unit can be activated by turning on 
the supply power.  When power is applied, the Gateway will enter a short test mode 
and the two lights on the front of the housing will cycle from off to the color Yellow.  
The Gateway will then enter an initialization phase, which may take several 
minutes, during which time

Data Center

 light will blink Yellow or Green.  Once the 

Gateway has communicated with the Data Center, it will enter normal operating 
mode and the 

Data Center

 light will turn solid Green. The status indicator lights can 

be interpreted as follows: 

Caution

: Risk of Explosion if battery is replaced by 

an incorrect type.Dispose of used batteries 
according to the instructions. 
 

Prudence

: Le Risque d'Explosion si la batterie est 

remplacée par un type incorrect. Débarrassez-vous 
des batteries utilisées selon les instructions. 

Gateway Instruction Manual 

Page 10 

 

The 

Data Center

 light indicates Data Center communication status.  The 

Data 

Center

 light blinks approximately once per second any time Gateway is 

powered. 

 

Blinking Red – Network connection failure. (No network connection or 
Loss of connection). 

 

Blinking Yellow – System is connected to the network, but is waiting for a 
response from network router or ISP. (Waiting for network) 

 

Solid Yellow - System is starting up or connecting to the network. (Network 
not ready) 

 

Blinking Green – Connected to the network, but the Data Center has not 
responded. (Waiting for Data Center to reply) 

 

Solid Green – Connected to the network and talking to the Data Center. 
(Normal operation) 

The 

MONITOR

 light provides information about radio communication between 

the Monitor and Gateway.  The 

MONITOR

 light is normally “off”.  It blinks only 

when the Gateway is receiving radio transmissions. 

 

 

Blinking Green – Data received from a valid Monitor. 

 

Blinking Yellow – Some data was received from a valid Monitor but the 
signal was weak or partially corrupt. 

Move the Gateway or Monitor and 

retest until the Monitor light blinks green.

 

 

Blinking Red – Radio signals were received from an invalid source. 

Service and Technical Support 

If you experience trouble with this equipment, please contact your distributor. 
 
 

CAUTION

: The manufacturer does not support field changes or modifications to 

any of the Level Monitoring System equipment unless they are specifically covered 
in this manual.  Any other modification to the equipment will void the manufacturer’s 
warranty. 
 

PRUDENCE

: Le fabricant ne soutient des changements de terrain ou des 

modifications à aucun des équipements de Système de surveillance de Niveau à 
moins qu'ils ne soient spécifiquement couverts dans ce manuel. Autre modification 
à l'équipement va le vide la garantie du fabricant. 
 
 

Warning

: This unit is to be serviced by qualified service personnel only. 

 

Avertissement

: Cette unité doit être assurée l'entretien par le personnel de service 

qualifié seulement. 
 
 
 

 

Содержание CGW Series

Страница 1: ...dental or consequential damages in connection with the furnishing performance or use of this material The manufacturer assumes no responsibility for the use or reliability of its products or equipment other than that for which it is intended or for use other than in the manner prescribed herein This document is protected by copyright All rights reserved No part of this document may be reproduced c...

Страница 2: ...onnected equipment This means that the Gateway should be fastened to a support and electrically connected to its supply by a permanent connection 2 Product Overview 2 1 Description The Gateway consists of a transceiver that collects Monitor information and either a cellular modem or Ethernet port that relays this information to a centralized data collector 2 2 Operation The Gateway can receive Rad...

Страница 3: ...ignals and cause an RF shadow which may prevent radio signals from reaching the Gateway Objects which are not electrically conductive such as wooden or fiberglass buildings non reinforced masonry trees plastic and glass have less effect on radio signals than metal objects Windows and wooden doors can provide radio signals access to otherwise closed metal buildings However low E window glass may ha...

Страница 4: ...pment is considered Class 1 which uses a protective earth ground Verify that the cables from the cover to the printed circuit board are properly connected Close the cover and secure the two latches Fuses F1 and F2 are permanently soldered on the PCB They are installed only for catastrophic failure and are not considered serviceable by an end user The connections for this power are located as follo...

Страница 5: ...an incorrect type Dispose of used batteries according to the instructions Prudence Le Risque d Explosion si la batterie est remplacée par un type incorrect Débarrassez vous des batteries utilisées selon les instructions Gateway Instruction Manual Page 10 The Data Center light indicates Data Center communication status The Data Center light blinks approximately once per second any time Gateway is p...

Страница 6: ...e All commands are typed in and pressing enter executes the command 5 2 Gateway Admin Console Application To access the administrator console application type the following on the command line gwadmin option parameters The command line is case sensitive and spaces separate the option and its parameter s The following is the list of available options Gateway Instruction Manual Page 12 Option case s...

Страница 7: ...nd can be confirmed byobserving the Data Center light as it transitions from red to yellow and then to flashing green as it waits for communication from the Data Center To return to the default setup of using a DHCP server for assigning the IP address enter the following command gwadmin setstaticip 0 1 Enable Static IP Addressing 0 Enable DHCP IP addressing setstaticip EnableStaticIP Enable Disabl...

Отзывы: