Data Logger  Instruction Manual 

 

 

2

 

III. Symbol Definition and Button Location:

 

 

: This indicates that the minus temperature is sensed.

 

℃℉

 

: Centigrade and Fahrenheit indication.

 

: Thermocouple Type Indication

 

MAX 

: The Maximum value is now being displayed

 

MIN 

: The Minimum value is now being displayed         

 

: This indicates auto power off is enabled.

 

 

: This indicates that the display data is being held. 

m-d 

: it indicates the value below is month and day 

h:m 

: it indicates the value below is hour and minute

 

m:s 

: it indicates the value below is minute and second

 

: it indicates year is displayed in the main window.

 

 

: The Battery is not sufficient for proper operation.

 

REC

 

: This indicates that the tester is recording. If it blinks, it indicates the memory is full.

 

             
 

 

Button Location: 

1

  K type temperature sensor T1 input 

connector 

2

  K type temperature sensor T2 input 

LCD display 

3

 ON/OFF button  

4

 Time display button  

5

 Record button 

6

  MAX MIN function control button   

7

 HOLD button 

8

  °C, °F control button 

9

  Offset calibration screw 

10

  Digital output connector 

11

  AC power adapter connector 

12

 Tripod connector 

13

  Battery cabinet cover 

 
 
 
 

POWER-UP  OPTIONS

REC

328

200

RANGE:

F

2498

C

1370

F

C

3

4

8

7

10

O

U

T

P

U

T

D

C

9

V

OPEN

C

A

L

9V  BATTERY

PLEASE  READ 

NEDA  1604  6F22  006P

MANUAL  FOR  SAFETY

9

5

HOLD

INTV

C

REC

CLOCK

TIME

SETUP

F

T1

T2

1

T1

T2

2

6

Содержание 306

Страница 1: ...T1 T2 REC POWER UP OPTIONS RANGE 200 C HOLD TIME SETUP CLOCK REC INTV C F 328 F 1370 C 2498 F 306 Datalogger SE 305 ...

Страница 2: ...tion the Thermocouples 3 4 3 Selecting the Temperature Scale 3 4 4 Data Hold Operation 3 4 5 DataLogger 3 4 6 Clock Setup 3 4 7 Recording Interval Setup 4 4 8 Time Operation 4 4 9 MAX MIN Operation 4 4 10 Auto Power Off 4 4 11 Low Battery Condition 4 4 12 Calibration Point 4 4 13 Digital Output 5 V Setup SE305 Thermo DataLogger RS232 interface software 7 ...

Страница 3: ...eading 1 C 200 C 400 C 0 5 reading 1 C 400 C 1370 C 0 2 reading 1 C 328 F 200 F 0 5 reading 2 F 200 F 200 F 0 2 reading 2 F 200 F 2498 F 0 3 reading 2 F Note The basic accuracy Specification does not include the error of the probe Please refer to the probe accuracy specification for additional details Sample Rate 1 25 times per second Dimension 184 64 30mm Weight 210g Approx Accessory K Type Bead ...

Страница 4: ... year is displayed in the main window The Battery is not sufficient for proper operation REC This indicates that the tester is recording If it blinks it indicates the memory is full Button Location 1 K type temperature sensor T1 input connector 2 K type temperature sensor T2 input LCD display 3 ON OFF button 4 Time display button 5 Record button 6 MAX MIN function control button 7 HOLD button 8 C ...

Страница 5: ... is no longer needed one may release the data hold operation by pressing HOLD button again When the meter is under Data Hold operation the TIME MAX MIN and C F button are disabled when you press TIME C F and max min button in HOLD mode there will be two continuous beeps To exit the MAX MIN mode one may press and hold MAX MIN button for two seconds 4 5 DataLogger When one presses the REC button the...

Страница 6: ...ain MAX and MIN will blink together This means that all these data is updated in the memory and the reading is the present temperature One may press MAX MIN to circulate the display mode among these options When the meter is under MAX MIN operation and C F button are disabled when you press C F button in MAX MIN mode there will be two continuous beep To exit the MAX MIN mode one may press and hold...

Страница 7: ...will return 3 0 6 ASCII 13 Command U Return 32768 bytes Command P Instead of returning all 32768 bytes it only return recorded data Command H Equivalent to one pushing on the HOLD button and no message is returned Command M Equivalent to one pushing on the MAX MIN button and no message is returned Command N Equivalent to one pushing and hold the MAX MIN button for two seconds to exit MAX MIN mode ...

Страница 8: ...E first two BCD code of T1 value 5th BYTE last two BCD code of T1 value 6th BYTE If bit3 of 2nd BYTE 0 first two BCD code of T1 T2 value If bit3 of 2nd BYTE 1 two BCD code of month 7th BYTE If bit3 of 2nd BYTE 0 last two BCD code of T1 T2 value If bit3 of 2nd BYTE 1 two BCD code of day 8th BYTE If bit3 of 2nd BYTE 0 first two BCD code of T2 value If bit3 of 2nd BYTE 1 two BCD code of hour 9th BYTE...

Страница 9: ...rt the SE305 CD ROM into your CD drive The SE305 installer should start automatically If it does not you can start it by running SETUP EXE from the root drive of the CD ROM 3 When installation is complete it will copy SE305 exe executable file and help file to your hard disk default is c program files SE305 4 For other operation instruction please refer to the on line help while executing SE305 Ma...

Страница 10: ... present data Real Time Run Start collecting real time data Stop Stop collecting real time data DataLogger By opening the DataLogger Window the user can load recorded data of meter to PC in this window ComPort Select the port manually Option Range Change the Y axis extention Graph Customization Graph Customization For more operation instruction please refer to the online help while executing SE305...

Страница 11: ...4 F NO 415 Jung Jeng Rd 238 Shu Lin Chien Taipei Taiwan E Mail center centertek com http www centertek com 306 03 CENTER TECHNOLOGY CORP ...

Отзывы: