cable

Once the blades of the cutting head are around the cable to be cut, stabilise the head in position  
(e.g. by pressing the cutting head against the ground); when used in the “man-hole” we recommend 
the usage of 

SS-TCY support strap

 (Ref. to 

§ 6

) in order to support the head in the horizotal stable 

position.

cable

• Using a grounding wire with ball & socket termination

 Unscrew knob (2) from the grounding socket 

 (1). 

 

 Screw the grounding pin (15) tightly into the 

  socket (1) (1/2”-13 UNC thread).

  Fully unwind the grounding wire and connect 

  it by the clamps to the grounding pin (15) and 
  to the grounding system using  the clamps.

3.4)  Positioning the cutting head 

The cutting head must be manually positioned 
around the cable to be cut based on the diameter 
of the cable (Ref. to 

§ 1

). 

 

TC065Y-SC-KV and TC096Y-KV:

 insert the cable 

  between the blades, at the desired cutting point. 

  TC050Y-KV and TC085Y-KV: 

 release latch (5) to open the blades.

  Insert the cable, close the head and fully secure the latch (5).

  Ensure that the head is fully secured: partial closure may damage the head.

 

TC120Y-KV:

 Extract the locking pin (13) to open the blades. Insert the cable, close the head and 

  fully secure the locking pin (13).

  Ensure that the head is fully secured: partial closure may damage the head.

 

Make sure the blades are exactly positioned on the desired cutting point.

1

15 *

2

* pur

chase separat

ely

TC120Y-KV

TC085Y-KV

TC050Y-KV

5

Содержание TC050Y-KV

Страница 1: ...1 HYDRAULIC CABLE CUTTING SAFETY HEADS TC050Y KV TC065Y SC KV TC085Y KV TC096Y KV TC120Y KV ENGLISH OPERATION AND MAINTENANCE MANUAL 17 M 219 U...

Страница 2: ...ING SOCKET 7 UPPER BLADE 2 RIGHT BLADE 8 LEFT BLADE 3 GROUNDING KNOB 9 GRIP 4 HANDLE to be fitted 10 HANGING POINTS FOR SUPPORT STRAP 5 HEAD LATCH 11 MALE INSULATED QUICK COUPLER 6 LOWER BLADE 12 HAND...

Страница 3: ...3 TC120Y KV max cutting diameter 4 3 4 TC085Y KV max cutting diameter 3 3 8 TC096Y KV max cutting diameter 3 3 4 1 8 3 2 10 12 11 1 13 12 11 10 6 3 5 6 7 1 4 10 11 3 7...

Страница 4: ...s and gloves when operating these safety heads WARNING SYMBOLS Do not cut Steel Do not attempt to cut Steel ropes or Steel reinforced cables ACSR the heads are designed for cutting Copper or Aluminum...

Страница 5: ...e absence of voltage cannot be guaranteed Hydraulic cable cutting safety heads must be used only with insulated flexible hoses and hydraulic pumps containing insulating oil Insulating oil is a special...

Страница 6: ...the insulated flexible hose to the female coupler of the pump CLICK 3 3 Grounding the cutting head Safety cutting heads are provided with a grounding socket 1 To ground the cutting head proceed as fol...

Страница 7: ...using the clamps 3 4 Positioning the cutting head The cutting head must be manually positioned around the cable to be cut based on the diameter of the cable Ref to 1 TC065Y SC KV and TC096Y KV insert...

Страница 8: ...components from damage and for transportation to the work place Only remove a cable cutting head from its case at the work place TC065Y SC KVandTC085Y KV removethehandle 4 before storing the head in...

Страница 9: ...h of the strap by means of the buckle 16 sotosupporttheheadinhorizontal position 7 RETURN TO Cembre FOR OVERHAUL In the case of a breakdown contact our Area Agent who will advise you on the problem an...

Страница 10: ...10 inch mm 16 1 410 16 9 430 9 2 233 5 3 136 5 8 147 11 6 296 4 9 125 12 6 319 4 2 107 TC050Y KV TC065Y SC KV TC085Y KV...

Страница 11: ...11 21 1 536 14 6 397 5 3 134 5 5 139 9 5 242 7 2 184 inch mm TC096Y KV TC120Y KV...

Страница 12: ...3 01 60 49 29 10 CS 92014 91423 Morangis C dex E mail info cembre fr www cembre fr Cembre Espa a S L U Calle Verano 6 y 8 28850 Torrej n de Ardoz Madrid Espa a Tel 34 91 4852580 Fax 34 91 4852581 E ma...

Отзывы: