6
Hydraulic pumps manufactured by
Cembre S.p.A.
are developed for use with hydraulic heads.
According to this specific use, they do not need and are not equipped with an oil non-return safety
system.
For this reason, use in applications different from those intended (for example with hydraulic jacks,
lifting systems or similar) can be dangerous for the operator.
Cembre S.p.A.
does not accept any liability arising from the use of its hydraulics pumps for ap-
plications different from those listed in its catalogues or other documentation.
Do not use the pump for purposes other than those intended by
Cembre S.p.A.
The operator should concentrate on the work being performed and be careful to maintain a ba-
lanced working position.
Avoid dirty surfaces: dust and sand are a danger to any Electro-hydraulic equipment.
Protect the pump and accessories from rain and moisture. Water will damage the pump and battery.
Do not connect the hydraulic head directly to the pump quick coupler but always use the specific
flexible hose.
The pump contains special insulating oil which must not be polluted with any other types of oil.
Never connect to a pump hydraulic heads that still contain oil, namely with the ram not fully retracted;
excess oil could cause the pump to malfunction.
Before disconnecting the flexible hose, check that the ram of the head is completely retracted, in
order to ensure that a sufficient quantity of oil is available for subsequent operations.
The pump is unsuitable for continuous use and should be allowed to cool down following uninter-
rupted, successive crimping operations; for instance, having exhausted a fully charged battery in
one session, delay battery replacement for a few minutes.
WARNINGS