17
ENGLISH
4.7) Errors/Malfunctions
These appear on the display during operation, combined with a beep to notify the operator of
procedural or operational errors.
Message
Error description
S
olution
ERROR
Ï
Ð
In CRIMPING mode, oil discharge is
activated before waiting for the mo-
tor to be automatically switched off
.
Repeat the work cycle, keeping the start but-
ton pressed down until the motor switches off
automatically.
The pump has been started without
fl exible hose connected or the fl e-
xible hose is not correctly connected
Press the release button, connect the fl exible
hose or check the correct connection to the
pump.
001
Ï
Ð
Abnormal power consumption of
the motor.
The pump stops.
Wait for the display to turn off (60 sec.) or
remove and re-insert the battery, then re-start
the pump.
If the error occurs frequently, contact
Cembre
.
002
Ï
Ð
Output voltage of the pressure
transmitter is out of the pre-set
range.
The pump stops and doesn't re-start.
Remove and re-insert the battery, if the error
occurs, contact
Cembre
.
003
Ï
Ð
Failure to reach the set pressure
within 120 sec. of continuous opera-
tion of the pump.
Repeat the work cycle; if the error occurs fre-
quently, contact
Cembre
.
004
Ï
Ð
Overcharging of the battery with
protection tripping.
The pump stops.
Wait for the display to turn off (60 sec.) or
remove and re-insert the battery, then re-start
the pump.
If the error occurs frequently, contact
Cembre
.
Errors 00.. are displayed for about 30 seconds before being reset, but will display re peat-
edly in the event of permanent anomalies.
5. MAINTENANCE
The pump is robust, completely sealed, and requires very little daily maintenance. Compliance
with the following points, should help to maintain its optimum performance:
5.1) Thorough cleaning
Dust, sand and dirt are a danger for any hydraulic device.
Every day, after use, the pump and accessoires must be wiped with a clean cloth taking care to
remove any residue. Do not use Hydrocarbons to clean the rubber parts.
After use, protect the couplers of the pump, hose and hydraulic head with their protective
caps to prevent contamination.
Содержание B68M-P18
Страница 2: ...2 FIG BILD 2 CB PU FH SS RC BC RB RB FIG BILD 1 1 5 8 1 11 7 6 3 2 4 9 10 ...
Страница 3: ...3 FIG BILD 4 FIG BILD 3 18 5 4 8 20 21 22 22 22 7 ...
Страница 71: ...71 ...