16
ENGLISH
4.6) Alarms/Warning
These appear on the display during operation, inform the operator on the state of the pump.
Message
Meaning
Description
BATTERY
Ï
Ð
BATTERY
LOW
Replace or recharge the battery.
NOTE: when the battery voltage falls below a minimum safety
threshold,
the pump will not start
, although it is still possible
to end the work cycle in progress.
BATTERY
Ï Ð
BATTERY
TEMPERATURE
HIGH
Remove the battery and wait until it cools down.
In order to cool it quicker, it is possible to insert it into the sup-
plied battery charger supplied, thus making use of the specifi c
“AIR COOLED” function.
max 90°
90°
MOTOR-PUMP
TEMPERATURE
HIGH
The maximum permitted operating temperature of 90 °C (194
°F) is reached.
The pump stops
; in this instance wait for it to cool.
Only when the permitted working temperature is reached will
it be possible to re-use the pump.
INSUFFICIENT
OIL
This appears when the pressure of the hydraulic circuit doesn't
increase but remains near to zero for a duration of 30 consecu-
tive seconds.
Check the oil level and if necessary refi ll (Ref. to § 5.4).
30001
3
Ï
Ð
REQUEST
MAINTENANCE
No. of cycles to maintenance reached; the pump continues to
work however, it is recommended that it is sent to
Cembre
for
a complete overhaul (Ref. to § 6).
NOTE: this message, will reappear when the pump has been
idle for 30 s.