After each working cycle, and after the extraction of the battery from the tool, an integrated  

  

  battery 

cut-off  device will operate after 70 s approx. Then the LED nearest to button (P) will  

        fl ash 5 times each 14 s approx. The battery will be reactivated when it is reintroduced into 
        the tool and the operating button is pressed.

3.   MAINTENANCE

The tool is robust, completely sealed, and requires very little daily maintenance. Compliance with 
the following points, should help to maintain its optimum performance:

3.1) Thorough cleaning

  Dust, sand and dirt are a danger for any hydraulic device. Every day, after use, the tool must be 

  wiped with a clean cloth taking care to remove any residue, especially close to pivots and move-
 able 

parts.

  Do not use hydrocarbons to clean the rubber parts.

  Regularly lubricate the moving parts and pivot pins of the head with a few drops of oil.

3.2) Storage case

When not in use, the tool should be stored and transported in the plastic case, to prevent damage. 
The case, type VAL-P40, is suitable for storing the tool and accessories.
VAL-P40: Size 520x432x126 mm (20.5x17.0x5.0 inches). Weight 2,6 kg (5.7 lbs).

3.3) Routine maintenance 

When the tool reaches the predetermined number of hours worked, it will signal that routine 
maintenance is recommended.

  

The tool will continue to work however 15 sec. after use an alarm comprising 3 beeps combined

        with illumination of the worklights will signal that its return to 

Cembre

 for service is recom-

        mended (see § 7).

4.   BLADE  REPLACEMENT

  (Ref. to Fig. 5)

  

When changing blades, the battery must fi rst be removed from the tool.

After extended use, the blades may break or loose their cutting edge.
Replace the blades as follows:

 Lower blade

–  Release latch (4), and open the tool head completely.
–  Operate the tool to advance the lower blade (3) and remove the battery.
–  Eject two split pins (12) from the ram (13) to release the blade (3).
–  Remove the broken blade from the ram, insert the new blade and fi t with two split pins.

  

Before closing the tool head, push the release button (6) and fully retract the lower blade, 

        otherwise the tool head assembly may hit and damage, the lower blade.

 Upper blade

–  Release latch (4), and fully open the tool head.
–  Remove circlip (16) and extract the head pin (15) to release the latch.
–  Remove circlip (23) and latch pin (15) to release the latch.
–  Remove the latch and recover the latch spring (24).

Содержание B-TC250YA

Страница 1: ...1 BATTERY OPERATED HYDRAULIC CUTTING TOOL ENGLISH OPERATION AND MAINTENANCE MANUAL 17 M 211 U B TC250YA B TC250YNA...

Страница 2: ...2 4 1 1 Low battery 5 adhesive tape 14 19 2 17 18 15 4 16 24 3 12 13 23 22 21 5 FIG 2 FIG 3 FIG 4 FIG 5 4 7 Makita battery FIG 1b FIG 1a Metabo battery 7...

Страница 3: ...PPER BLADE 3 LOWER BLADE 4 LATCH 5 OPERATING BUTTON 6 PRESSURE RELEASE BUTTON 7 BATTERY RELEASE 8 BATTERY 9 RING FOR SHOULDER STRAP 10 BATTERY ADAPTER FIG 6 5 6 2 1 1 9 3 4 10 8 7 4 1 9 3 2 1 5 6 8 7...

Страница 4: ...glasses and gloves when operating this tool WARNING SYMBOLS User information applies in member states of the European Union Directives 2011 65 EU and 2012 19 EU page see page 9 Tool Battery Never thr...

Страница 5: ...ing Copper Aluminium ACSR and Steel conductors ropes and rods guy wire including EHS ground rod up to 5 8 Max cutting diameter mm inches 25 1 Operating pressure bar psi 880 12 700 Dimensions mm inches...

Страница 6: ...attery Electro hydraulic tools should not be operated in pouring rain 2 INSTRUCTIONS FOR USE The part reference includes the following Hydraulic cutting tool B TC250YNA is fitted with adapter to use M...

Страница 7: ...position it 2 4 Cutting Firmly hold the tool and operate the push button 5 to gradually move the lower blade 3 to cut through the conductor When the cut is performed release the push button 5 otherwis...

Страница 8: ...AL P40 Size 520x432x126 mm 20 5x17 0x5 0 inches Weight 2 6 kg 5 7 lbs 3 3 Routine maintenance When the tool reaches the predetermined number of hours worked it will signal that routine maintenance is...

Страница 9: ...computer it is necessary to remove CBA MTMK battery adapter Removethescrews Ref tofig 7and7a and slide the adapter out mini USB FIG 7a FIG 8 B TC250YNA USER INFORMATION in accordance with Directives...

Страница 10: ...x 2 1 10 5 mm 19 x 2 3 11 5 mm TENSILE STRENGTH Copper 25 25 Aluminium Almelec Copper Aluminium TYPICAL EXAMPLES ROPES CONDUCTORS RODS daN mm2 lbs sq in 59 450 29 000 49 300 261 000 13 16 20 23 25 43...

Страница 11: ...11...

Страница 12: ...22 Avenue Ferdinand de Lesseps 91420 Morangis France T l 01 60 49 11 90 Fax 01 60 49 29 10 CS 92014 91423 Morangis C dex E mail info cembre fr www cembre fr Cembre Espa a S L U Calle Verano 6 y 8 288...

Отзывы: