3.4. 

Other function 

3.4.1 

Backlight 

The scale have three backlight mode: on, off and auto.  

ON: backlight will turn on however current weight is zero or not Zero  
OFF: backlight will turn off however current weight is zero or not zero 
AUTO:  backlight  will  turn  on  when  current  weight  is  not  zero  and  it  will  turn  off  if  current  weight  is 

zero 
You can press B/L key to set backlight mode, display will show current backlight mode, press SAVE 
key to select backlight mode (ON/OFF/AUTO), after you select, press TARE key to sure. 
 

3.4.2 

Automatic unit price clear 

The  scale  can  set  automatic  unit  price  clear,  when  return  to  zero,  SPC  will  clear  the  unit  price 
automatically. 
Press  SAVE  key  will  turn  on  /  off  automatic  unit  price  clear  function,  when  SAVE  indicator  on, 
automatic unit price clear disable, when SAVE indicator off, automatic unit price clear enable. 

 

SETTING OF PARAMETERS  

4.1. 

ENTER SETTING MODE 

To set the parameters it is necessary to enter a secure menu.  This is done by entering a password number 
when requested. 
To  enter  the  parameter  menus  press  the  TARE  key  during  the  initial  counting  of  the  display  after  power 
turned on.  The Weight Display will show "

P n

  " requesting the password number to be entered. 

Press the "O" key four times.  The display will show "Pn- - - -", Press the TARE key.   
The  Parameter  menu  has  16  functions  that  can  be  accessed  using  the  SAVE  key  to  cycle  through  the 
choices.  The Weight Display will show the name of the functions. Also you can press 0 to select F0, and key 
2  to  select  F2……  To  enter  a  function  press  the  TARE  key. At  any  time  press  the  ZERO  key  to  return  to 
weighing.  

Содержание SPC-S

Страница 1: ...SPC SERIES Ref 49 MCESPCEN03 Rev 03 User s Manual...

Страница 2: ......

Страница 3: ...RATION 3 3 2 1 Zero the scale 3 3 2 2 Tare 3 3 2 3 Overload Warning 3 3 2 4 Unit price setting 3 3 2 5 Change unit 3 3 3 UNIT PRICE MEMORY 3 3 3 1 Save the unit price 3 3 3 2 Load the unit price 3 3 4...

Страница 4: ......

Страница 5: ...contain minerals that will corrode electronic circuits Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water If scale meet water...

Страница 6: ...set the backlight mode ON OFF AUTO ACCOUNT The ACCOUNT key is used to do memory recall give change and memory clear in one time M The M key adds data to the accumulators If the weight is less than 20d...

Страница 7: ...3 Overload Warning Please do not add item that is over the maximum capacity When reading OL and hear beeping sound remove the item on the platter to avoid damage to the load cell 3 2 4 Unit price set...

Страница 8: ...off automatic unit price clear function when SAVE indicator on automatic unit price clear disable when SAVE indicator off automatic unit price clear enable 4 SETTING OF PARAMETERS 4 1 ENTER SETTING M...

Страница 9: ...VE key to select press TARE key to sure F6 INIT ZERO Not available F7 RE ZERO Not available F8 SCSIUE TARE Not available F9 A D COUNTS Displays the A D counts F10 cntry Not available F11 Fractn Set ha...

Страница 10: ...klight setting and operate Never use any charger or battery which is damaged Do not short circuit the battery Accidental short circuiting can occur when a metallic object coin clip or pen causes direc...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: