Cely PS-50 Series Скачать руководство пользователя страница 5

Series PS-50/60

49-MCEPS56EN03

USER´S MANUAL

1

1. INTRODUCTION

NOTE: These scales are not allowed for the uses mentioned in paragraph 2a of the article 1

st

 of the Directive

90/384/CE, therefore they are not valid for commercial transactions

The series PS-50/60 offers a precise, rapid and versatile only-weight scales for all uses. There are 3
weighing scales models in this range. The platform size is 190mm x 230mm, and the capacity ranges from 3
kg to 15 kg.

All keypads are sealed, membrane switches are colour-marked and displays are easy-to-read, large-sized
liquid crystal displays (LCDs). The LCDs are equipped with a backlight.

All units include tare, zero, change unit of weight, change division function.

Weighing scales series PS-60 is equipped with dust and liquid protection equivalent to IP-68.

2. SPECIFICATIONS

PS-50/60 SERIES

Model no.

PS-50/60-3

PS-50/60-6

PS-50/60-15

Range

3kg

6kg

15kg

Step

1g/0.5g

2g/1g

5g/2g

Resolution

1/3,000 or 1/6,000

Maximum tare

3kg

6kg

10kg

Minimum weight

20g/10g

40g/20g

100g/40g

Plate size

190mm x 230mm

Units of weight

kg

Optional functions

Beeper, backlight, stainless steel plate

3. INSTALLATION

3.1. GENERAL INSTALLATION

The scales should be placed on a firm, even surface.

Avoid extreme temperatures. Do not place the scales in direct sunlight or near air conditioning vents.

Avoid unstable tables. The tables and the ground should be firm and not vibrate. Do not place the scales
near vibrating machinery.

Avoid unstable electricity sockets. Do not use the scales near equipment with high electrical power
consumption such as soldering equipment or large motors.

Avoid high humidity that can cause condensation. Do not submerge the scales in water.

Avoid draughts such as those from fans or open doors. Do not place the scales near open windows.

Keep the scales clean.

Do not stack anything on the scales when they are not in use.

Содержание PS-50 Series

Страница 1: ...Ref 49 MCEPS56EN03 Rev 03 PS 50 60 ONLY WEIGHT SCALES User s Manual...

Страница 2: ......

Страница 3: ...6 OPERATION 2 6 1 MANUAL ZERO SETTING 2 6 2 SETTING THE TARE 2 6 3 CHANGE UNIT OF WEIGHT 3 7 CONFIGURATION 3 7 1 ACCESS TO CONFIGURATION MODE 3 7 2 CALIBRATION 3 7 3 CHANGE OF STEP 3 7 4 VERIFICATION...

Страница 4: ......

Страница 5: ...Model no PS 50 60 3 PS 50 60 6 PS 50 60 15 Range 3kg 6kg 15kg Step 1g 0 5g 2g 1g 5g 2g Resolution 1 3 000 or 1 6 000 Maximum tare 3kg 6kg 10kg Minimum weight 20g 10g 40g 20g 100g 40g Plate size 190mm...

Страница 6: ...net weight mode Bat Lo low battery indicator Charge the battery when this indicator lights up Kg current unit of weight is kgs Lb current unit of weight is lbs 6 OPERATION 6 1 MANUAL ZERO SETTING Pre...

Страница 7: ...plate is empty and when the STABLE indicator is activated press again The display will show the calibration weight Press to select a calibration weight in kg Ex A0 2 A1 4 A2 6 After selecting the wei...

Страница 8: ...mode the display will show F0 CAL Press five times and the display will show F5 oFF Press to enter then press to change the time until entering in sleep mode options oN 3 5 10 and 20 minutes Press and...

Страница 9: ...many different factors including the configuration of the backlight and operation Never use a damaged battery charger or battery Never short circuit the battery An accidental short circuit may occur i...

Страница 10: ...ched on when was pressed Remove the weight from the scales and try again Use to set the display to zero If the problem continues contact your distributor or CELY for assistance Err 6 A D out of range...

Страница 11: ...The aforementioned manufacturer declares that the apparatus described herein complies with the requirements contained in Directive 89 336 CEE and 73 23 CEE and where applicable to the following harmon...

Страница 12: ......

Страница 13: ......

Страница 14: ......