Cellphone-Mate SureCall CM2100 Скачать руководство пользователя страница 3

                                                Cellphone-Mate  Inc. 
                                                CM2100  62dB  Manual 

 

          NOTE: Keep the separation distance between the inside and outside antennas

 

to at least 75 ft apart to avoid RF oscillation. 

If not, then the amplification gain must be reduced with gain control switches on both sides of the unit for uplink and downlink.   

 

STEP 5.    Connect the Power Cord.   

STEP 6.    Turn the Power Switch on 

 

Warning:    To prevent damage to the Amplifier, before you plug in the Amplifier to an AC power outlet, 

please  make  sure  that  both  sides are  already  connected  with  the  cables  from  both  the  outdoor  and 

indoor antennas.   

 

WARNING: after the power is turned ON, and before making any cellular phone calls, if the 

warning light is ON, oscillation is happening.    POWER OFF immediately, then reduce both 

the uplink gain and downlink gain via the gain control switches on the side panel, or further 

increase separation distance between the two antennas, or do both until the power warning 

light is not ON when you are not making cellular phone calls.   

 

Note: 1. Power lights will always be on after you power up.     

 

STEP 7. After solving all oscillation problems, users can make cell phone calls to test how the repeater system works, adjusting 

the gain as needed.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power 

Switch 

Power Cord 

Uplink Gain Control Switches 

N Connector for Indoor 

Power Light 

Warning Light 

Downlink Gain Control Switches 

Отзывы: