background image

                                                       

 

                       

 

- 12 -

 

 

Fig. 6 System Test 

 
 

Test Number 

Test Type 

Description 

1 cooling 

1-on; 

0-off 

2 fan 

1-on; 

0-off 

 

3) Clock Setting 

 

1. Enter the system setup and set 670 = 0 to unlock screen, then exit. 
2. Press CLOCK key; press UP/DOWN keys to change clock. 
3. Press DONE key to exit. 
4. Enter the system setup and set 670 = 2 to lock screen, then exit. 

 

4) Temperature Setting 

 

1. Enter the system setup and set 670 = 0 to unlock screen, then exit. 
2. Press UP/DOWN keys to modify temperature. 
3. Enter the system setup and set 670 = 2 to lock screen, then exit. 
 

5)  Remote Air Sensor 

 

Enter the system setup and set 340 = 3, then exit 

 

6) Humidity Display 
 

It only displays the humidity where the thermostat is installed. The humidity 
level is shown in the lower right corner of the screen. 
 

Содержание 1/2 Ton-DS

Страница 1: ...on Operation Care Manual CellarTec 1 3 Ton DS CellarTec 1 2 Ton DS CellarTec 3 4 Ton DS w ww ww w a ap pe ex xw wi in ne ec ce el ll la ar rs s c co om m w ww ww w c ce el ll la ar rt te ec c c co om...

Страница 2: ...Information 2 Features Specifications 3 Cellar Construction 5 Installer s Instruction 6 Temperature Control Humidity Adjustment 9 Service Guide 13 Electrical Wiring 19 Care Guide 26 User Troubleshooti...

Страница 3: ...2 Important Safety Information WARNING DO NOT USE A GROUND FAULT INTERRUPTER GFI A DEDICATED CIRCUIT IS REQUIRED 15 AMP FOR 1 3 Ton DS AND 20 AMP FOR 1 2 3 4 Ton DS...

Страница 4: ...environment becomes dry and humid These temperatures and humilities are optimized for long term storage of wine The DS ducted systems are designed for both outdoor and indoor installation Back curved...

Страница 5: ...CellarTec 1 3 TON DS 45X34X23 4500 380 1000 cu ft R134a 115V 60HZ 8A 140 CellarTec 1 2 TON DS 45X34X23 6500 490 1500 cu ft R134a 115V 60HZ 14A 170 CellarTec 3 4 TON DS 45X34X25 8500 750 2000 cu ft R1...

Страница 6: ...ature surrounding the enclosure shall not exceed the temperature of the enclosure by more than 25 F No enclosure wall shall receive direct sun or strong wind Lighting shall be of low wattage with a ti...

Страница 7: ...ady for use only after a certified refrigeration technician has properly installed the system Proper installation is critical Apex can only warrant the quality of the components The installation of th...

Страница 8: ...the next step Connect wires in the outlet box of the condensing unit to the power lines Connect wires in the outlet box of the evaporator unit to the temperature controller and then connect the contro...

Страница 9: ...UCT DRAIN LINE CellarTec 1 3 TON DS 8 7 8 OD CellarTec 1 2 TON DS 10 7 8 OD CellarTec 3 4 TON DS 10 7 8 OD 7 Unit Operating Turn on the fan speed control Adjust thermostat temperature setting CAUTION...

Страница 10: ...required to reach the desired temperature will vary depending on the quantity of bottles temperature setting and surrounding temperature Allow 24 hours to stabilize the temperature for each new temper...

Страница 11: ...side of the center blank key for approximately five seconds until screen matches the screen below 3 Press UP DOWN advance keys to select setup number press UP DOWN change keys to change settings 4 Pre...

Страница 12: ...re Display 0 fahrenheit 1 celsius 0330 Daylight Savings 0 off 1 on 0340 Remote Air Sensor 0 no 3 indoor 0380 Indoor Dehumidification 0 no 0580 Min Compressor Off 5 five minutes off 0610 Min Cool Temp...

Страница 13: ...system setup and set 670 2 to lock screen then exit 4 Temperature Setting 1 Enter the system setup and set 670 0 to unlock screen then exit 2 Press UP DOWN keys to modify temperature 3 Enter the syst...

Страница 14: ...from flooding back to the compressor and aid oil returning to the compressor Charge the system after pipe brazing leak testing and evacuating Liquid must always be charged into the hide side It may us...

Страница 15: ...r suction pressure by turning the hex nut 5 16 counter clockwise Fig 7 Liquid Filter Fig 8 Sight Glass Fig 9 Expansion Valve The line sizes and refrigerant charges are listed as follows MODEL LIQUID L...

Страница 16: ...ceiver Discharge Compressor Suction 3 Liquid Line Suction Line 4 Pressure Control 3 Use of the adjustable pressure control if applicable for pump down Suction pressure setting Cut out 5 psig Cut in 25...

Страница 17: ...Fig 12 Single Adjustable Pressure Control B Dual Control Fig 13 Dual Adjustable Pressure Control 4 Use of the encapsulated low pressure control if applicable Fixed suction pressure setting Cut in 32...

Страница 18: ...h subcooling d High to normal suction pressure and high head pressure Low subcooling e High suction pressure and high head pressure Low subcooling f High suction pressure and high head pressure High s...

Страница 19: ...pansion valve restricted m Both evaporator and condenser restricted n Liquid line restricted before receiver o Condenser restricted 8 Condensing Unit Troubleshooting Unit not running a Incorrect power...

Страница 20: ...E FOR THERMOSTAT AND SENSOR IF EQUIPPED WITH LOW AMBIENT CONDITION KIT USE LOW AMBIENT TEMPERATURE WIRING DIAGRAMS TURN OFF THE COMPRESSOR BEFORE POWER THE CONDENSING UNIT ONLY TURN ON THE COMPRESSOR...

Страница 21: ...20 Fig 16 CellarTec 1 3 Ton DS Electrical Wiring Diagram...

Страница 22: ...21 Fig 17 CellarTec 1 2 Ton DS Electrical Wiring Diagram...

Страница 23: ...22 Fig 18 CellarTec 3 4 Ton DS Wiring Diagram...

Страница 24: ...23 Fig 19 Low Ambient Temperature CellarTec 1 3 Ton DS Electrical Wiring Diagram...

Страница 25: ...24 Fig 20 Low Ambient Temperature CellarTec 1 2 Ton DS Electrical Wiring Diagram...

Страница 26: ...25 Fig 21 Low Ambient Temperature CellarTec 3 4 Ton DS Wiring Diagram...

Страница 27: ...need to be cleaned at least every 6 months Unplug the system or disconnect power Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty Plug cooling system or re...

Страница 28: ...re is 57 F and then the wine temperature is around 57 0 5 F The air is light enough to change so quickly that it maintains relatively constant average temperature that would prevent wine bottle temper...

Страница 29: ...fresh air intake side c Check for excessive size d Check for installation location or increase setting e Clean condenser 7 Evaporator freezing up a Evaporator air flow restriction b Unit not stopping...

Страница 30: ...high ambient temperatures or airflow restriction d Malfunctioning components a Add support to improve installation b Check fans cabinet washers tubing contact and loose screws c Check for airflow bloc...

Страница 31: ...30 Customer Support If you still have problems please contact us at Apex 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info groupapex com...

Страница 32: ...ress or implied including any of fitness for a particular purpose In no event shall APEX be responsible for any consequential damages what is so ever Any modification of APEX products shall void this...

Страница 33: ...LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED INCLUDING BUT NO...

Отзывы: