CellarPro 3000Scm Скачать руководство пользователя страница 1

 

   

 

 

 

 

V3.3.16   

 

 
 

 

Control the Elements 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Split Ceiling Mount 

Refrigeration Systems 

Owner’s Manual 

Содержание 3000Scm

Страница 1: ...V3 3 16 Control the Elements Split Ceiling Mount Refrigeration Systems Owner sManual...

Страница 2: ...ellarPro Cooling Systems 1445 N McDowell Blvd Petaluma CA 94954 707 794 8000 Email info cellarprocoolingsystems com Website www cellarprocoolingsystems com IMPORTANT WARRANTY INFORMATION FOR YOUR SPLI...

Страница 3: ...t e n t s I Package Contents 4 II Specifications Cut Sheets and Cellar Construction 5 III Installation Instructions 10 IV Operating Instructions 43 V Troubleshooting 47 VI Limited Warranty 52 VII War...

Страница 4: ...EMOTE DISPLAY KIT 1 REMOTE DISPLAY LEADWIRE 10 FT SIGHT GLASS 1 FILTER DRIER 1 6000Scm 8000Scm BOX 1 BOX 3 DESCRIPTION QTY DESCRIPTION QTY PRIMARY EVAPORATOR 1 CONDENSING UNIT CEILING MOUNT BOLT 8 FEN...

Страница 5: ...35 1 x 18 8 x 6 5 55 9 3 6000Scm 2 35 1 x 18 8 x 6 5 110 14 7 8000Scm 2 35 1 x 18 8 x 6 5 110 16 3 Condensing unit Indoor Condensing unit Outdoor Model Dimensions W x D x H inches Weight lbs Dimension...

Страница 6: ...6 V3 3 16 Evaporator Cut Sheets...

Страница 7: ...7 V3 3 16 Condensing Unit Cut Sheets...

Страница 8: ...face mounted fixtures are recommended over recessed lighting which can allow air to leak into the cellar It is important that all walls joints doors and windows electrical outlets and or switches pipe...

Страница 9: ...the Cellar Evaporator Air Intake When the warm air passes across the evaporator coils heat is removed from the air and the resulting cold air is exhausted into the cellar To ensure proper airflow min...

Страница 10: ...h air to the space suggested 600CFM A minimum of 12 of open air space is required in front of the condenser coils Indoor units can be installed with the optional outdoor hood if additional mechanical...

Страница 11: ...11 V3 3 16 Evaporator Mounting Detail...

Страница 12: ...3 16 Dual Evaporator Mounting Options 6000Scm and 8000Scm models require two evaporators to be mounted in the cellar These may be mounted in either of the two orientation options shown in the drawing...

Страница 13: ...re available in the top panel for connections to pass through the cellar ceiling and in the right side panel for connections running along the interior cellar ceiling The type of connection by knockou...

Страница 14: ...16 Condensate Drain Line Each evaporator has an internal integrated condensate pump with 25 feet of PVC drain tubing This tubing should be routed to a suitable drain according to the following design...

Страница 15: ...water level in the evaporator cover reaches a depth of 5 8 and shuts off when the water level reaches 3 16 The pump will activate an overflow alarm at a level of 1 indicated by CA on the temperature c...

Страница 16: ...ed circuit breaker non GFI is recommended for 3000 4000S Sh Scm systems 3 A 25 amp dedicated circuit breaker non GFI is recommended for 6000 8000S Sh Scm systems 2 6000Scm and 8000Scm systems are conf...

Страница 17: ...d the Evaporator turns off the LLSV closes causing the system to pump down until the low pressure switch shuts off the Condensing unit When the Evaporator turns on the LLSV opens causing the suction p...

Страница 18: ...18 V3 3 16...

Страница 19: ...nit When the controller calls for cooling both of the LLSV open causing the suction pressure to rise and activate the Condensing unit Field power wiring is connected to the Primary Evaporator and Cond...

Страница 20: ...20 V3 3 16...

Страница 21: ...21 V3 3 16 6000Scm Wiring Diagrams Option A Dual Power Valve Control Page 1 of 2...

Страница 22: ...22 V3 3 16 6000Scm Wiring Diagrams Option A Dual Power Valve Control Page 2 of 2...

Страница 23: ...23 V3 3 16 8000Scm Wiring Diagrams Option A Dual Power Valve Control Page 1 of 2...

Страница 24: ...24 V3 3 16 8000Scm Wiring Diagrams Option A Dual Power Valve Control Page 2 of 2...

Страница 25: ...ead to Evaporator terminal N Connect power ground to grounding lug on Evaporator The Condensing Unit is powered by connecting it to the Evaporator is follows 3 on the Evaporator to L1 on the Condensin...

Страница 26: ...26 V3 3 16 3000 4000Scm Wiring Diagram Option B Single Power Electronic Control...

Страница 27: ...mary Evaporator as follows Secondary Evaporator Field Interconnect Wiring from Primary Evaporator Interconnect power leads to terminals 18 20 22 and 26 Interconnect 18 2 thermostat wiring to terminals...

Страница 28: ...28 V3 3 16 6000Scm Wiring Diagram Option B Single Power Electronic Control Page 1 of 2...

Страница 29: ...29 V3 3 16 6000Scm Wiring Diagram Option B Single Power Electronic Control Page 2 of 2...

Страница 30: ...30 V3 3 16 8000Scm Wiring Diagram Option B Single Power Electronic Control Page 1 of 2...

Страница 31: ...31 V3 3 16 8000Scm Wiring Diagram Option B Single Power Electronic Control Page 2 of 2...

Страница 32: ...ing Unit should be piped according to the following piping schematic Piping Legend 1 Liquid connection location 2 Hermetic liquid line filter drier shipped loose Install with directional flow arrow as...

Страница 33: ...unit suction access valve located off a tee on the compressor shell process tube 12 Field provided dual evaporator liquid line tee Required on 6000 8000Scm only 13 Field provided dual evaporator sucti...

Страница 34: ...1 2 1 2 5 8 5 8 8000S Scm 3 8 5 8 5 8 5 8 7 8 Notes 1 Line lengths are expressed in equivalent feet actual run length fitting allowances 3 Use only dehydrated refrigeration service tubing and refrige...

Страница 35: ...rap as shown to prevent liquid migration to the compressor during the off cycle For dual evaporator system install inverted suction traps on each evaporator to prevent liquid migration between evapora...

Страница 36: ...gration to the compressor during the off cycle For dual evaporator system install inverted suction traps on each evaporator to prevent liquid migration between evaporators while running and install an...

Страница 37: ...porator system install inverted suction traps on each evaporator to prevent liquid migration between evaporators while running and to prevent liquid migration to the compressor during the off cycle Pi...

Страница 38: ...ssure holds proceed to the next step otherwise locate and repair the leak and repeat this step 4 Evacuate the system to a minimum of 500 microns It is important to pull a vacuum though both the high a...

Страница 39: ...l the subcooling is within specifications 2 Too much refrigerant If the suction superheat is below 20 F remove refrigerant until the superheat is above this minimum limit 9 Optional It should not be n...

Страница 40: ...ta Sheet which initiates the warranty Do not overcharge or use refrigerant with additives Remember that bubbles in a sight glass may be caused by a restriction as well as a shortage of refrigerant A p...

Страница 41: ...4 93 40 1 93 3 05 3 74 5 14 45 2 01 3 25 3 95 5 44 50 2 09 3 45 4 15 5 65 55 2 16 3 65 4 36 5 86 60 2 24 3 85 4 56 6 08 65 2 32 4 05 4 76 6 29 70 2 40 4 25 4 97 6 51 75 2 48 4 45 5 17 6 72 80 2 56 4...

Страница 42: ...entially will produce buckets of water Without access to cool air either because of improper ventilation or because the environments is too hot the cooling unit will be unable to maintain proper tempe...

Страница 43: ...ed moved and or shipped in the upright position Be careful when turning the unit on its side The unit NEVER should be turned upside down Temperature Control CellarPro cooling units are designed to tur...

Страница 44: ...control the cellar by liquid temperature rather than air temperature inside the cellar Disconnecting the probe will automatically return the control to air temperature When using a bottle probe in li...

Страница 45: ...ading warm bottles in the cabinet Auto Defrost Mode The cooling unit has a factory default defrost cycle that initiates every 16 hours for 20 minutes When the cooling unit is in auto defrost mode the...

Страница 46: ...ry preset ENERGY SAVINGS MODE DIFFERENTIAL The factory preset for this setting is 4 This setting controls the Temperature Differential for the Energy Savings Mode The recommended range for this settin...

Страница 47: ...to run continuously To reduce cycle times 1 Remove any obstructions to air flow to or from the unit 2 Check to make sure the condenser coil is clean 3 Increase the supply of cool air to the space outs...

Страница 48: ...ck for loose wires and reconnect Low pressure switch is open On Valve control systems make sure solenoid is energized Jumper out switch to check for a faulty switch and replace if necessary Note that...

Страница 49: ...e power Power supply to fan interrupted loose wire Inspect for loose fan wiring and reconnect Fan capacitor check for loose wires or out of spec capacitance Reconnect loose wires or replace capacitor...

Страница 50: ...op section Condensing unit never shuts off System is wired incorrectly Locate correct wiring diagram for Electronic or Valve controlled system trace wiring and correct If a Valve control system the lo...

Страница 51: ...The cooling unit enters a timed auto cycle mode until Probe 1 is repaired or replaced In this mode the cooling unit will turn on for 12 minutes and off for 8 minutes Please call CellarPro at 877 726...

Страница 52: ...reinstalling the cooling unit from the wine cellar The limited warranty applies only to cooling units purchased from the factory or an authorized dealer Damage caused by others or by any cause beyond...

Страница 53: ...Condensing Unit Model Line set Length ft Condensing Unit Serial Liquid line diameter OD Evaporator Model Suction line diameter OD Evaporator Serial Power to Condensing Unit Check One ____From Evapora...

Отзывы: