background image

Page 4 | 1-855-235-5271

CX

 040418

NOTE: CellarCool units are manufactured in the USA and tested prior to shipment. 

Please leave the CellarCool unit in its original box until you are ready for installation. This will allow you to move the product 

safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions.  
             TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit. 

cx3300 and cx4400

Accessory kit #1: 

• (1) CellarCool CX Series owner’s

manual

• (2) Mounting flanges
• (2) Magnetic deflectors for airflow

control

• (18) Anti-microbial pan tabs
• (1) Drain line brush

Accessory kit #2:

• (8) #6 x 13/4" hex washer head screws
• (6) 1/2" pan-head screws
• (1) 1/2" ID plastic tubing (10 feet)
• (2) Pieces of insulation foam (20")
• (2) Pieces of insulation foam (17")

RECEIVING AND INSPECTING THE UNIT

Upon receiving your CellarCool unit: 

• Lift only at the designated hand-hold locations on the shipping container, or fully support the unit from underneath. A

shipment may include one or more boxes containing accessories.

• Inspect the packaging for any obvious signs of damage or mishandling before opening the container.
• Note any discrepancies or visual damage on the bill of lading before signing.
• Place the box containing the CellarCool unit on a tabletop to prepare it for testing prior to installation.
• Sit unit upright for 24 hours.
• Review the packing slip to verify the package’s contents.
• Check the model number to ensure it is correct.
• Check that all factory options ordered are listed.
• Check the box for the following:

Electrical Outlet 

Power surges and spikes can damage sensitive electrical equipment. CellarCool recommends plugging the unit into a surge 

protector or power conditioner in order to protect your system. As outlined in our terms and conditions, power surges and spikes 

are not covered under warranty.

Do not use a GFI (ground fault interrupter) with this product. 

Testing Unit 

Carefully remove your CellarCool unit from the box. Place the CellarCool system on a tabletop to prepare it for installation and  

testing. Plug system into a live electrical outlet and turn it on. The system may take up to 10 to 15 minutes before all four fans are  

running, cold air is coming out on the cellar side, and hot air is coming out on the exhaust side. Once the operation has been tested, 

turn the unit off and unplug it from the electrical outlet.* 

NOTE: If the system does not seem to be fully functional after 15 minutes, please refer to the Troubleshooting Guide on page 19.

Units weigh 55-101 pounds and are cumbersome for one person to carry.  We recommend that you get someone else to help you 

during the installation process. NEVER LAY UNIT ON ITS SIDE.

cx8800

Accessory kit #1: 

• (1) CellarCool CX Series owner’s

manual

• (2) Mounting flanges
• (2) Magnetic deflectors for airflow

control

• (18) Anti-microbial pan tabs
• (1) Drain line brush

Accessory kit #2:

• (8) #6 x 13/4" hex washer head screws
• (6) 1/2" pan-head screws
• (1) 1/2" ID plastic tubing (10 feet)
• (2) Pieces of insulation foam (20")
• (2) Pieces of insulation foam (17")

cx2200

Accessory kit #1: 

• (1) CellarCool CX Series owner’s

manual

• (2) Mounting flanges
• (2) Magnetic deflectors for airflow

control

• (18) Anti-microbial pan tabs
• (1) Drain line brush

Accessory kit #2:

• (8) #6 x 13/4" hex washer head screws
• (6) 1/2" pan-head screws
• (1) 1/2" ID plastic tubing (10 feet)
• (2) Pieces of insulation foam (20")
• (2) Pieces of insulation foam (17")

Содержание cx2200

Страница 1: ...CX SERIES OWNER S MANUAL cx2200 cx3300 cx4400 cx8800...

Страница 2: ...not responsible for printing or clerical errors CellarCool reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vi...

Страница 3: ...tallation Airflow Control 9 Preparing the Installation Location 10 Preparing the Unit for Installation 11 Installing the System 11 Drain Line 13 System Operation 14 Controller Functions 15 Wiring Sche...

Страница 4: ...ool cooling unit is a specialized refrigeration unit designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines It is...

Страница 5: ...of the cellar over time by cycling cooler air throughout Test the unit prior to installation 5 You are required to install a drain line to remove condensation from the unit 6 The CellarCool unit is in...

Страница 6: ...utlet Power surges and spikes can damage sensitive electrical equipment CellarCool recommends plugging the unit into a surge protector or power conditioner in order to protect your system As outlined...

Страница 7: ...5 CX SERIES QUICK REFERENCE GUIDE Front Side View Rear Side View Controller Power cord front location standard ON OFF switch for 4400 8800 models only Power cord rear location optional Air sensor Rear...

Страница 8: ...s parts and labor 5 years compressor Sizing the Unit to the Room The specification chart will provide information on the unit s cooling capacity There are circumstances in which a cellar design may re...

Страница 9: ...ly use CellarCool products It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months Standard fiberglass or rigi...

Страница 10: ...rtion of the unit NOTE High humidity significantly increases the heat load on the cooling system Any break in the vapor barriers a cut a nail hole overlapping etc will cause a moisture leak and must b...

Страница 11: ...will best suit your installation NOTE Do not cover both of the openings on the same side of the unit for any reason This will cause cooling issues and premature failure NOTE Do not cover both of the...

Страница 12: ...rough your studs when you have a clear understanding what is inside the wall Now make the second horizontal cut from stud to stud on the line below the first cut Once the horizontal lines have been cu...

Страница 13: ...ellar Note If you use decorative moulding it should be attached to the walls and never to the cooling unit itself The moulding itself should be removable incase the unit needs servicing Applying Insul...

Страница 14: ...n each side of the side of the unit you will notice 6 indents these mark two different installation depths Select one of the two mounting depths and attach each mounting bracket to the unit with the s...

Страница 15: ...s important that the drain line tube be properly connected and used to prevent leakage and other problems associated with excess condensation Failure to use the condensation drain line tube will void...

Страница 16: ...has reached the setpoint to allow the pressure in the refrigeration unit to equalize prior to starting the compressor Anti Frost Cycle defrost After two hours of compressor operation the controller w...

Страница 17: ...utton once more Use the UP and DOWN ARROW buttons in order to change the value until the desired setpoint is reached Hold the set button for approximately 5 seconds to enter the CPSM Customer Preferen...

Страница 18: ...snowflake symbol will not be lit 2 Add heat to the room until the wine reaches the desired temperature Press and hold the SET button for approximately 5 seconds to enter the CPSM menu Use the DOWN AR...

Страница 19: ...www cellarcool com Page 17 CX SERIES cx2200 cx3300 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Страница 20: ...Page 18 1 855 235 5271 CX 040418 cx4400 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Страница 21: ...www cellarcool com Page 19 CX SERIES cx8800 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Страница 22: ...Page 20 1 855 235 5271 CX 040418 NOTES...

Страница 23: ...ine voltage is incorrect rating for unit Check line voltage to make sure there is 110V 120V Room at setpoint Lower setpoint Thermostat not calling for cooling Lower setpoint Faulty thermostat or wirin...

Страница 24: ...Solution Lack of airflow heat exhaust outer room Make sure fan is unobstructed clean evaporator if necessary The unit is undersized for the room Purchase correctly sized unit Evaporator fan runs but...

Страница 25: ...USING INTERIOR DRAIN LINE Insert supplied drain line brush from this end Drop pan tab into drip tray through access door ACCESS DOOR CX2200 ACCESS DOOR CX3300 4400 8800 ACCESS DOOR SCREWS REAR OF UNIT...

Страница 26: ...arCool Customer Service 1738 E Alpine Ave Stockton CA 95205 www cellarcool com Email support cellarcool com Tech Support Customer Service 1 800 343 9463 Sales Sizing Assistance 1 855 235 5271 Fax 209...

Страница 27: ...d in the event the Product is not repairable in the field cover normal ground freight charges within the continental United States for the repair or replacement of the Product B Five 5 Year Compressor...

Страница 28: ...arCool Owner s Manual and thereafter the End User must follow the required installation use and maintenance procedures set forth by CellarCool in CellarCool s Owner s Manual The Owner s Manual is ship...

Страница 29: ...t 1738 East Alpine Avenue Stockton California 95205 8 Miscellaneous Terms and Conditions A Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a...

Страница 30: ...343 9463 or please send a letter via U S Mail to Customer Service CellarCool Corporation 1738 E Alpine Ave Stockton CA 95205 Email support cellarcool com Web www cellarcool com B Technical Assistance...

Страница 31: ...CellarCool 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www cellarcool com...