ALARM CODES
CPSM (CUSTOMER PREFERENCE SELECTION MODE)
Message
Cause
Solution
“E1”
Faulty air-sensing probe
Contact Customer Service at 1-800-343-9463.
“AH1”
The air probe is sensing
a temperature that is 10°
above the setpoint
1. Allow time for the wine to reach the desired temperature.
2. Make sure all windows and doors are closed and have a proper seal.
3. Follow the procedures in the pre-installation instructions to test the unit for proper
cooling.
“AL1”
The air probe is sensing
a temperature that is 10°
below the setpoint
1. Make sure unit is not in cooling mode. (The snowflake symbol will not be lit.)
2. Add heat to the room until the wine reaches the desired temperature.
Press and hold the SET button for approximately 5 seconds to enter the CPSM menu.
Use the DOWN ARROW button to access the following parameters.
PA2
No adjustable settings in this parameter.
tab
No adjustable settings in this parameter.
Rel
No adjustable settings in this parameter.
LOC Change this parameter from “n” to “y” to lock the keyboard from changes to the setpoint.
CA1 Increase or decrease the temperature reading of the air sensor. (This process recalibrates to
the sensor.) Increasing the value by 1 means an increase in the temperature reading by 1
degree. This parameter can be ad- 12 degrees. If needed: Adjust this setting to match
your temperature sensor located inside of the cellar.