Cell2 SAF101H Скачать руководство пользователя страница 6

Wire Size and Termination

 – The “AMPLIFIER CONNECTIONS” diagram shows the 

minimum size of the wires used for each connection, along with recommended lead 

color. If the wire is longer than 10 ft., use the next larger size.

SW1 (SW1) Output Connection

 – Connect to auxiliary device power up to 0.2 Amps 

max. or use as Lightbar function activation switch.

SW2 (SW2) Output Connection

 – Connect to auxiliary device power up to 0.2 Amps 

max. or use as Lightbar function activation switch.

SW3 (SW3) Output Connection

 – Connect to auxiliary device power up to 0.2 Amps 

max. or use as Lightbar function activation switch.

SW4 (LIGHT) Output Connection

 – Connect to auxiliary device power up to 0.2 Amps 

max. or use as Lightbar function activation switch.

IGN (Ignition) Input Connection

 – This serves as the power switch for the entire unit. 

Connect to a positive circuit controlled by the vehicle ignition switch, usually a terminal at 

the vehicle fuse panel. It is not recommended to make permanent power connection as 

this may drain battery.

RAD (Radio) Input Connection

 – Connect to radio output terminals or its speaker.

HORN Input Connection

 – The Horn Ring Transfer input allows activation by an 

external source of the Air Horn function.

Speaker Output Connection

 – Both connections must be used. Two speakers may be 

connected in parallel.

WARNING:

 Ensure that all wires are firmly secured onto the block plug, and plug is firmly 

secured onto the siren.

Electrical connections to the unit are made by using block plugs and screw terminals. 

Route all wiring to the siren and secure onto block plug terminals, then plug onto the 

siren. The plug can be easily removed without unwiring when the unit requires servicing. 

The power supply for the fused amplifier (12-P plug) must be capable of delivering peak 

currents up to12A for adequate short circuit protection and proper operation. It is 

recommended to wire directly to the vehicle battery.

ELECTRICAL CONNECTIONS

Use wires that are capable of handling the required current. Route the wires properly to 

prevent wear, overheating and interference with air bag deployment. Ensure that all 

connections are tight and double check wiring before connecting to the vehicle battery.

WIRING

CONNECTIONS

 

Recommended

Wire Size

Amps

Size

5-10

#16

10-15

#14

15-25

#12

25-40

#10

40-60

#8

Use next larger size

if longer than 10ft.

The leads and 

recommended 

colours shown 

are user-supplied.

NOTE: 

The controller is shipped without any button 

plates or decals installed. Place decal onto button 

plates, then install plates onto each button.

Hand held controller

Button Decal

MAN

1

Button Plate

#14 AWG BLK 

12-P Terminal Block Plug

#18 AWG BRN x2

IGN (Ignition) Input Connection

#22 AWG ORG 

Unit Enable (like an ON/OFF switch) 

Connect to positive circuit (fuse panel) 

controlled by ignition or other switch

#14 AWG RED

RAD (Radio) Input Connection

#22 AWG GRAY x2 Connect to output 

jack, terminals, or speaker of radio

#22 AWG YELLOW

HORN Input Connection

+VDC

HORN

+VDC

HORN

+VDC Switching example

Load SW1 0.2 Amps Max.

Load SW2 0.2 Amps Max.

Load SW3 0.2 Amps Max.

Load SW4 0.2 Amps Max.

Automotive Type Fuse

12VDC Use15A

24VDC Use10A

SW1

SW2

SW3

SW4

+VDC

-GND

IGN

RAD

RAD

HORN

SPK-

SPK+

SAF101H Siren_v.1.0

SAF101H Siren_v.1.0

- 4 -

- 5 -