D. Start/Reset:
1.
Place 2 pcs AAA 1.5V alkaline batteries according
to the polarities marked.
2.
LCD display will be switched on.
If there are any display or functional errors,
please remove the batteries for about 30 sec
to reset the thermostat.
3.
Temperature detection starts and LCD displays the
room temperature.
4.
will be flashing if Battery is LOW. Replace the
battery immediately.
5.
Defrost function is activated with
displayed
when temperature is 5°C or below.
Output will be ON @ Heat mode & OFF @ Cool
mode.
6.
LCD will display
Lo
if temperature is below 0°C,
7.
LCD will display
HI
if
temperature is above 40°C,
8.
Insert the receiver plug to power socket.
9
E. Operation Mode:
Press
key to switch between the 3 operation
modes below.
1. Program Mode
or
will be displayed
The thermostat controls the room temperature
according to the programs.
2. Temporary Override Mode
or
will be displayed
The thermostat controls the room temperature
according to the override temperature temporarily, and
returns to Program mode for the next Comfort / Econ
mode transition.
3. Permanent Override Mode
will be displayed
The thermostat controls the room temperature
according to the override temperature permanently.
10